L101-E1-05A (986758), страница 5
Текст из файла (страница 5)
To switch to twin timer operation, use the procedure given below. For details, refer to page 32.Power ONTimer/twin timer selection modeTimer/twin timerselectionRun mode1+Hold down for 1 smin. (See note.)Note: Thekey must be pressedbefore the 1 key.Switch from timer operation () totwin timer () operation using thekeys.Settings for Basic FunctionsSettings for basic functions can be performed with just the DIP switch.Be sure to set pin 1 to ON when using the DIP switch.12345678ONOFFItem1DIP switch settings enable/disable2OFFDisabledONEnabledOFF time range Refer to the table on the right.34ON time rangeRefer to the table on the right.6ON/OFF startmodeFlicker OFFstartFlicker ON start7Timer modeUPPin 2Input signalwidth20 msOFF time rangeOFFONOFF0.1 s to 999.9 sOFFON1 s to 9999 sONON0 min 01 s to 99 min 59 s58Pin 3OFFPin 40.01 s to 99.99 sPin 5ON time rangeOFFOFF0.01 s to 99.99 sDOWNONOFF0.1 s to 999.9 s1 msOFFON1 s to 9999 sONON0 min 01 s to 99 min 59 sNote: All the pins are factory-set to OFF.Easy Confirmation of Switch Settings Using IndicatorsThe ON/OFF status of the DIP switch pins can be confirmedusing the front display.
For details, refer to page 31.Note 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled.2. Changes to DIP switch settings are enabled when the power is turned ON. (Perform DIP switch settings while the power is OFF.)3. There is no DIP switch on the H5CX-L8@. For details on the setting methods, refer to page 27.4. When using time ranges that cannot be set with the DIP switch, all of the settings have to be made using the operation keys.
For detailson the setting methods, refer to page 27.Detailed SettingsAfter making DIP switch settings for basic functions, detailed settings (see note) can be added using the operation keys.For details, refer to page 27.Note: NPN/PNP input mode, display color, key protect level.26Multifunction Digital TimerH5CX-A/-L (Twin Timer Function)Settings for Advanced FunctionsSettings that cannot be performed with the DIP switch are performed with the operation keys.Power ONRun modeFor details on operations in run mode, refer to page 29.Note 1. If the mode is switched to the function setting mode during operation, operation willcontinue.2. Changes made to settings in function setting mode are enabled for the first time whenthe mode is changed to run mode. Also, when settings are changed, the timer is reset(time initialized and output turned OFF).(See note 1.)(See note 2.)The characters displayed in reverse video are the initial values.3 s min.3 s min.When performing settings with operation keys only, set pin1 of theDIP switch to OFF (factory setting).
If pin 1 of the DIP switch is setto ON, the setting items indicated bywill not be displayed.OFF timerangeSet the OFF time range using thesskeys.......shshsFor details, refer to Time Range List below.ON timerangeSet the ON timer range using thesskeys.......sFor details, refer to Time Range List below.Timer modeSet the timer mode using thekeys.Function setting mode(Elapsed (Remainingtime)time)ON/OFFstart modeSet the twin timer output mode using thekeys.(Flicker OFF (Flicker ONstart)start)Time Range ListDisplayInput signalwidthSet the input signal width using the(20 ms)keys.Set Value0.01 s to 99.99 s (default setting)0.1 s to 999.9 s(1 ms)1 s to 9999 sNPN/PNPinputSet the NPN/PNP input mode using thekeys.(NPN input) (PNP input)Only displayed for H5CX-A@ and H5CX-A11@ models.0 min 01 s to 99 min 59 s0.1 min to 999.9 min1 min to 9999 minDisplay colorSet the display color using thekeys.0 h 01 min to 99 h 59 min(Red) (Green) (Red-green) (Green-red)Displayed for terminal-block models (H5CX-A@) only.Key protectlevelSet the key protect level using the(KP-1)(KP-2)(KP-3)1 h to 9999 hkeys.(KP-4)(KP-5)Multifunction Digital Timer H5CX-A/-L0.1 h to 999.9 h0.001 s to 9.999 s(Twin Timer Function)27Explanation of FunctionsOFF Time Range (oftr) (Setting possible using DIPswitch.)Input Signal Width (iflt) (Setting possible using DIPswitch.)Set the time range for the OFF time in the range 0.000 s to 9,999 h.Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),and -- min -- s (99 min 59 s), however, can be made with the DIPswitch.
