NT support tool (V053-E1-1) (986753), страница 46
Текст из файла (страница 46)
11↓Create [Lamp 1] to [Lamp 5]↓Create image data for image lamp↓Create [Image Lamp]↓Create [Bar Graph 1]↓Create [Bar Graph 2]↓Create [Menu] button↓Create [Set] button↓Create [Alarm] button↓Create parent screen(screen No. 10, 11 as child screens)↓Creating the Set ScreenCreate new screen (screen No.
3)↓Set properties for screen No. 3↓Create screen title↓Create numeral input field of [Numeral Input 1]↓Create numeral input field of [Numeral Input 2]↓Create [Thumbwheel]↓(2)364Operation FlowSection 9-2(2)↓Create [Start] and [Stop] buttons↓Create [String Display] display field↓Create [Auto] button↓Create [Man.] button↓Create [Step] button↓Create [Reset] button↓Create [Menu] button↓Create [Monitor] button↓Create [Alarm] button↓Creating the Alarm ScreenCreate new screen (screen No. 4)↓Set properties for screen No. 4↓Create screen title↓Create alarm list↓Create [Menu] button↓Create [Set] button↓(3)365Operation FlowSection 9-2(3)↓Create [Monitor] button↓Create alarm library data↓Create numeric keys for pop-up window display↓Save the created data↓Download the created data366Creating the Sample Data9-3Section 9-3Creating the Sample DataThis section describes the operational procedure and data creation procedurestep by step according to the operation flow shown in 9-2 “Operation Flow”.Reference: The explanation in this section assumes that the default value of each object’sproperty is not changed since installation.9-3-1Starting up the Support ToolAt the start-up screen of Windows, double click the Support Tool icon to start theSupport Tool.
(Refer to 3-1 “Starting-up and Exiting the Support Tool”.)9-3-2[File] – [New]Select [File] in the main menu, then select [New] to create a new file.(Refer to 3-3-1 “Creating New Screen Data (Application) File”.)9-3-3Setting the PT ConfigurationAt the PT configuration setting dialog box, set the items as shown below.(Refer to 3-3-1 “Creating New Screen Data (Apprication) File”.PT TypeSystemPT ModelNT620C/625CPLC VendorOMRONFont TypeCP437CommentsSAMPLE DATAInitial Screen1Backlight OFFCheck mark set, 60minResume functionCheck mark not setNumber ofTable EntriesNumeral Table512String Table256Bit Memory Table256PrinterESC/PModeColourPrinter for PTHistory Setting Alarm (Use Ring Buffer)Check mark setBuzzerEnableCheck mark set, OnErrorKey InputCheck mark not setAfter setting the PT configuration items as indicated above, click on.367Creating the Sample Data9-3-4Section 9-3Setting Memory TablesSet the memory tables (numeral memory tables, character-string memory tables(string tables), and bit memory tables).
(Refer to section 7 “Memory Table Setting”.)Opening a table(1) Select [Tools] (menu bar) → [Table].Setting numeral memory tables(1) Make the numeral memory table settings as shown below.No.Value Initial WordsPC (PLC)AddressI/OCommentsRef00n1D00000Mtr: Num.disp.1––10n2D00001Mtr: Num.disp.2––20n1D00003Mtr: Trd.graph 1––30n1D00004Mtr: Trd.graph 2––40n1D00005Mtr:Bar graph 1––50n1D00006Mtr:Bar graph 2––––368100n2D00010Set:Num.input 1––110n2D00012Set:Num.input 2––120n1D00014Set:Thumbwheel––Creating the Sample DataSection 9-3Setting character string memory tables(1) Click on [String].(2) Make the character string memory table settings as shown below.No.ValueInitial Words0PC (PLC)AddressI/O CommentsRef0––––10Automaticn0––––11Manualn0––––12Stepn0––––13Resetn0––––––Line 1 Errorn20D00150Alarm data 1––21Line 2 Errorn20D00170Alarm data 2––22A-spot Screw Errorn20D00190Alarm data 3––23B-spot Screw Errorn20D00210Alarm data 4––24Low Pressuren20D00230Alarm data 5––25Area 1 Alarmn20D00250Alarm data 6––26Area 2 Alarmn20D00270Alarm data 7––27PC (PLC) Network Errorn20D00290Alarm data 8––20369Creating the Sample DataSection 9-3Setting bit memory tables(1) Click on [Bit Memory].(2) Make the bit memory table settings as shown below.Pressto set the following items.S FunctionS HistoryS Switch ScreenS String Table EntryS Image/Library CodeS ColourPressto set the following items.(Direct input on a bit memory table is also possible.)S PLC AddressS I/O CommentsStringTableEntryImage/LibraryCode*1ColourPCAddressI/OCommentsAlarm/SwitchScreen20FA20White0002000Alarm 11Alarm/SwitchScreen21FA21White0002001Alarm 22Alarm/SwitchScreen22FA22White0002002Alarm 33Alarm/SwitchScreen23FA22White0002003Alarm 44Alarm/SwitchScreen24FA23White0002004Alarm 55Alarm/SwitchScreen25FA24White0002005Alarm 66Alarm/SwitchScreen26FA24White0002006Alarm 77Alarm/SwitchScreen27FA25White0002007Alarm 8No.Function0SwitchScreenHistory*1: With NT31, NT31C, NT631, NT631C, set “Alarm” for function and unmark thecheck box for “Switch Screen”.370Creating the Sample Data9-3-5Section 9-3Creating the Menu ScreenCreate the Menu Screen.Display the data creation window for screen No.
