or two, M4450 max.31.2 max.40±0.2P2CF-11-E (Finger Safe Terminal Type)Conforming to VDE0106/P100Eleven,M3.5 x 7.5 sems4.557.831.270 max.35.4Two, 4.5 dia.holes440±0.23050 max.Back Connecting SocketP3G-0831.2 max.Terminal Arrangement/Internal Connections(Bottom View)27 dia.45454.917Terminal Arrangement/Internal Connections(Bottom View)P3GA-1127 dia.4525.6454.516.36.2Finger Safe Terminal CoverConforming to VDE0106/P100Y92A-48G(Attachment for P3G-08/P3GA-11Socket)Twelve, 6.4 dia. holes3447.7 x 47.716.548 x 4824.6 27.647.4Multifunction Digital Timer H5CX-A/-L15Note: 1. Depending on the operating environment, the condition ofresin products may deteriorate, and may shrink or becomeharder.
Therefore, it is recommended that resin productsare replaced regularly.2. The H5CX’s panel surface is water-resistive (conforming toIP66) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internalcircuits. If, however, there is a possibility of oil being presenton the operator’s hands, use the Soft Cover. The Soft Coverensures protection equivalent to IP54F against oil.
Do not,however, use the H5CX in locations where it would come indirect contact with oil.Soft CoverY92A-48F1Hard CoverY92A-48Flush Mounting Adapter(provided with H5CX-A@ models)Y92F-30Waterproof Packing(provided with H5CX-A@ models)Y92S-29Note: Order the Flush Mounting Adapter separately if it is lost or damaged.Mounting TrackPFP-100N, PFP-50NNote: Use Waterproof Packing to provide a level of water protectionthat complies with NEMA4, UL Type 4X, or IP66 standards. Order the Waterproof Packing separately if it is lost or damaged.Depending on the operating environment, the WaterproofPacking may deteriorate, contract, or harden and so regular replacement is recommended.PFP-100N2167.3±0.154.54.515 252510251,000 (500)(See note.)1035±0.327±0.1535±0.325 *1512525 152525101,0002724110Note: The values shown in parentheses are for the PFP-50N.End PlatePFP-MSpacerPFP-S106.2161251.81501.811.534.844.31.310 M4 x 8pan headscrew1635.5 35.3Multifunction Digital Timer4.8H5CX-A/-L16.529.21.5Operating Procedures■ Setting Procedure GuideSettings for Timer OperationUse the following settings for all models except the H5CX-L8@.Refer to page 19 for the H5CX-L8@.When Using Basic Functions OnlyBasic Functions• Time range (0.001 s to 999.9 h,except 9999 h and 9999min)• Output mode (A, A-2, E, F)• Timer mode (UP/DOWN)• Input signal width (20 ms/1 ms)The settings can be performed easily with the DIP switch.➡For details on the setting methods, refer to page 18.12345678ONOFFWhen Using Other Time Ranges(9999 h, 9999 min) and OutputModes (A-1, A-3, b, b-1, d, and Z)When Using More Detailed Setting Items(Output Time, NPN/PNP Input Mode,Display Color, Key Protect Level)All the functions can be set with the operation keys.➡For details on the setting methods, refer to page 19.Setting for items other than the basic functions can beperformed with the operation keys.➡For details on the setting methods, refer to page 19.Note: At the time of delivery, the H5CX is set for timer operation.Settings for Twin Timer OperationUse the following settings for all models except the H5CX-L8@.Refer to page 27 for the H5CX-L8@.When Using Basic Functions Only••••Basic FunctionsTime range (0.01 s to 99 min 59 s)ON/OFF start mode(flicker OFF start/flicker ON start)Timer mode (UP/DOWN)Input signal width (20 ms/1 ms)The settings can be performed easily with the DIP switch.➡For details on the setting methods, refer to page 26.12345678ONOFFWhen Using Other Time Ranges(999.9 min, 9999 min, 99 h 59 min,999.9 h, 9999 h, 9.999 s)All the functions can be set with the operation keys.➡For details on the setting methods, refer to page 27.When Using More Detailed Setting Items(NPN/PNP Input Mode, Display Color, KeyProtect Level)Setting for items other than the basic functions can beperformed with the operation keys.➡For details on the setting methods, refer to page 27.Note: At the time of delivery, the H5CX is set for timer operation.Multifunction Digital Timer H5CX-A/-L17■ Operating Procedures (Timer Function)Settings for Basic FunctionsSettings for basic functions can be performed with just the DIP switch.Be sure to set pin 1 to ON when using the DIP switch.12345678ONOFFItem12OFFONDIP switch settings enable/disableDisabledEnabledTime rangeRefer to the table on the right.345Pin 2Pin 3Pin 4Time rangeONONON0.001 s to 9.999 sOFFOFFOFF0.01 s to 99.99 sONOFFOFF0.1 s to 999.9 sOFFONOFF1 s to 9999 sONONOFF0 min 01 s to 99 min59 sOutput modeRefer to the table on the right.OFFOFFON0.1 min to999.9 min7Timer modeElapsed time(UP)Remaining time(DOWN)ONOFFON0 h 01 min to99 h 59 min8Input signalwidth20 ms1 msOFFONON0.1 h to 999.9 h6Note: All the pins are factory-set to OFF.Pin 5Pin 6Output modeOFFOFFA mode (signal ON delay(I): power reset operation)ONOFFA-2 mode: (power ON delay (I): power reset operation)Easy Confirmation of Switch Settings Using IndicatorsOFFONThe ON/OFF status of the DIP switch pins can beconfirmed using the front display.
For details, refer to page 31.E mode (interval: powerreset operation)ONONF mode (accumulative:power hold operation)Note 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled.2.
