Главная » Просмотр файлов » H134-E1-01A E5_N UsersManual

H134-E1-01A E5_N UsersManual (986777), страница 22

Файл №986777 H134-E1-01A E5_N UsersManual (Техническая документация) 22 страницаH134-E1-01A E5_N UsersManual (986777) страница 222015-07-23СтудИзба
Просмтор этого файла доступен только зарегистрированным пользователям. Но у нас супер быстрая регистрация: достаточно только электронной почты!

Текст из файла (страница 22)

1 display (see note) and the set point and “end” will be alternately displayed on theNo. 2 display at 0.5 s intervals.NoteOne of the following displays: PV/SP, PV only, or PV/MV.120.1Displayed alternately.end120.0Program End OutputWhen the “program pattern” parameter is changed from OFF to STOP orCONT, the “alarm 1 output assignment” parameter will automatically be set tothe END output. The ALM1 indicator will not light while the END output is set.(When the “program pattern” parameter is changed from STOP or CONT toOFF, the “alarm 1 output assignment” parameter will automatically be initialized to ALM1.) The output assignment parameters can also be used to assignthe program END output to any output.The program END output is also provided in communications status.Clearing the Program End StatusThe program END output and display will be cleared when the “program start”parameter is changed from STRT to RSET.

The setting is changed from STRTto RSET while the “program start” parameter is displayed.The program END status can also be cleared using an event. If the programstart function is assigned to an event, however, the program end status cannotbe cleared from the “program start” parameter display, which will function onlyas a monitor display.Operating ProcedurePerform the following procedure to use the simple program function.In this example, the program pattern will be set to STOP, the soak time to10 min, and the wait band to 3.Wait band = 3Set pointPVRSET → STRTSoak time = 10 minSTOPEND displayEND output107Using the Simple Program FunctionSection 4-15Operation LevelC25PV/SP100Initial Setting Levelin-tInput type1.

Press the O key for at least three seconds to move from the operationlevel to the initial setting level.5Initial Setting Levelptrn2. Select the “program pattern” parameter by pressing the M key.Program Patternoff3. Use the U key to set the parameter to STOP.ptrnstopOperation LevelC25PV/SP4. Press the O key for at least one second to move from the initial settinglevel to the operation level.1005. Press the O key to move from the operation level to the adjustment level.Adjustment LevelAdjustment levell.adj display6. Select the “soak time” parameter by pressing the M key.Adjustment LevelsoakSoak time17.

Use the U key to set the parameter to 10. (The soak time unit is set in“soak time unit” parameter in the advance function setting level. The default is m (minutes).soak108. Select the “wait band” parameter by pressing the M key.Adjustment Levelwt-bWait bandoff9. Use the U key to set the parameter to 3.0.wt-b3.010.

Press the O key to move from the adjustment level to the operation level.Operation LevelC25100108PV/SPSection 4-15Using the Simple Program Function4-15-3 Application Example Using a Simple ProgramThe program will be started by changing the setting of the “program start”parameter. The following example shows using a simple program with the program pattern set to STOP.Wait bandSet pointPVSoak timeSoak timeSoak timeEND displayEND outputRUNSTOP RUNRUN/STOPstatusSTRTRSETRSETSTRTSTRTProgramstart(1)Timing(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(2)(3)(4)(5) (6)(7) (8)(9)(10)Description• The “program start” parameter was changed from RSET to STRT using either an event or key operations.• The RUN/STOP status automatically changes to RUN mode when the above operation is performed.• The “program start” parameter was changed from STRT to RSET using either an event or key operationsbefore the soak time expired.• The RUN/STOP status automatically changes to STOP mode when the above operation is performed.• The “program start” parameter is again changed from RSET to STRT using either an event or key operations.• The RUN/STOP status will automatically change to RUN mode when the above operation is performed.• The RUN/STOP status automatically changes to STOP mode when soak time expires.• END flashes on the No.

