The dialog box for setting a label is displayed. Set the property for the label to be displayed.For the procedure for setting the properties, refer to 6-2-7 “Text”. For NT31,NT31C, NT631, and NT631C, it is possible to set different colors for lamp ON andlamp OFF by setting [Colour – OFF] and [Colour – ON] instead of setting label color. However, background color is fixed to “transparent” for NT31, NT31C, NT631and NT631C.button in the property dialog can copy the I/O comment set to thelamp bit as a label.S To edit the position of a label, use the element edit function.
(For details, refer toP122)(1) Click on the label while pressing the Shift key and Ctrl key.(2) Drag the label to change the display position.(1)(2)211LampsSection 6-5Reference: S With a standard lamp, only the lamp color and the label color change. To changethe contents of a label, create image/library lamps and display different image/library data according to the status of the lamp.Example:ONOFFImage/library lampS With NT31, NT31C, NT631, and NT631C, image data cannot be inserted into alabel.6-5-2Image/library LampsDifferent image/library data are displayed according to the status of a PC (PLC) bit.Bit statusPC (PLC)Display whenthe bit is OFFDisplay whenthe bit is ON(1) The image data or the library data is switched to be displayed according to thestatus of the allocated PC (PLC) bit.Operation procedureSelection using the menu bar:Selection using the drawing toolbar:TerminologyImage/library data212[Objects] → [Lamp] → [Image]LampsSection 6-5Property setting[General]OFF StateCode:Specify whether or not image/library data is displayed in thelamp OFF state and the code of the image/library data to bedisplayed.ON StateCode:Specify whether or not image/library data is displayed in thelamp ON state and the code of the image/library data to bedisplayed.::Specify the image data to be displayed when the lamp is ON/OFF.Specify the library data to be displayed when the lamp is ON/OFF.Colour (Only for NT31C and NT631C.
Setting is not possible for other color typesof PT.)Foreground:Set the display color of an image element.(Specification of color is valid only when the color mode is “2colors”. Setting is not possible for a monochrome type PT.)Background:Set the display color of the background in the image elementdisplay area.(Specification of color is valid only when the color mode is “2colors”. Setting is not possible for a monochrome type PT.)[Light Functions]AddressPC (PLC) Bit Address: Specify the bit at the PC (PLC) which drives an image/library lamp ON/OFF.I/O Comment::Specify the comment of the PC (PLC) bit which drivesan image/library lamp ON/OFF.Displays the dialog box used to specify the bit number.Displays an I/O comment table.Reference: To check lamp ON status on the editing screen, select [Simulate ON/OFF] from[View] menu.
For details, refer to 5–1–3.213LampsSection 6-5GuidanceS For image/library lamp element, the image/library data which is displayed whenthe PC (PLC) bit is ON and the image/library data which is displayed when thePC (PLC) bit is OFF are specified independently.To display the image data or the library data only when the PC (PLC) bit is ON orOFF, cancel the check mark in the check box of the bit status for which the image/library data is not to be displayed.S To select the image/library data to be displayed, click onand select the desired image/library data from the list./Click on the line of the desired data to display the line in reverse video and click on.Clicking onenables the direct display of the specified code.S If the data is not registered to the specified code, the mark shown below is displayed on the screen.S For the procedure for creating the image data, refer to 8-1 “Image Editor”.S For the procedure for creating the library data, refer to 8-2 “Library Editor”.214Numeral Display6-6Section 6-6Numeral DisplayThe contents of a numeral memory table are displayed.Numeral displays can be used with all models.PTNumeralmemory tableScreenDisplay field5050ReadNo.1No.2No.3No.4No.5(1) The contents of the specified numeral memory table are displayed.Operation procedure[Objects] → [Numeral Display]Selection using the menu bar:Selection using the drawing toolbar:TerminologyForegroundBackgroundSign digitIntegerDecimalDisplay digits of maximum limitProperty setting[General]Position:Indicates the display position of the numeral display field.(The reference point is at the upper left corner of the display field.)Font Type:Specify the font of the numeric value to be displayed.Standard, Half Height, Double Width(Only Standard can be set for NT11S.)Scale:Specify the scale of the numeric value to be displayed.1 1 (Equal), 1 2 (High), 2 1 (Wide), 2 2, 3 3, 4 4, 8(Only 1 1 (Equal) and 2 1 (Wide) can be set for NT11S.)Smoothing:8Specify whether or not smoothing processing is executed fornumeric values to be displayed.(Setting is not possible for NT11S, NT20S and NT600S.)215Numeral DisplaySection 6-6Attribute:Specify the display attribute (attributes displayed depend on the PTmodel.)Standard, Inverse, Flash, Inverse FlashColourForeground:Specify the numeral color.(Can only be set for PTs with color display.)White, black, blue, red, magenta, green, cyan, yellowBackground:Specify the color of the background in the numeral display area.(Can only be set for PTs with color display.)White, black, blue, red, magenta, green, cyan, yellow[Settings]Reference:Indirect Reference:If a numeral in the specified memory table is treated as the reference tablenumber for indirect reference, specify this item.
