9.2 VA at 264 VACApprox. 7.2 VA at 26.4 VACApprox. 3.7 W at 12 VDCMounting methodFlush mountingExternal connectionsScrew terminalsTerminal screw tightening torque0.5 N·m max.Display (See note 2.)7-segment, negative transmissive LCDPV11.5-mm-high characters, red or green(programmable)SV6-mm-high characters, greenPreset counter/tachometer100 to 240 VAC (50/60 Hz),24 VAC (50/60 Hz)/12 to 24 VDC,12 to 24 VDC9-mm-high characters, red or green (programmable)Digits4 digits (−999 to 9,999)SV range: 0 to 9,999Input signalsCP1, CP2, reset 1, and reset 2Input methodNo-voltage input/voltage input (switchable)No-voltage inputON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω)ON residual voltage: 3 V max.OFF impedance: 100 kΩ min.Voltage inputHigh (logic) level: 4.5 to 30 VDCLow (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)CounterTachometer100 to 240 VAC (50/60 Hz),24 VAC (50/60 Hz)/12 to 24 VDC6 digits (−99,999 to 999,999 or 0 to 999,999 when using as Tachometer)SV range: −99,999 to 999,999 (See note 3.) or 0 to 999,999Max.
counting speed30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2Input modeIncrement, decrement, command, individual, and quadratureReset inputMinimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputsReset systemExternal, manual, and automatic reset (internal according to C, R, P, and Q mode operation)Output modesN, F, C, R, K-1, P, Q, AOne-shot output time0.01 to 99.99 sPulse measurementmethod---Periodic measurement (Sampling period: 200 ms)Max. counting speed---30 Hz or 10 kHz (selectable)Measuring ranges---30 Hz: 0.01 to 30.00 Hz10 kHz: 0.01 Hz to 10 kHzMeasuring accuracy---±0.1% FS ±1 digit max. (at 23 ±5°C)Output modes---HI-LO, AREA, HI-HI, LO-LOAuto-zero time---0.1 to 99.9 sStartup time---0.0 to 99.9 sAverage processing---OFF/2/4/8 timesN, F, C, R, K-1, P, Q, A, K-2, D, L, HOutput typeH7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1)H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistorsControl outputContact output:3 A at 250 VAC/30 VDC, resistive load (cosφ=1)Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)Transistor output:NPN open collector, 100 mA at 30 VDCResidual voltage: 1.5 VDC max.
(approx. 1 V)Leakage current: 0.1 mA max.H7CX-AU/-AUD1: SPDT and 1 transistorH7CX-AUSD1: 2 transistors(Output allocation possible)NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VACExternal power supply12 VDC (±10%), 100 mA (except for H7CX-A@D models)Refer to Safety Precautions (page 60) for details.Key protectionYesPrescaling functionYes (0.001 to 9.999)Decimal point adjustmentYes (rightmost 3 digits)Sensor waiting time250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)Memory backupEEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.Ambient temperatureOperating:Storage:Ambient humidity25% to 85%Case colorBlack (N1.5), light gray (Munsell 5Y7/1, produced upon request)AttachmentsWaterproof packing, flush mounting adapt- Waterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settingserYes (0.001 to 99.999)−10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation)−25 to 65°C (with no icing or condensation)Note: 1.
Permissible ripple: 20% (p-p) max.2. The display is lit only when the power is ON.3. Only when the following modes are selected.- Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H- Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operationMultifunction Preset CounterH7CX-A5■ CharacteristicsitemH7CXInsulation resistance100 MΩ min.
