Диссертация (1154885), страница 17
Текст из файла (страница 17)
– Vol.30 (8). – P.19.66.Akhtar S., Malek S., Hariharan K. Hallux varus following scarf osteotomy // Foot(Edinb). – 2016. – Vol.29. – P.1-5.67.Aldana P.R., Wieder K., Postlethwait R.A. et al. Ultrasound-aided fixation ofbiodegradable implants in pediatric craniofacial surgery // Pediatr.
Neurosurg. – 2011. –Vol.47 (5). – P.349–353.68.Al-Sukhun J., Penttil H., Ashammakhi N. Orbital stress analysis, Part IV: Use ofa "stiffness-graded" biodegradable implants to repair orbital blow-out fracture // J.Craniofac. Surg. – 2012. – Vol.23 (1). – P.126–130.69.Ames C.P., Acosta F.L., Chamberlain R.H. et al.
Biomechanical analy¬sis of anewly designed bioabsorbable anterior cervical plate. Invited submission from the jointsection meeting on disorders of the spine and peripheral nerves // J. Neurosurg Spine. –2005. –Vol.3 (6). – P.465–470.10170.Andriano K.P., Pohjonen T., Tormal P. Processing and characterization ofabsorbable polylactide polymers for use in surgical implants // J. Appl.
Biomater. –1994. – Vol.5 (2). – P.133–140.71.Arora R., Milz S., Sprecher C. et al. Behaviour of ChronOS™ Inject inmetaphyseal bone defects of distal radius fractures: tissue reaction after 6–15 months //Injury. – 2012. – Vol.43 (10). – P.1683–1688.72.Austin D.W., Leventen E.O.
A new osteotomy for hallux valgus: a horizontallydirected "V" displacement osteotomy of the metatarsal head for hallux valgus andprimus varus // Clin. Orthop. Relat. Res. – 1981. – Vol. 157. – P.25–30.73.Barouk L.S. Forefoot reconstruction. – Paris: Springer Verlag, 2002.
– P. 359–364.74.Bayat M., Garajei A., Ghorbani K., Motamedi M.H. Treatment of mandibularangle fractures using a single bioresorbable miniplate // J. Oral. Maxillofac. Surg. –2010. – Vol. 68 (7). – P.1573–1537.75.Bennett G.L., Sabetta J.A. Evaluation of an Innovative Fixation System forChevron Bunionectomy // Foot Ankle Int. – 2016. – Vol.37 (2). – P.205-209.76.Bhatt K., Roychoudhury A., Bhutia O.
et al. Equivalence randomized controlledtrial of bioresorbable versus titanium miniplates in treatment of mandibular fracture: apilot study // J. Oral. Maxillofac. Surg. – 2010. – Vol.68 (8). – P.1842–1848.77.Biber R., Pauser J., Geilein M., Bail H.J. Magnesium-Based Absorbable MetalScrews for Intra-Articular Fracture Fixation // Case Rep Orthop. - 2016;2016:9673174.78.Biz C., Fosser M., Dalmau-Pastor M. et al. Functional and radiographic outcomesof hallux valgus correction by mini-invasive surgery with Reverdin-Isham and Akinpercutaneous osteotomies: a longitudinal prospective study with a 48-month follow-up// J.
Orthop. Surg. Res. – 2016. – Vol.11(1). – P.157.79.Blakey G.H., Rossouw E., Turvey T.A. et al. Are bioresorbable polylactatedevices comparable to titanium devices for stabilizing Le Fort I advancement? // Int. J.Oral. Maxillofac. Surg. – 2014. – Vol.43 (4). – P.437–444.10280.Boden R.A., Burgess E., Enion D. et al. Use of bioabsorbable knotless sutureanchors and associated accelerated shoulder arthropathy: report of 3 cases // Am. J.Sports Med. – 2009.
– Vol.37. – P.1429–1433.81.Bos R.R., Rozema F.R., Boering G. et al. Bioabsorbable plates and screws forinternal fixation of mandibular fractures. A study in six dogs // Int. J. Oral. MaxillofaSurg. – 1989. – Vol. 18(6). – P. 365–369.82.Bos R.R., Rozema F.R., Boering G. et al. Degradation of and tissue reaction tobiodegradable poly(L-lactide) for use as internal fixation of fractures: a study in rats //Biomaterials.
– 1991. – Vol. 12. – P.32–36.83.Bostman O., Paivarinta U., Partio E. et al. Absorbable polyglycolic screws ininternal fixation of femoral osteotomies in rabbits // Acta Orthop. Scand. – 1991. – Vol.62. – P. 587–591.84.Bostman O., Makela E.A., Tormala P., Rokkanen P. Transphyseal fracturefixation using biodegradable pins // J.
Bone Joint Surg (Br). – 1989. – Vol. 71. – P.701–707.85.Bostman O.M., Laitinen O.M., Tynninen O. et al. Tissue restoration afterresorption of polyglycolide and poly-llaevo¬lactic acid screws // J. Bone Joint. Surg.(Br). – 2005. – Vol. 87. – P.1575–1580.86.Brown K., Swank A., Quesada P.
et al. Prehabilitation versus usual care beforetotal knee arthroplasty: A case report comparing outcomes within the same individual //Physiother. Theory Pract. – 2010.– Vol.26 (6). – P.399–407.87.Brunetti V.A., Trpal M.J., Jules K.T. Fixation of Austin osteotomy withbiosorbable pins // J. Foot Surg. – 1991. – Vol. 30. – P. 56–65.88.Buciuto R. Prospective randomized study of chevron osteotomy versus Mitchell'sosteotomy in hallux valgus // Foot Ankle Int.
