DifferenceNew models:Smoothing processing is not possible for marks.Conventional models:Smoothing processing is possible for marks. Conversion result, error message and corrective actionStatus beforeConversionWith a conventionalmodel, smoothingprocessing is specified for a mark.Status afterConversionWith a new model,smoothing processing is invalid for amark.Error MessageCorrective Action[Fixed Display Mark]–smoothing not supported.
It is ignored.Correction not necessary.Correction related to the system keypadIf a system keypad is converted between a conventional and a new model, conversion is executed in the manner shown below due to differences in the handling ofthe system keypad between them. DifferenceNew models:The system keypad cannot be set.Conventional models:Numeric keys can be created automatically by setting asystem keypad. Conversion result, error message and corrective actionStatus beforeConversionWith a conventionalmodel, a systemkeypad is automatically created with anumeral setting inputscreen.482Status afterConversionWith a new model,the system keypadis invalid and thusnot displayed.Error MessageCorrective Action––Either copy the registered keyboard from thesymbol manager (refer to6-10), or create numerickeys which are equivalent to a system keypadusing the touch switchcontrol code input function (Refer to 6-8-5).Data ConversionAppendix ACorrection of alarm list/history touch switchesIf a touch switch for alarm list/history is converted between a conventional and anew model, conversion is executed in the manner shown below due to differencesin the handling of this kind of touch switch between them.
DifferenceNew models:Control touch switches are annexed to alarm lists/histories; correction is possible only with regard to theposition of the touch switches.Conventional models:Control touch switches can be handled as independenttouch switches (to be associated with alarm lists/histories).
Their position, size, label, etc. can be edited asdesired. Conversion result, error message and corrective actionStatus beforeConversionStatus afterConversionWith a conventionalmodel, an alarm list/history is registeredfor a screen andtouch switches areassociated with it.With a new model,the associated touchswitches are deletedand the controltouch switches (inthe initial state) areautomaticallycreated.[E]Touch Switch function type is not supported. It is discarded.[W]The associatedtouch switches ofthe alarm has beendiscarded and component touchswitches have beencreated.Adjust the position ofcontrol touch switches ifnecessary.
(Refer to6-3.)With a conventionalmodel, an alarm list/history is registeredfor a screen (withoutcontrol touchswitches).With a new model,control touchswitches (in the initial state) are automatically created.[W]The associatedtouch switches ofthe alarm has beendiscarded and component touchswitches have beencreated.If control touch switchesare not necessary, deletethem by setting in thealarm list/history properties. (Refer to 6-3.)With a new model,touch switches areautomaticallycreated by registering alarm list/historyto the symbol manager.With a conventionalmodel, all controltouch switches aredeleted.[W]The componentTouch Switches ofthe Alarm List will bediscarded.Create the control touchswitches using the touchswitch control code inputfunction and associatethem with the alarm list/history. (Refer to 6-8-5.)Error MessageCorrective ActionCorrection of touch switch position and sizeTouch switch size differs between NT20S, NT600S, NT620S and other PT models.Therefore, when the data of NT20S, NT600S, NT620S is converted to the data forother PT models, touch switch position and size may change.
Conversion result, error message and corrective actionStatus beforeConversionStatus afterConversionTouch switch positionand size maychange.Error Message––Corrective ActionCorrect the touch switchposition and size asneeded. (Refer to 6-8)483Data ConversionAppendix ACorrection related to a touch switch for which a pop-up window/keyboard function is setIf a touch switch assigned the pop-up window/keyboard function is converted between a conventional and a new model, conversion is executed in the mannershown below due to differences in the range of screen numbers of the touch switchwindow/keyboard screen. DifferenceNew models:Screen numbers of window/keyboard screen:1 to 3999Conventional models:Screen numbers of window/keyboard screen:1900 to 1979 Conversion result, error message and corrective actionStatus beforeConversionStatus afterConversionWith a new model,the touch switch forwhich a pop-up window/keyboard function is set is registered to the symbolmanager.With a conventionalmodel, the window/keyboard screennumber is correctedto “1900”.Error MessageCorrective ActionInput Key-Window/Keyboard screennumber is not withinthe valid range.Minimum value restored.Create the window/keyboard screen for ascreen number in therange 1900 to 1979 andcorrect the window/keyboard screen number setfor the touch switch accordingly.
