(Setting is not possible for NT11S,NT20S and NT600S.)Attribute:Specify the display attribute (attributes displayed depend on the PTmodel.)Standard, Inverse, Flash, Inverse Flash219(Character) String DisplaySection 6-7ColourForeground: Specify the character color.(Can only be set for PTs with color display.)White, black, blue, red, magenta, green, cyan, yellowBackground: Specify the color of the background in the (character) stringdisplay area. (Can only be set for PTs with color display.)Transparent, white, black, blue, red, magenta, green, cyan,yellow[Settings]ReferenceIndirect Reference:If the numeric value in the specified memory table istreated as the reference table number and used for indirect table reference, specify this item. (Setting is notpossible for NT11S.)Table Entry:Specify the entry of the character string memory table(string table) to be referred to.
If [Indirect Reference] isnot selected, the contents of this character stringmemory table (string table) are displayed. If [IndirectReference] is selected, the contents of this numeralmemory table are treated as the reference table numberand the contents of the referenced character stringmemory table (string table) are displayed.Length: Specify the number of characters to be displayed.:Displays the list of numeral memory tables or character string memorytables (String Table). In indirect designation, the list of numeral memorytables is displayed and in direct designation, the list of character stringmemory tables (String Table) is displayed.GuidanceS With a (character) string display element, the memory table designation methodcan be selected as direct designation or indirect designation.ExampleSpecifying memory table address “2”Direct designationIndirect designationCharacter stringmemory table(String table)Character stringmemory table(String table)1Display11Display2TOOL22TOOL333444555TOOLThe contents of the specifiedmemory table are displayed.220Numeralmemory tableTOOLThe contents of the specified numeralmemory table are treated as the tableaddress reference value and thecontents of the referenced memorytable are displayed.(Character) String DisplaySection 6-7Indirect designation is possible only in the following cases.
Do not apply for othercases.S When C200H I/F unit is used.S When NT30, NT30C, NT31, NT31C, NT620S, NT620C, NT625C, NT631, orNT631C is used.S When an NT20S or NT600S which uses direct connection ver. 5 is used.With conventional models, up to 50 indirect designation settings can be made perscreen, including both numeral display and (character) string display.S If the value set for [Length] (the number of digits to be displayed) is smaller thanthe number of characters in the specified character string memory table (stringtable), the specified number of characters is displayed from the first character ofthe (character) string.
The remaining characters are not displayed.S To display mark data or image data, specify the address of the mark data orimage data as shown below.Note that image data cannot be inserted into a (character) string when usingNT11S, NT20S, NT31, NT31C, NT600S, NT631, or NT631C.SettingABC<!FFFE>DisplayABCMark data at code FFFEReference: When there are no string to show, string input will be invisible.Therefore, with Support Tool, dotted-line frame is displayed in character foreground color enclosing string input.(This frame will not be displayed on PT.)This frame can not be set to off.
However, the dotted–line frame can be set to ONand OFF when printing screen image (refer to P461).221Touch Switches6-8Section 6-8Touch SwitchesWhen a touch switch is pressed, any of the nine functions shown below is executed. In addition to the general functions such as the input notification (notify bit) andthe screen switching (standalone) function, a variety of functions can be realizedincluding control codes used in combination with a data input element. (Touchswitches cannot be used for NT11S.)CAUTIONDo not use input functions such as PT touch switches for applicationswhere danger to human life or serious property damage is possible or foremergency switch applications.[Notify bit touch switch]PTSwitchON/OFFnotificationPC (PLC)(1) When a touch switch is pressed, the specified bit in the PC(PLC) goes ON/OFF.Set switches, reset switches, alternate switches, and momentaryswitches can be used.Specifiedbit goesON/OFF[Screen switching touch switch](1) When a touch switch is pressed, the screen is switched to thescreen with the specified screen number.Screen 1Screen 2SwitchSwitchingto screen 2[(Character) string input function touch switch](Character) string data input field(by (character) string input element)ABCABCDEF(1) When a touch switch is pressed, the label of the touch switch isstored in the (character) string input field.Note This type of touch switch is always used in combination with a(character) string input element.GHI[Pop-up window/keyboard function touch switch](1) When a touch switch (OPEN) is pressed, the specified windowStandard screen (base screen)(keyboard screen) is displayed on the screen presently disWindow/Keyboard screenplayed.(2) When a touch switch (CLOSE) is pressed, the window (keyboard screen) presently displayed closes.OPEN222CLOSETouch SwitchesSection 6-8[Control code input touch switch (Input key – Control)](1) When a touch switch is pressed, the input processing of the control code is executed as shown below.S 0 to 9 numeral keys:Data setting at the numeral setting input fieldStandard screenInput field1234S CLR key:Clearing the numeral setting input fieldSkey:ConfirmationS Arrow symbol key:Switching among continuous/overlapping screensMoving the cursor in the numeral setting input fieldNumeric keys can be created using the touch switches assignedthese control codes.Note These touch switches are always used with a numeral/(character) string input element.