1, which is displayed at the startup of the Support Tool, at the front.Setting the screen properties(1) Select [Screen] (menu bar) → [Properties].(2) Set the screen properties as shown below for screen No. 1. (Refer to 5-1-1“Setting the Screen Attributes”.)AttributesScreen No.1HistorynTitleMenu ScreenCommentMenu ScreenBuzzern, ShortLoad Local 1 (Keyboard)System KeypadColourGridBackgroundBlackGrid SizeCustomHorizontal Spacing: 5Vertical Spacing:5Display GridnSnap to GridnCreating the screen title ([Menu Screen])S Setting the characters(1) Select [Objects] (menu bar) → [Fixed Display] → [Text] (Refer to 6-2-7“Text”.)(2) Click the mouse with the mouse cursor set at the position where the screentitle is to be displayed (at the intended upper left corner of text).371Creating the Sample DataSection 9-3(3) Set the properties as shown below.DescriptionMenu ScreenPosition––Font TypeStandardScale2SmoothingnAttributeStandardColour2ForegroundWhiteBackgroundTransparent(4) Adjust the position of “Menu Screen” on the data creation screen by dragging it.S Surrounding the title with a frame(5) Select [Objects] (menu bar) → [Fixed Display] → [Rectangle].
(Refer to6-2-3 “Rectangle”.)(6) On the data creation screen, drag the “rectangle” so that it encloses the“Menu Screen” (character) string.(7) Use the properties as they are.(8) Adjust the size and the position of the frame (rectangle).Creating the [Monitor Screen] buttonS Setting the touch switch outline(1) Select [Objects] (menu bar) → [Touch Switch]. (Refer to 6-8 “TouchSwitches”.)(2) Create the outline of the [Monitor Screen] button by dragging the mouse onthe data creation screen.(3) Set the properties as shown below.372Creating the Sample DataSection 9-3GeneralPosition––Size––nLabelDescriptionMonitor Screen(Refer to the following) *1FramenShape3-DimensionShow ON StateColourSettingsLightFunction––FrameWhiteONWhiteOFFTransparentFunctionSwitch ScreenScreen No.2AddressPC (PLC) Address––I/O Comments––Lamp Attribute*1:LightPressto set the label.After completing the setting, go to the next step without clicking onbutton.S Setting the touch switch label(4) Pressin the general property of a touch switch and set the labelproperties as shown below.DescriptionMonitor ScreenPosition––Font TypeStandardScale2SmoothingnAttributeStandardColourClick on2ForegroundWhiteBackgroundTransparent, (return to touch switch property) then click onagain.S Adjusting the size and position of the touch switch(5) Adjust the size and position of the frame of [Monitor Screen] button.(6) Specify the [Monitor Screen] button.(7) Select [Centralize Label] from [Draw] menu.The label is centralized.373Creating the Sample DataSection 9-3Creating the [Set Screen] buttonS Copying and pasting the [Monitor Screen] button(1) Specify the [Monitor Screen] button.(2) Select [Edit] (menu bar) → [Copy].
(Refer to 6-1-5 “Copying, Cutting, Pasting and Deleting Elements”.)(3) Select [Edit] (menu bar) → [Paste]. (Refer to 6-1-5 “Copying, Cutting, Pasting, and Deleting Elements”.)(4) Drag the [Monitor Screen] button, displayed at the upper left area in the datacreation screen, to the position where you want to create the [Set Screen]button.S Modifying to the [Set Screen] button(5) Double click the moved button and modify the properties as shown below.Note that other properties must be left unchanged.AttributenLabelDescriptionSettings*1:Screen No.PressSet Screen*13to set the label.Creating the [Alarm Screen] buttonS Copying and pasting the [Monitor Screen] button(1) Specify the [Monitor Screen] button.(2) Select [Edit] (menu bar) → [Copy].(3) Select [Edit] (menu bar) → [Paste].(4) Drag the [Monitor Screen] button, displayed at the upper left area in the datacreation screen, to the position where you want to create the [Alarm Screen]button.S Modifying to the [Alarm Screen] button(5) Double click the moved button and modify the properties as shown below.Note that other properties must be left unchanged.GeneralnLabelDescriptionSettings*1:374PressScreen No.to set the label.Alarm Screen*14Creating the Sample Data9-3-6Section 9-3Creating the Monitor Screen (Child Screen 1)The monitor screen is an overlapping screen with screen Nos.