The character setting dialog box is displayed.(Presently, “Color” setting is notsupported. It will be invalid evenif it was specified.)Copying the reference graphicsTo reuse the existing graphic displayed in the reference graphic display area,specify the range to be copied and click onabove the reference graphic displayarea. After copying the graphic, click onPaste buttonabove the edit area.Copy buttonSpecifyingthe copy range352Mark EditorSection 8-3Quitting the mark editorTo quit the mark editor, click on theIf you click onmark editor.button of the mark editor., the created mark data is discarded before you quit the[OK] buttonDeleting mark dataTo delete the mark data, specify the mark data to be deleted in the mark data listdialog box and click on.Reset button353Mark Editor354Section 8-3SECTION 9Example ScreensThis section is intended to familiarize you with the operation of the Support Tool through actual operation.The operational procedures for creating example screens are explained step by step.Please follow the steps shown in this section and create example screens in order to understand the functions and the features ofthe Support Tool.Please do not forget to save the screen data frequently.
(Refer to 3-3-3 “Saving the Screen Data (Application) File”.)The sample screen data to be created in this section is supplied by the CD–ROM version Support Tool.Use this data to check the setting status etc.(This data is provided just as a sample screen data. It is not created for the purpose of actual operation on PT after downloading itto PT.)9-19-29-3Example Screen Configuration . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1-1 Screen Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-1-2 Screen Transfer among Example Screens . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operation Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Creating the Sample Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .9-3-1 Starting up the Support Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-2 [File] – [New] . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-3 Setting the PT Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-4 Setting Memory Tables . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .9-3-5 Creating the Menu Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-6 Creating the Monitor Screen (Child Screen 1) . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .9-3-7 Creating the Monitor Screen (Child Screen 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-8 Creating the Monitor Screen (Parent Screen) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-9 Creating the Set Screen .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-10 Creating the Alarm Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-11 Creating the Alarm List Library Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .9-3-12 Creating the Pop-up Display Numeric Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-3-13 Saving the Created Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .9-3-14 Downloading to the PT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .356356357363367367367367368371375381392393405411413417418355Example Screen Configuration9-1Section 9-1Example Screen ConfigurationThe configuration and screen transfer of the example screens you are going tocreate are described below.9-1-1Screen ConfigurationMenu Screen (Screen No. 1)PT power ONMonitorScreenbuttonAlarmScreenbuttonMenubuttonSetScreenbuttonMenubuttonSet Screen (Screen No. 3)Monitor Screen (Screen No.
2)SetbuttonMonitorbuttonAlarmbuttonAlarm Screen(Screen No. 4)356MonitorbuttonMenubuttonAlarmbuttonSetbuttonExample Screen ConfigurationSection 9-1Create the Monitor Screen as an overlapping screen comprising screen No. 10and screen No. 11.Parent screen (screen No. 2)9-1-2Child screen (screen No. 10)Child screen (screen No. 11)Screen Transfer among Example ScreensHow the displayed screen switches according to the button operation is shown below.Menu ScreenS [Monitor Screen] buttonSwitches the screen to the Monitor Screen (screen No. 2).S [Set Screen] buttonSwitches the screen to the Set Screen (screen No.
3).S [Alarm Screen] buttonSwitches the screen to the Alarm Screen (screen No. 4).357Example Screen ConfigurationSection 9-1Monitor ScreenS [Numeral Display 1]Displays the value of DM0000 in the PC (PLC).S [Numeral Display 2]Displays the value of 32-bit data, the sum of DM0001 and DM0002 in the PC(PLC).S [Trend graph]Displays the value of DM0003 and DM0004 in the PC (PLC) in the form of a trendgraph.Set the –100%, 0%, and 100% values as shown below.value for –100%value for 0value for 100%DM0003–8000800DM000406001200S [Lamp1] to [Lamp 5]Displays the ON/OFF state of L000000 to L000004 in the PC (PLC).When L000000 is ON (OFF), Lamp 1 goes ON (OFF).When L000001 is ON (OFF), Lamp 2 goes ON (OFF).When L000002 is ON (OFF), Lamp 3 goes ON (OFF).When L000003 is ON (OFF), Lamp 4 goes ON (OFF).When L000004 is ON (OFF), Lamp 5 goes ON (OFF).S [Image Lamp]Displays the ON/OFF state of L000005 in the PC (PLC).Display when L000005 is ON.Display when L000005 is OFF.358Example Screen ConfigurationSection 9-1S [Bar Graph 1]Displays the value of DM0005 in the PC (PLC) in the form of a bar graph.Set the –100%, 0%, and 100% values as shown below.DM0005value for –100%value for 0value for 100%–5000500S [Bar Graph 2]Displays the value of DM0006 in the PC (PLC) in the form of a bar graph.Set the –100%, 0%, and 100% values as shown below.DM0006value for –100%value for 0value for 100%–3000300S [Menu]This is a screen switching button.When you touch this button, the screen switches to the Menu Screen (screen No.1).S [Set]This is a screen switching button.When you touch this button, the screen switches to the Set Screen (screen No.3).S [Alarm]This is a screen switching button.When you touch this button, the screen switches to the Alarm Screen (screenNo.