Changes to DIP switch settings are enabled when the power is turned ON. (Perform DIP switch settings while the power is OFF.)3. There is no DIP switch on the H5CX-L8@. For details on the setting methods, refer to page 19.4. When using time ranges or output modes that cannot be set with the DIP switch, all of the settings have to be made using the operationkeys. For details on the setting methods, refer to page 19.Detailed SettingsAfter making DIP switch settings for basic functions, detailed settings (see note) can be added using the operation keys.For details, refer to page 19.Note: Output time, NPN/PNP input mode, display color, key protect level.18Multifunction Digital TimerH5CX-A/-L (Timer Function)Settings for Advanced FunctionsSettings that cannot be performed with the DIP switch are performed with the operation keys.Power ONRun modeFor details on operations in run mode, refer to page 21.Note 1. If the mode is switched to the function setting mode during operation,operation will continue.2.
Changes made to settings in function setting mode are enabled for thefirst time when the mode is changed to run mode. Also, when settingsare changed, the timer is reset (time initialized and output turned OFF).See note 1.See note 2.The characters displayed in reverse video are the default settings.3 s min.3 s min.When performing settings with operation keys only, set pin1 of theDIP switch to OFF (factory setting). If pin 1 of the DIP switch is setto ON, the setting items indicated inwill not be displayed.Set the time range using thekeys.Time rangess......shsFor details, refer to Time Range List below.Set the timer mode using thekeys.Timer mode(Elapsedtime)Output modeSet the output mode using theFunction setting mode(A)Output time(Remainingtime)(A-1)(A-2)(A-3)keys.(b)(b-1)(d)(E)Set each digit for the output time using the corresponding: Output hold/0.01 to 99.99 s(If the output time is set to 0.00,is displayed.)Displayed for modes A, A-1, A-2, A-3, b, and b-1 only.InputsignalSet the input signal width using thekeys.(F)(Z)keys.Time Range ListDisplaySet Value0.01 s to 99.99 s(default setting)0.1 s to 999.9 s(20 ms)(1 ms)1 s to 9999 sNPN/PNPinputSet the NPN/PNP input mode using thekeys.(NPN input) (PNP input)Only displayed for H5CX-A@ and H5CX-A11@ models.0 min 01 s to 99 min 59 s0.1 min to 999.9 min1 min to 9999 minDisplay colorSet the display color using thekeys.0 h 01 min to 99 h 59 min(Red) (Green) Red-green Green-redDisplayed for terminal-block models (H5CX-A@) only.Key protectlevelSet the key protect level using thekeys.0.1 h to 999.9 h1 h to 9999 h0.001 s to 9.999 s(KP-1)(KP-2)(KP-3)(KP-4)(KP-5)Multifunction Digital Timer H5CX-A/-L(Timer Function)19Explanation of FunctionsInput Signal Width (iflt) (Setting possible using DIPswitch.)Time Range (timr) (Setting possible using DIP switch.)Set the range to be timed in the range 0.000 s to 9,999 h.
Settings oftype ---- h (9,999 h) and ---- min (9,999 min) cannot, however, bemade with the DIP switch. Use the operation keys if these settingsare required.Set the minimum signal input width (20 ms or 1 ms) for signal, reset,and gate inputs. The same setting is used for all external inputs (signal, reset, and gate inputs). If contacts are used for the input signal,set the input signal width to 20 ms.
Processing to eliminate chattering is performed for this setting.Timer Mode (timm) (Setting possible using DIP switch.)NPN/PNP Input Mode (imod)Set either the elapsed time (UP) or remaining time (DOWN) mode.Select either NPN input (no-voltage input) or PNP input (voltageinput) as the input format.
The same setting is used for all externalinputs. For details on input connections, refer to “Input Connections”on page 9.Output Mode (outm) (Setting possible using DIP switch.)Set the output mode. The possible settings are A, A-1, A-2, A-3, b, b1, d, E, F, and Z. Only output modes A, A-2, E, and F can be setusing the DIP switch.
Use the operation keys if a different setting isrequired. (For details on output mode operation, refer to “TimingCharts” on page 22.)Display Color (colr)Set the color used for the present value.Output OFFOutput ONOutput Time (otim)redRed (fixed)When using one-shot output, set the output time for one-shot output(0.01 to 99.99 s). One-shot output can be used only if the selectedoutput mode is A, A-1, A-2, b, or b-1. If the output time is set to 0.00,hold is displayed, and the output is held.grnGreen (fixed)r-gRedGreeng-rGreenRedKey Protect Level (kypt)Set the key protect level.When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying thekey protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON.(See note)OFF ONNote: Factory-set to OFFKey protect indicatorLevelMeaningDetailsChanging mode(See note.)Switching displayduring operationReset keyUp/down keyKP-1(default setting)NoYesYesYesKP-2NoYesNoYesKP-3NoYesYesNoKP-4NoYesNoNoKP-5NoNoNoNoNote: Changing mode to timer/twin timer selection mode (20Multifunction Digital TimerMODE+11 s min.) or function setting mode (H5CX-A/-L (Timer Function)MODE3 s min.).Operation in Run ModeWhen Output Mode Is Not ZPresent valueSet each digit for the set value using the correspondingkeys.Set valueWhen Output Mode Z Is SelectedPresent valueSet each digit for the ON duty ratio using the corresponding(Thekeys for the 4th digit cannot be used.)keys.ON duty ratioPresent valueSet each digit for the cycle time using the correspondingkeys.Cycle timePresent Value and Set ValuePresent Value and Cycle Time (Output Mode = Z)These items are displayed when the power is turned ON.