(at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contactsDielectric strength2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts2,000 VAC (for 100 to 240 VAC), 50/60 Hz for 1 min between power supply and input circuit (1,000 VAC for 24 VAC/12 to 24 VDC)1,000 VAC (for H7CX-@SD/-@SD1), 50/60 Hz for 1 min between control output, power supply, and input circuit(2,000 VAC for models other than H7CX-@SD/-@SD1)1,000 VAC, 50/60 Hz for 1 min between non-continuous contactsImpulse withstandvoltage3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDC4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC,1.5 kV for 24 VAC/12 to 24 VDC and 12 to 24 VDCNoise immunity±1.5 kV (between power terminals) for 100 to 240 VAC and 24 VAC/12 to 24 VDC, ±480 V for 12 to 24 VDC±600 V (between input terminals)Square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)Static immunityDestruction: 15 kVMalfunction: 8 kVVibration resistanceDestruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle)Malfunction: 10 to 55 Hz with 0.35-mm single amplitude, four cycles each in three directions (8 minutes per cycle)Shock resistanceDestruction: 294 m/s2 each in three directionsMalfunction: 98 m/s2 each in three directionsLife expectancyMechanical: 10,000,000 operations min.Electrical: 100,000 operations min.
(3 A at 250 VAC, resistive load)See Life-test Curve on page 7.Approved safetystandards(See notes 1 and 2.)UL508/Listing, UL 50 Type 4X for indoor use (enclosure rating)CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II)Conforms to VDE0106/P100 (finger protection).EMC(EMI)Emission Enclosure:Emission AC mains:(EMS)Immunity ESD:Degree of protectionPanel surface: IP66, NEMA 4 (indoors), and UL Type 4X (indoors) (See note 2.)WeightApprox.
140 gEN61326EN55011 Group 1 class AEN55011 Group 1 class AEN61326EN61000-4-2:4 kV contact discharge (level 2);8 kV air discharge (level 3)Immunity RF-interference:EN61000-4-3:10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3);10 V/m (Pulse-modulated, 900 MHz ±5 MHz) (level 3)Immunity Conducted Disturbance: EN61000-4-6:10 V (0.15 to 80 MHz) (level 3)Immunity Burst:EN61000-4-4:2 kV power-line (level 3);1 kV I/O signal-line (level 4)Immunity Surge:EN61000-4-5:1 kV line to lines (power and output lines) (level 2);2 kV line to ground (power and output lines) (level 3)Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage)Note: 1.
To meet UL listing requirements with the H7CX-A11@ models, an OMRON P2CF-11-@ or P3GA-11 Socket must be mounted on theH7CX. Otherwise, H7CX-A11@ models are considered to meet UL508 recognition requirements.2. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X waterproofing between the H7CX and installation panel.6Multifunction Preset Counter H7CX-A■ Life-test Curve (Reference Values)Resistive LoadInductive Load1,000No.
of operations (×103)No. of operations (×103)1,00070050030030 VDC (cosφ=1)250 VAC (cosφ=1)70050030030 VDC (L/R=7 ms)1001007070250 VAC cosφ=0.450500123041234Load current (A)Load current (A)Reference: A current of 0.15 A max. can be switched at 125 VDC (cosφ=1) and current of 0.1 A max. can be switched if L/R=7 ms. In both cases,a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P).■ Inrush Current (Reference Values)ModelH7CX-A11/-AWVoltage100 to 240 VACApplied voltage Inrush current (peak value)Time5.8 A0.7 msH7CX-A11D1/-AWD1 24 VAC/12 to 24 VDC 26.4 VAC10.4 A1.2 msH7CX-AD6.0 A1.2 ms12 to 24 VDC264 VAC26.4 VDCMultifunction Preset CounterH7CX-A7Connections■ Block Diagram(Basicinsulation)Output circuit(Basicinsulation)Power supplycircuit(See note.)Display circuitInternal controlcircuitInput circuitKey switchcircuitNote: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation.■ I/O FunctionsUsing as a CounterInputsOutputsCP1, CP2• In general (except for dual counter mode)Reads counting signalsIncrement, decrement, command, individual, and quadrature inputs accepted.• When used as a dual counterReads CP1 count signals with CP1 input and CP2 count signals with CP2 input.Increment signals can be input.Reset or Reset 1• In general (except for dual counter mode)Resets present value and outputs (OUT2 when using the batch counter).