– 2014. – Vol.35 (12). – P.1268–1276.89.Buckley R.E., Seadon S. Infections in calcaneal fracture patients treated withopen reduction and internal fixation and bioresorbable calcium phosphate paste: a caseseries // Foot Ankle Int. – 2012.
– Vol.33 (11). – P.997–1000.10390.Buijs G.J., Van Bakelen N.B., Jansma J. et al. A randomized clinical trial ofbiodegradable and titanium fixation systems in maxillofacial surgery // J. Dent. Res. –2012. –Vol.91 (3). – P.299–304.91.Burkhart S.S. The evolution of clinical applications of biodegradable implants inarthroscopic surgery // Biomaterials. – 2000. – Vol.21. – P.2631–2634.92.Caminear D.S., Pavlovich R., Pietrzak W.S. Fixation of the chevron osteotomywith an absorbable copolymer pin for treatment of hallux valgus deformity // J. FootAnkle Surg.
– 2005. – Vol. 44. – P.203–210.93.Chen J.Y., Lee M.J., Rikhraj K. et al. Effect of Obesity on Outcome of HalluxValgus Surgery // Foot Ankle Int. – 2015. – Apr 16. [Epub ahead of print]94.Cho S.Y., Chae S.W., Choi K.W. et al. Biocompatibility and strength retention ofbiodegradable Mg-Ca-Zn alloy bone implants // J. Biomed. Mater.
Res B ApplBiomater. – 2013. –Vol.101 (2). – P.201–212.95.Choi H.J., Kim W., Youn S., Lee J.H. Management of delayed infection afterinsertion of bioresorbable plates at the infraorbital rim // Craniofac. Surg. – 2012. –Vol.23 (2). – P.524–525.96.Chopra S., Moerenhout K., Crevoisier X. Characterization of gait in femalepatients with moderate to severe hallux valgus deformity // Clin. Biomech. (Bristol,Avon).
– 2015. – Vol.30 (6). – P.629–635.97.Coe J.D., Vaccaro A.R. Instrumented transforaminal lumbar interbody fusionwith bioresorbable polymer implants and iliac crest autograft // Spine. – 2005. – Vol.30(17 ). – P.76–83.98.Coughlin M.J., Jones C.P. Hallux valgus: demographics, etiology, andradiographic assessment // Foot Ankle Int. – 2007.
– Vol. 28. – P.759–777.99.Degala S., Shetty S., Ramya S. Fixation of zygomatic and mandibular fractureswith biodegradable plates // Ann. Maxillofac. Surg. – 2013. – Vol.3 (1). – P.25–30.100. Dhawan R.K., Mangham D.C., Graham N.M. Periprosthetic femoral fracture dueto biodegradable cement restrictor // J. Arthroplasty. – 2012. – Vol.27 (8). – P.1581.104101. Di Giorgio L., Sodano L., Touloupakis G. et al.
Reverdin-Isham osteotomyversus Endolog system for correction of moderate hallux valgus deformity: aRandomized Controlled Trial // Clin Ter. – 2016. – Vol.167 (6). – P.150-154.102. Doty J.F., Alvarez R.G., Ervin T.B. et al. Biomechanical Evaluation of CustomFoot Orthoses for Hallux Valgus Deformity // J. Foot Ankle Surg. – 2015. – Jun 6.[Epub ahead of print]103. Drampalos E., Vun S.H., Fayyaz I. Intramedullary and intra-osseous arthrodesisof the hallux metatarsophalangeal joint // J.
Orthop. Surg. (Hong Kong). – 2016. –Vol.24 (3). – P.358-361.104. Duke H.F., Kaplan E.M. A modification of the Austin bunionectomy forshortening and plantarflexion // J. Am. Podiatry. – 1984. – Vol. 74. – P. 209–211105. Dumas J.E., Zienkiewicz K., Tanner S.A. et al.
Synthesis and characterization ofan injectable allograft bone/polymer composite bone void filler with tunable mechanicalproperties // Tissue Eng. Part A. – 2010. – Vol.16 (8). – P.2505–2518.106. Edmonds E.W. Use of an absorbable plate in the management of a claviclefracture in an adolescent // Am. J. Orthop.
(Belle Mead NJ). – 2012. – Vol.41 (1). –P.29–32.107. Elhalawany S.K., Tarakji B., Azzeghaiby S. et al. Clinical and radiographicevaluation of biodegradable bone plates in the treatment of mandibular body fractures //Niger Med. J. – 2015. – Vol.56 (1). – P.48–53.108. Erschbamer M., Zdravkovic V., Erhardt J. et al. Osteolytic changes aroundbiodegradable cement restrictors in hip surgery // Acta Orthop. – 2016.
– Vol.87 (3). –P.239-244.109. Esemenli T. Chevron osteotomy: a clinical and radiographic analysis // FootAnkle Int. – 1998. – Vol. 19 (1). – P. 60–61.110. Fakoor M., Sarafan N., Mohammadhoseini P. et al. Comparison of ClinicalOutcomes of Scarf and Chevron Osteotomies and the McBride Procedure in theTreatment of Hallux Valgus Deformity // Arch. Bone Jt. Surg. – 2014.
– Vol.2 (1). –P.31–36.105111. Farraro K.F., Kim K.E., Woo S.L. et al. Revolutionizing orthopaedicbiomaterials: The potential of biodegradable and bioresorbable magnesium-basedmaterials for functional tissue engineering // J. Biomech. – 2014. – Vol.47 (9). –P.1979–1986.112. Feinstein M.H., Brown H.N. Hallux adductus as a surgical complication // J. FootSurg. – 1980. – Vol.