(It is possible to centralize multiple lamp/touch switch labels collectively.)Selecting method oflamp/touch switch labelSelect a lamp or atouch switch and enterthe Edit Object mode,then select the label.Besides the methods mentioned left, 6–1–3it is possible to select the label directly by clicking it while pressingthe Shift key and Ctrl key.Default table entry fornumeral/string inputand thumbwheel.Fixed to numeral/stringentry “0”.Default table entry is incrementedautomatically so that the numeral/string table entry does not overlapwith the ones already used for thenumeral/string input or thumbwheelon the same screen.6–4Options for ScreenImage printing (Inverseprinting, screen grid/dotted line frame printing) For monochromePTs, the screen is always inversed forprinting.
For colorPTs, the screen is always printed as it is.For Screen Image printing, optionsbelow are added.12–2–2 If you do not want toprint screen grid, youneed to uncheck the“Display Grid” settingof each screen’sproperty.528Appendix F Inverse Print Hide Screen Grid Show Dotted Line FrameAppendix F New Functions of Support Tool Ver.3.2ItemsNT Transfer UtilityVer.3.0NoneParts Collection (lamps/ Nonetouch switches)Appendix FVer.3.2PageSupplied with CD–ROM version(This is software which executesdownloading/uploading of thescreen data in mmi format at site).App, CSupplied with CD–ROM version(This is a parts collection of graphical lamps/touch switches combinedwith image/library).3–3–7529Error MessagesAppendix GAPPENDIX GError MessagesThe error message that may be displayed while using the Support Tool, and theaction to take in response to them, are shown below.The indications [W] and [E], given at the beginning of an error message, classifythe level of errors as indicated below.[W]:Minor error (permits transmission and execution of screen data)[E]:Major error (disables transmission of screen data)Error MessageCorrective ActionSign% display or other element(s) cannotoverlap with the Trend Graph.A “% display” or other element is overlapping the trend graph.
Move the elementoutside the trend graph frame.AApplication version mismatched; Communication aborted.Syetem program version installed in a PTmaybe a lower one. For details of the combination of system program version that canbe transmitted and the PT model setting atthe Suppourt Tool, refer to 11–1–2.For details of updating the system program,refer to Appendix B.CCannot have more than XXX childscreens.When creating a new screen, insert a number of child screens that does not exceedthe maximum limit.Constant Value is out of limit. Maximumvalue restored.Correct the screen data or the program inthe host so that a constant of up to 8 digitsset for the copy setting touch switch willsuffice.Continuous screen does not allow childscreen to have Thumbwheel/Numeral/String Input elements.Delete thumbwheel switches, numeral inputelements, and/or (character) string inputelements.Control/Notify/Window Control area cannot overlap each other.Make sure that the PT status control area,the PT status notify area and the windowcontrol area are not overlapping each other.Cursor Move Touch Switch does not haveany association link.Select the cursor moving touch switch onthe screen, choose [Draw] – [Associate],then specify the element with which the selected touch switch is to be associated.DDue to length limitation, Input Key – String With NT620S, NT620C and NT625C, ifTouch Switch is only displaying part of the “(character) string input” is selected as thelabel message.touch switch function, up to 80 characterscan be set for an input (character) string.With NT31, NT31C, NT631 and NT631C,however, although up to 80 characters canbe set for a label, the limit is 40 charactersfor an input (character) string (a (character)string which is input using a touch switch).530Error MessagesAppendix GError MessageCorrective ActionF[Fixed Display Mark] – smoothing not sup- The mark is automatically displayed withoutported.
It is ignored.smoothing processing.IImage Table entry has been converted.If the converted image code differs from thecode of the image data that is to be displayed, correct the code.Incompatible PT hardware connected;communication aborted.The PT model between the screen dataand the target PT is mismatching on downloading/puloading.
Check the contents ofPT Configuration.Input key-window/keyboard screen numCreate the window/keyboard screen for aber is not within the valid range. Minimum screen number in the range 1900 to 1979value restored.and convert the window/keyboard screennumber set for the touch switch accordingly.LLibrary Table Entry has been converted.If the converted library code differs from thecode of the library data that is to be displayed, correct the code.MMemory access mismatched; communica- Target PLC vendor type or PT type is mistion aborted.matching between the Support Tool and PThardware.
Confirm the Support Tool andPT side PLC vendor and PT type is mismatching.Memory utilization has exceeded the XXXbytes limit by YYY bytes.Delete several elements.Memory utilization has exceeded the XXXbytes limit by YYY bytes.Delete several elements and screens.More than one Numeral Input/ThumbSet different numeral memory table numwheel are referring to Numeral Table entry bers at the numeral input and thumbwheel0.switch properties.NNotify Area not specified.Control Area not specified.Number of [Object name] has exceededthe XXX limit by YYY.Set the PC (PLC) address for the PT statuscontrol area/PT status notify area after selecting [Tools] – [PT Configuration].Delete several elements.[Numeral Input] – Total number of integer Create the numeral input field again.
Corand decimal exceeds limit. It is discarded. rect the screen data and the program in thehost so that numeric values such as maximum/minimum check values and an inputvalue of up to 8 digits will suffice.O[Object Name] – % value is out of limit.Default values restored for 100%, 0%,and –100%.Correct the screen data or the program atthe host so that a value of up to 8 digits willbe sufficient for the 100% value, 0% valueand –100% value in the bar graph.[Object Name] has exceeded the maximum number of characters.Set the (character) string within the limit.[Object name] refers to invalid numeraltable entry. The referenced table entry isreset to entry 0.Correct the table number to a number within the valid range. If the table number isspecified in a program, correct the programalso.531Error MessagesAppendix GError MessageOCorrective Action[Object Name] – Invalid PLC address.
Itis reset to default.Reset the word number to a number of upto 4 digits. If this PC (PLC) address is referred to from the program, it is necessaryto correct the program accordingly.[Object Name] – inverse attribute not supported. Foreground and Backgroundcolours interchanged.Since foreground color and background color are automatically interchanged, no special correction is required (display attributeis set to default (standard).).Overlapping screen has more than 1 childscreen containing Thumbwheel/Numeral/String Input elements.An overlapping screen does not allow thesetting of multiple input functions.
Correctthe child screen.PPlease make sure this parent screen have Select the parent screen, then right clickat least 2 children.the mouse and select [Modify]. Insert atleast 2 child screens for the parent screen.SSampling cycle less than the minimumvalue. Minimum value is restored.Since there are no problems in actual operation, correction is not necessary.Sampling cycle not multiple of 5.
Valuerounded off to nearest multiple of 5.Since there are no problems in actual operation, correction is not necessary.Screen is empty, downloading may not bepossible.Create the data in the empty screen or delete the empty screen.Some objects exceed library size in code Reduce the size of elements exceeding theFA20.
The objects will not be downloaded library size using the library editor, or set ato PT hardware.larger library size.String Table: Table Entry XXX has invalidcomponent code. It has been convertedfrom XXXX to YYYY.T532Delete the code from the (character) stringand make corrections so that an equivalentdisplay can be obtained by displaying andgrouping the (character) string and the fixeddisplay image/library data.The associated touch switches of theCorrect the position of the control touchalarm has been discarded and component switches as needed. If a control touchtouch switches have been created.switch is not necessary, cancel the checkfor the control touch switch in the alarm list/history properties.