(Refer to 5-4,6-8-4.)Correction related to the touch switch for which the copy function is setIf a touch switch assigned the copy function is converted between a conventionaland a new model, conversion is executed in the manner shown below due to differences in the range of numeric values which can be input. DifferenceNew models:As a constant for the copy setting function, a numericvalue of up to 10 digits can be input.Conventional models:As a constant for the copy setting function, a numericvalue of up to 8 digits can be input.
Conversion result, error message and corrective action484Status beforeConversionStatus afterConversionWith a new model, atouch switch forwhich the copy setting function is setwith a numeric valuegreater than100000000 or smaller than –10000000specified is registered to the symbolmanager.With a conventionalmodel, a valuegreater than100000000 is corrected to 99999999or a value smallerthan –10000000 iscorrected toF0000000.Error MessageCorrective Action[W]Constant Value isout of limit. Maximum value restored.Correct the screen dataor the program in thehost so that a constant ofup to 8 digits suffices.(Refer to 6-8-6.)Data ConversionAppendix ACorrection related to the lamp label (ON state)If a lamp’s label is converted between a conventional and a new model, conversionis executed in the manner shown below due to difference of label color setting.
DifferenceNew models:ON state and OFF state can be set independently.Background color is transparent only.Conventional models:Only foreground color can be set. (OFF, ON/Flash hassame color). Background color can be set as desired. Conversion result, error message and corrective actionStatus beforeConversionWith a conventionalmodel;“Background”: Any“Foreground”: AnyStatus afterConversionWith a new model;“Background”:Transparent“OFF State”: Sameas “Foreground”“ON State”: BlackError MessageCorrective Action––This will lead to an invisible label when the lampis ON. Select the lampand choose [Edit] – [EditObject] and double clickat the label. Thenchange the label ONstate color to differentcolor.Correction related to the maximum and minimum limit check function for numeral inputIn the conversion of the data between a conventional and a new model, conversionis executed in the manner shown below due to differences in the range of numeralwhich can be input.
DifferenceNew models:A numeric value of up to 10 digits can be input for themaximum/minimum limit.Conventional models:A numeric value of up to 8 digits can be input for themaximum/minimum limit. Conversion result, error message and corrective actionStatus beforeConversionStatus afterConversionWith a new model, anumeral setting inputfield for which a numeric value greaterthan 100000000 orsmaller than–10000000 is specified as a maximumor minimum limit isregistered to thesymbol manager.With a conventionalmodel, maximumand minimum valuegreater than 8 digitswill be reset.Error Message[W]Numeral Input Maximum value is out oflimit.
Default valuesrestored for maximum and minimum.Corrective ActionCreate a new numeralsetting input field. Correct the screen data orthe program in the hostso that a constant of upto 8 digits suffices. (Refer to 6-4-1, 6-4-3.)485Data ConversionAppendix ACorrection related the number of digits for numeral inputIn the conversion of the data between a conventional and a new model, conversionis executed in the manner shown below due to differences in the range of numericvalues which can be input. DifferenceNew models:A numeric value of up to 10 digits can be input.Conventional models:A numeric value of up to 8 digits can be input. Conversion result, error message and corrective actionStatus beforeConversionStatus afterConversionWith a new model, anumeral setting inputfield (or a thumbwheel switch) forwhich a numeric value exceeding 8 digits is input is registered to the symbolmanager.With a conventionalmodel, a numeralsetting input field (ora thumbwheelswitch) of greaterthan 8 digits is discarded.Error MessageCorrective Action[E][Numeral Input] –Total number of integer and decimal exceeds limit.