2 display and the program END output turns ON.• The “program start” parameter is changed from STRT to RSET using either an event or key operations.• The END display is cleared and the program END output turns OFF.• Key operations are used to switch the RUN/STOP status to RUN with the “program start” parameter set toRSET (stopped).• Normal control operation is started.• The “program start” parameter is changed from RSET to STRT after the process value stabilizes.• The RUN/STOP status remains as RUN.• Key operations are used to change the RUN/STOP status to STOP (during program operation).• Measuring the soak time is continued within the wait band. (Measuring the soak time stops when the process value leaves the wait band.)• Key operations are used to change the RUN/STOP status to RUN.• Measuring the soak time is continued within the wait band (continuing from the time between (7) and (9)).• The RUN/STOP status automatically changes to STOP mode when the measured time reaches the soaktime.• END flashes on the No.

2 display and the program END output turns ON.109Section 4-16Output Adjustment Functions4-16 Output Adjustment Functions4-16-1 Output Limits• Output limits can be set to control the output using the upper and lowerlimits to the calculated MV.• The following MV takes priority over the MV limits.Manual MVMV at stopMV at PV errorOutput100%MV upper limitMV lower limit0%• For heating/cooling control, upper and lower limits are set of overall heating/cooling control. (They cannot be set separately for heating/cooling.)OutputHeating MVCooling MVMV lower limitMV upper limit4-16-2 MV at Stop• The MV when control is stopped can be set.For heating/cooling control, the MV at stop will apply to the cooling side ifthe MV is negative and to the heating side if the MV is positive.The default is 0.0, so an MV will not be output for either standard or heating/cooling control.ParameterMV at stopNote110Setting range−5.0 to 105.0 for standard%control−105.0 to 105.0 (heating/cooling control)UnitDefault0.00The order of priority is as follows: Manual MV > MV at stop > MV at PV error.Section 4-16Output Adjustment Functions4-16-3 MV at PV Error• The MV to be output for input errors or heater burnout errors can be set.The MV at stop takes priority when stopped and the manual MV takes priority in manual mode.ParameterMV at PV errorNoteSetting rangeUnit−5.0 to 105.0 for standard%control−105.0 to 105.0 (heating/cooling control)Default0.0The order of priority is as follows: Manual MV > MV at stop > MV at PV error.• The order of priority of the MVs is illustrated in the following diagram.MV upper limitMV at PV ErrorManual MVRUN/STOPManipulated variableOutputPIDcalculationsInput errorAuto/manual switchTimeMV at StopMV lower limit111SECTION 5ParametersThis section describes the individual parameters used to setup, control, and monitor operation.5-1Conventions Used in this Section .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1145-1-1Meanings of Icons Used in this Section . . . . . . . . . . . . . . . . . . . . . .1145-1-2About Related Parameter Displays . . . . . . . . . . . . . . . . . . . .

. . . . . .1145-1-3About the Order in Which Parameters Are Described in This Section1145-2Protect Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1155-3Operation Level. . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1185-4Adjustment Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1295-5Manual Control Level . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . .1445-6Initial Setting Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1455-7Advanced Function Setting Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1575-8Communications Setting Level . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182113Section 5-1Conventions Used in this Section5-1Conventions Used in this Section5-1-1Meanings of Icons Used in this SectionDescribes the functions of the parameter.FunctionDescribes the setting range and default of the parameter.SettingUsed to indicate parameters used only for monitoring.MonitorDescribes the parameter settings, such as those for Operation Commands,and procedures.OperationUsed to indicate information on descriptions in which the parameter is used orthe names of related parameters.See5-1-2About Related Parameter DisplaysParameters are displayed only when the conditions for use given on the rightof the parameter heading are satisfied.

Характеристики

Тип файла
PDF-файл
Размер
3,78 Mb
Тип материала
Высшее учебное заведение

Список файлов учебной работы

Свежие статьи
Популярно сейчас
Почему делать на заказ в разы дороже, чем купить готовую учебную работу на СтудИзбе? Наши учебные работы продаются каждый год, тогда как большинство заказов выполняются с нуля. Найдите подходящий учебный материал на СтудИзбе!
Ответы на популярные вопросы
Да! Наши авторы собирают и выкладывают те работы, которые сдаются в Вашем учебном заведении ежегодно и уже проверены преподавателями.
Да! У нас любой человек может выложить любую учебную работу и зарабатывать на её продажах! Но каждый учебный материал публикуется только после тщательной проверки администрацией.
Вернём деньги! А если быть более точными, то автору даётся немного времени на исправление, а если не исправит или выйдет время, то вернём деньги в полном объёме!
Да! На равне с готовыми студенческими работами у нас продаются услуги. Цены на услуги видны сразу, то есть Вам нужно только указать параметры и сразу можно оплачивать.
Отзывы студентов
Ставлю 10/10
Все нравится, очень удобный сайт, помогает в учебе. Кроме этого, можно заработать самому, выставляя готовые учебные материалы на продажу здесь. Рейтинги и отзывы на преподавателей очень помогают сориентироваться в начале нового семестра. Спасибо за такую функцию. Ставлю максимальную оценку.
Лучшая платформа для успешной сдачи сессии
Познакомился со СтудИзбой благодаря своему другу, очень нравится интерфейс, количество доступных файлов, цена, в общем, все прекрасно. Даже сам продаю какие-то свои работы.
Студизба ван лав ❤
Очень офигенный сайт для студентов. Много полезных учебных материалов. Пользуюсь студизбой с октября 2021 года. Серьёзных нареканий нет. Хотелось бы, что бы ввели подписочную модель и сделали материалы дешевле 300 рублей в рамках подписки бесплатными.
Отличный сайт
Лично меня всё устраивает - и покупка, и продажа; и цены, и возможность предпросмотра куска файла, и обилие бесплатных файлов (в подборках по авторам, читай, ВУЗам и факультетам). Есть определённые баги, но всё решаемо, да и администраторы реагируют в течение суток.
Маленький отзыв о большом помощнике!
Студизба спасает в те моменты, когда сроки горят, а работ накопилось достаточно. Довольно удобный сайт с простой навигацией и огромным количеством материалов.
Студ. Изба как крупнейший сборник работ для студентов
Тут дофига бывает всего полезного. Печально, что бывают предметы по которым даже одного бесплатного решения нет, но это скорее вопрос к студентам. В остальном всё здорово.
Спасательный островок
Если уже не успеваешь разобраться или застрял на каком-то задание поможет тебе быстро и недорого решить твою проблему.
Всё и так отлично
Всё очень удобно. Особенно круто, что есть система бонусов и можно выводить остатки денег. Очень много качественных бесплатных файлов.
Отзыв о системе "Студизба"
Отличная платформа для распространения работ, востребованных студентами. Хорошо налаженная и качественная работа сайта, огромная база заданий и аудитория.
Отличный помощник
Отличный сайт с кучей полезных файлов, позволяющий найти много методичек / учебников / отзывов о вузах и преподователях.
Отлично помогает студентам в любой момент для решения трудных и незамедлительных задач
Хотелось бы больше конкретной информации о преподавателях. А так в принципе хороший сайт, всегда им пользуюсь и ни разу не было желания прекратить. Хороший сайт для помощи студентам, удобный и приятный интерфейс. Из недостатков можно выделить только отсутствия небольшого количества файлов.
Спасибо за шикарный сайт
Великолепный сайт на котором студент за не большие деньги может найти помощь с дз, проектами курсовыми, лабораторными, а также узнать отзывы на преподавателей и бесплатно скачать пособия.
Популярные преподаватели
Добавляйте материалы
и зарабатывайте!
Продажи идут автоматически
7041
Авторов
на СтудИзбе
260
Средний доход
с одного платного файла
Обучение Подробнее