(Setting is not possible forNT11S.)Table Entry:Specify the address of the numeral memory table to be referred to. If [IndirectReference] is not selected, the contents of this numeral memory table are displayed, and if [Indirect Reference] is selected, the contents of this numeralmemory table are treated as the reference table number and the contents ofthe reference memory table are displayed.Display Type (Only Decimal can be set for NT11S.)Decimal:Specify this item to display the input numeric value in decimal.Hexadecimal:Specify this item to display the input numeric value inhexadecimal.FormatInteger:Specify the number of digits of the integer part of the input data.Decimal:Specify the number of digits of the decimal fraction part of theinput data.Zero Suppression: Specify whether or not leading zeros are suppressed todisplay the input data.Display Sign::216Specify if a sign is displayed for a negative value.Displays the list of numeral memory tables.Numeral DisplaySection 6-6GuidanceS With a numeral display element, the memory table designation method can beselected as direct designation or indirect designation.Example: Specifying numeral memory table address “2”.Direct designationIndirect designationNumeralmemory tableNumeralmemory table152Display152334455The contents of the specifiedmemory table are displayed.Display5123123The contents of the specifiedmemory table are treated as thetable address reference value andthe contents of the referencedmemory table are displayed.Indirect designation is possible only in the following cases.
Do not apply for othercases.S When C200H I/F unit is used.S When NT30, NT30C, NT31, NT31C, NT620S, NT620C, NT625C, NT631,or NT631C is used.S When an NT20S or NT600S which uses the direct connection ver. 5. isused.With conventional models, up to 50 indirect designation settings can be made perscreen, including both numeral display and character string display.S For numeral display elements, it is possible to select whether numeric values aredisplayed in decimal (signed/unsigned) or hexadecimal.Numeralmemory table23456Display in decimal23456Display in hexadecimal5BA0Reference: S With NT31, NT31C, NT631, and NT631C, numerals are always stored as signedbinary data. When allocating numeral memory tables to PC (PLC) words, it ispossible to select whether the data is recognized in BCD or recognized in hexadecimal using the [Storage Type] property.217Numeral DisplaySection 6-6According to the combination of the storage type and display method, numericvalues are stored and displayed in the manner shown below.DisplayPC (PLC) channel(2-word allocation)Numeralmemory tableRecognition in BCD3456Display in decimal2345600005BA00002Display in hexadecimal5BA0Recognition in hexadecimal5BA00000S With NT30, NT30C, NT620S, NT620C, and NT625C, the only difference in decimal/hexadecimal display of a numeric value is whether or not “F” at the most significant digit is treated as a sign or a numeral.
With NT31, NT31C, NT631, andNT631C, however, the stored numeric value is converted for display accordingto the decimal/hexadecimal designation.S For [Decimal], the number of digits entered in decimal fraction part is specified.Since integers are stored in numeral memory tables, a decimal point is appended according to this setting when a numeral is displayed.Numeralmemory tableIf setting for [Decimal] is “2”.123412.34S If [Display Sign] is selected, a blank (“ ”) is displayed for a positive value and “–” isdisplayed for a negative value.If a negative value is displayed with [Display Sign] deselected, it is displayed asan absolute value.S For [Format] (number of numeral digits; integer part + decimal fraction part), seta sufficient value according to the contents of the numeral memory tables.The allowable display range for numeric values is shown below.Display MethodHexadecimalDecimal (signed)Decimal (unsigned)Conventional ModelsNew Models00000000 to FFFFFFFFH00000000 to 7FFFFFFFH–9999999 to 9999999–2147483648 to 21474836470 to 999999990 to 2147483647*1Conventional models: NT11S, NT20S, NT600S, NT30, NT30C, NT620S,NT620C, NT625CNew models:NT31, NT31C, NT631, NT631C*1: Since a negative value is also displayed as a positive value when [DisplaySign] is deselected, “−2147483648” is displayed as “2147483648”, eventhough the maximum value that can be stored in the numeral memory tableis “2147483648”.218(Character) String Display6-7Section 6-7(Character) String DisplayThe contents of a character string memory table are displayed.(Character) string displays can be used with all models.PTCharacter string memorytable (String table)ScreenDisplay fieldTOOL(1) The (character) string stored in the specified character stringmemory table (string table) is displayed.No.1No.2No.3TOOL No.4ReadNo.5Operation procedure[Objects] → [String Display]Selection using the menu bar:Selection using the drawing toolbar:TerminologyForegroundBackgroundProperty setting[General]Position:Indicates the display position of the (character) string display field.(The reference point is at the upper left corner of the display field.)Font Type:Specify the font of characters to be displayed.Standard, Half Height(Only Standard can be set for NT11S.)Scale:Specify the scale of characters to be displayed.1 1 (Equal), 1 2 (High), 2 1 (Wide), 2 2, 38 8 (Not possible for NT20S)3, 44Smoothing: Specify whether or not smoothing processing is executed forcharacters to be displayed.