Use the operation keys if another type of setting is required.Set the minimum signal input width (20 ms or 1 ms) for signal, reset,and gate inputs. The same setting is used for all external inputs (signal, reset, and gate inputs). If contacts are used for the input signal,set the input signal width to 20 ms. Processing to eliminate chattering is performed for this setting.ON Time Range (ontr) (Setting possible using DIPswitch.)NPN/PNP Input Mode (imod)Set the time range for the ON time in the range 0.001 s to 9,999 h.Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s),and -- min -- s (99 min 59 s), however, can be made with the DIPswitch.
Use the operation keys if another type of setting is required.Select either NPN input (no-voltage input) or PNP input (voltageinput) as the input format. The same setting is used for all externalinputs. For details on input connections, refer to “Input Connections”on page 9.Timer Mode (timm) (Setting possible using DIP switch.)Display Color (colr)Set either UP (incremental) or DOWN (decremental) timer mode. InUP mode, the elapsed time is displayed, and in DOWN mode, theremaining time is displayed.Set the color used for the present value.Output OFFON/OFF Start Mode (totm) (Setting possible using DIPswitch.)Set the output mode. Set either flicker OFF start or flicker ON start.(For details on output mode operation, refer to “Timing Charts” onpage 30.)Output ONredRed (fixed)grnGreen (fixed)r-gRedGreeng-rGreenRedKey Protect Level (kypt)Set the key protect level.When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying thekey protect level (KP-1 to KP-5).
The key protect indicator is lit while the key-protect switch is set to ON.(See note)OFF ONNote: Factory-set to OFFKey protect indicatorLevelMeaningDetailsChanging mode(See note.)Switching displayduring operationReset keyUp/down keyKP-1(default setting)NoYesYesYesKP-2NoYesNoYesKP-3NoYesYesNoKP-4NoYesNoNoKP-5NoNoNoNoNote: Changing mode to timer/twin timer selection mode (28Multifunction Digital TimerMODE+11 s min.) or function setting mode (MODEH5CX-A/-L (Twin Timer Function)3 s min.).Operation in Run ModePresent valueSet the digits for the OFF set time using the correspondingkeys.Set the digits for the ON set time using the correspondingkeys.OFF set timePresent valueON set timePresent Value and OFF Set TimeThe present value is displayed in the main display and the OFF settime is displayed in the sub-display. “SET1” lights at the same time.Present Value and ON Set TimeThe present value is displayed in the main display and the ON settime is displayed in the sub-display.
“SET2” lights at the same time.Multifunction Digital Timer H5CX-A/-L(Twin Timer Function)29Timing ChartsTwin Timer OperationThe gate input is not included in the H5CX-L8@ models.Output mode toff: Flicker OFF startSustainedOutputTiming starts when the start signal goes ON.The status of the control output is reversed when timeis up (OFF at start).While the start signal is ON, the timer starts when thepower comes ON or when the reset input goes OFF.PowerStart signalBasic OperationGatePowerResetStart signal **inputControl outputOFF timeTimingONTimingOFFTimingONOutputUPON timeTimingdiagramTimingOFF*Normal output operation will not be possible if theON/OFF set time is too short.Set the value to at least 100 ms (contact outputtype).** Start signal input is disabled during timing.0OFF timeDOWNON time0Output mode ton: Flicker ON startSustainedOutputTiming starts when the start signal goes ON.The status of the control output is reversed when timeis up (ON at start).While the start signal is ON, the timer starts when thepower comes ON or when the reset input goes OFF.PowerStart signalBasic OperationGatePowerResetStart signal **inputControl outputOFF timeTimingONTimingOFFTimingONTimingOFFOutputUPTimingdiagram*Normal output operation will not be possible if theON/OFF set time is too short.Set the value to at least 100 ms (contact outputtype).** Start signal input is disabled during timing.ON time0OFF timeDOWNON time0Self-diagnostic FunctionThe following displays will appear if an error occurs.Main displaye1Sub-displayErrorOutput statusOFFCorrection methodSet value afterresetNot litCPUEither press the reset key or reset the No changepower supply.e2Not litMemory error (RAM)OFFReset the power supply.No changee2sumMemory error (EEP)(See note)OFFReset to the factory settings usingthe reset key.0Note: This includes times when the life of the EEPROM has expired.30Multifunction Digital TimerH5CX-A/-L (Twin Timer Function)■ Operation in Timer/Twin Timer Selection ModeSelect whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode.