Mount it in the direction shown in the above diagram. Ifthe Terminal Cover is mounted in the opposite direction, propermounting of the fixtures may not be possible.Adapter(sold separately)E5CN-UFor Front-mounting Socket(Panel mounting is also possible.)Waterproof packingPanelE5CN1. The Panel Mounting Adapter is also included with the E5CN-U.There is no waterproof packing included with the E5CN-U.2. Insert the E5CN/E5CN-U into the mounting hole in the panel.Digital Temperature ControllersE5@N47Removing the Temperature Controller fromthe Case3.
When inserting the E5AN/E5EN Temperature Controller, check tomake sure that the sealing rubber is in place. Then, while pushingthe front panel into place, turn the Phillips screwdriver to the rightin the opposite direction used when removing the panel to tightenthe screws on the top and bottom surfaces (tightening torque: 0.3to 0.5 N·m).
Make sure that electronic components do not comeinto contact with the case.E5CNThe Temperature Controller can be removed from the case toperform maintenance without removing the terminal leads. This ispossible for only the E5CN, and not for the E5CN-U.Precautions when WiringTool insertion holeFlat-blade screwdriver(Unit: mm)(1)20 min.ALM1ALM2ALM3HAPVOUT1(3)OUT2• Separate input leads and power lines in order to prevent externalnoise.• Use wires with a gage of AWG24 (cross-sectional area: 0.205mm2) to AWG14 (cross-sectional area: 2.081 mm2) twisted-paircable (stripping length: 5 to 6 mm).• Use crimp terminals when wiring the terminals.• Tighten the terminal screws to a torque of 1.13 to 1.36 N·m.• Use the following types of crimp terminals for M3.5 screws.STOPCMWMANU(2)(1)2.00.4SVE5 CN1.
Insert the tool into the two tool insertion holes (one on the top andone on the bottom) and release the hooks.2. Insert the tool in the gap between the front panel and rear case,and pull out the front panel slightly. Hold the top and bottom of thefront panel and carefully pull it out toward you, without applyingunnecessary force.3. When inserting the E5CN, check to make sure that the sealingrubber is in place and push the E5CN toward the rear case until itsnaps into position. While pushing the E5CN into place, pushdown on the hooks on the top and bottom surfaces of the rearcase so that the hooks are securely locked in place. Be sure thatelectronic components do not come into contact with the case.7.2 mm max.7.2 mm max.• Do not remove the terminal block.
Doing so will result inmalfunction or failure.E5EN/E5ANPrepare a Phillips screwdriver suitable for the screw on the frontpanel to remove the Temperature Controller.(1)(1)(2)(2)(3)(3)E5ENE5AN1. Push on the hooks on the top of the front panel, and at the sametime, turn the Phillips screwdriver to the left to loosen the screwon the bottom of the front panel.2. Pull out the front panel gripping both sides.ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.To convert millimeters into inches, multiply by 0.03937.
To convert grams into ounces, multiply by 0.03527.Cat. No. H136-E1-01A In the interest of product improvement, specifications are subject to change without notice.OMRON CorporationIndustrial Automation CompanyControl Devices Division H.Q.Analog Controller DivisionShiokoji Horikawa, Shimogyo-ku,Kyoto, 600-8530 JapanTel: (81)75-344-7080/Fax: (81)75-344-71891105.