4).Set ScreenS [Numeral Input 1]Used to set the data at two words, DM0010 and DM0011, in the PC (PLC).When you touch the numeral display area, numeric keys are displayed (pop-upwindow), allowing you to input the data.359Example Screen ConfigurationSection 9-1S [Numeral Input 2]Used to set the data at two words, DM0012 and DM0013, in the PC (PLC).When you touch the numeral display area, numeric keys are displayed (pop-upwindow), allowing you to input the data.S [Thumbwheel]Used to set the data at DM0014 in the PC (PLC).S [String Display], [Auto.]/[Man.]/[Step]/[Reset]When you touch any of the [Auto.], [Man.], [Step], and [Reset] buttons, the following (character) string is displayed in the [String Display] filed.[Auto.] button:Automatic[Man.] button:Manual[Step] button:Step[Reset] button:ResetS [Start]This is a momentary type button.When you touch this button, L000100 in the PC (PLC) goes ON.If L000200 in the PC (PLC) goes ON, the button lights.S [Stop]This is a momentary type button.When you touch this button, L000101 in the PC (PLC) goes ON.If L000201 in the PC (PLC) goes ON, the button lights.S [Menu]This is a screen switching button.When you touch this button, the screen switches to the Menu Screen (screen No.1).S [Monitor]This a screen switching button.When you touch this button, the screen switches to the Monitor Screen (screenNo.
2).S [Alarm]This is a screen switching button.When you touch this button, the screen switches to the Alarm Screen (screenNo. 4).360Example Screen ConfigurationSection 9-1Alarm ScreenS Alarm list and contentsAllocate 0002000 to 0002007 in the PC (PLC) as alarm bits.If any of the allocated bits goes ON, the corresponding alarm message is displayed.When you touch the alarm message, the corrective action and details of thealarm are displayed in the alarm content display area.BitsAlarm MessageAlarm Content Display0002000Line 1 ErrorSet line 1.0002001Line 2 ErrorSet line 2.0002002A-spot Screw ErrorCheck torque screw.0002003B-spot Screw ErrorCheck torque screw.0002004Low PressureCheck pipe and valve.0002005Area 1 AlarmDetection near entry. Confirm safetybefore restarting the line.0002006Area 2 AlarmDetection near entry.
Confirm safetybefore restarting the line.0002007PC (PLC) NetworkErrorCheck the PC (PLC) and the network.S [Menu]This is a screen switching button.When you touch this button, the screen switches to the Menu Screen (screen No.1).S [Monitor]This is a screen switching button.When you touch this button, the screen switches to the Monitor Screen (screenNo.
2).S [Set]This is a screen switching button.When you touch this button, the screen switches to the Set Screen (screen No.3).361Example Screen ConfigurationSection 9-1Required environmentThe required hardware environment for the creation of the example screens isshown below.S PT model:NT620C/625CS Image memory:512 KbytesS Memory table capacity:Numeral memory tableCharacter string memory table (String table)362512256Operation Flow9-2Section 9-2Operation FlowCreate the example screens by following the steps shown below.Start up the Support Tool↓[File] – [New]↓Set PT configuration↓Set memory tables↓Creating the Menu ScreenCreate new screen (screen No.
1)↓Set properties for screen No. 1↓Create screen title↓Create [Monitor Screen] button↓Create [Set Screen] button↓Create [Alarm Screen] button↓Creating Monitor ScreenCreate new screen (screen No. 10)↓Set properties for screen No. 10↓Create screen title↓Create numeral display field of [Numeral Display 1]↓Create numeral display field of [Numeral Display 2]↓(1)363Operation FlowSection 9-2(1)↓Create [Trend graph]↓Create new screen (screen No. 11)↓Set properties for screen No.