(The element to be used differs according to the allocated control codes.)[Copy setting touch switch]Memorytable50COPY50(1) When a touch switch is pressed, the data in the memory table ora constant is copied to another memory table or input field.Copy SourceNumeral memory tableCharacter stringmemory table (Stringtable)ConstantCopy DestinationNumeral memory tableCharacter stringmemory table (Stringtable)Input field specified bycursor[Window move touch switch]Window moves(1) When a touch switch (window move touch switch) is pressed,the window can be moved by touch panel operation at PT.When you press the destination (center of the window will comehere), window will be moved to that position.Note Window move touch switch can be created only on window/keyboard screen.MOVE223Touch SwitchesSection 6-8[Cursor moving touch switch]Data input field 1Data input field 2Data input field 3(1) When a touch switch (cursor moving touch switch) in an inputfield is pressed, the cursor moves to that input field.Note The cursor moving touch switch should be specified whencreating a numeral or (character) string input element.
(Thecursor moving touch switch can be added later.)Input cursormovesInput cursormoves[Print screen function touch switch](1) When a touch switch is pressed, a hard copy of the screen isoutput to a printer.Printing screenhard copyPRINTOperation procedureSelection using the menu bar:[Objects] → [Touch Switch]Selection using the drawing toolbar:TerminologyLabelFrameColour – ON, OFFProperty setting[General]Position:Indicates the display position of a touch switch frame (the area whichsenses pressing of the switch.)(The reference point is at the upper left corner of the touch switchframe)Size:Indicates the size of a touch switch frame.Label:Specify whether or not a label is appended to a touch switch frame.Frame:Specify whether or not a frame is displayed for a touch switch.Shape:Specify the shape of a touch switch.Standard, Shadow, 3-Dimension, Rectangle, Circle,Polygon, SectorShow ON State:Specify the status when touch switch is pressed.
When this checkbox is ticked, touch switch will be lighten. (Not valid for 3-Dimension)224Touch SwitchesSection 6-8ColourFrame:Specify the color of a touch switch if [Frame] is selected.(Can only be set for PTs with color display.)White, black, blue, red, magenta, green, cyan, yellowON:Specify the display color of a touch switch which is ON.(Can only be set for PTs with color display.)(Setting is valid only when [Show ON state] is selected.)White, black, blue, red, magenta, green, cyan, yellowOFF:Specify the display color of a touch switch which is OFF.(Can only be set for PTs with color display.)Transparent, white, black, blue, red, magenta, green, cyan,yellow:Displays the dialog box used to edit a label.
Specify the touchswitch label.:Copies the I/O comment set to the lamp bit as a label.However, in case of notify bit touch switch, I/O comment set tothe notify bit is copied. (Copy source name is displayed at theright side of the button.)[Settings]Function:Specify the touch switch function. Select from the following ninefunctions.Notify bitSwitch screenInput key – ControlInput key – Window/KeyboardInput key – StringCopy settingCursor moveWindow move (Only available on Window/Keyboard Screen)Print screenThe setting contents differ depending on the selected touch switch function.For details of setting, refer to “Guidance”.[Light Function]Touch switch also has the light function like a lamp.AddressPC (PLC) Bit Address:Specify the bit at the PC (PLC) which drives a touchswitch ON/OFF.I/O Comment:Specify the comment of the PC (PLC) bit whichdrives a touch switch ON/OFF.225Touch SwitchesSection 6-8Lamp AttributesON Type:Specify the status of a touch switch which is ON.Light, Flash::Displays the dialog box used to specify the bit number.Displays an I/O comment table.Reference: To check lamp ON status on the editing screen, select [Simulate ON/OFF] from[View] menu.Additionaly, to view flashing display of lamp attribute, select [Simulate Flash] from[View] menu.
For details, refer to 5–1–3.Guidance[Common description]S The following shapes can be used for touch switch elements.(Selectable shapes vary according to the PT model.)StandardCircleShadowPolygon3-DimensionRectangleSectorAlthough [Standard] and [Rectangle] have the same shape, how the touch switchframe is defined differs between them.