H134-E1-01A E5_N UsersManual (986777), страница 37
Текст из файла (страница 37)
See note 1.See note 1. See note 1.4-20, 0-20 4-20−1999 to 9,999None0NoneDefault0.0%Manual Control LevelParametersManual MVCharactersSetting (monitor) value−5.0 to 105.0 (standard)−105.0 to 105.0 (heating/cooling)DisplayUnitSet valueUnitSet valueAdvanced Function Setting LevelParametersParameter initializationNumber of multi-SPusesEvent input assignment 1CharactersSetting (monitor) valueinitOFF, FACTev-m0 to 2ev-1NONE:STOP:MANU:PRST:NoneRUN/STOPAuto/manual switchProgram start (Seenote 5.)Displayoff, factDefaultOFFNone1Nonenone,NONEstop,manu, prstNone213Appendix AParametersEvent input assignment 2CharactersSetting (monitor) valueev-2NONE: NoneSTOP: RUN/STOPMANU: Auto/manual switchPRST: Program start (Seenote 5.)DisplayDefaultnone,STOPstop,manu, prstUnitNoneMulti-SP usesSP ramp time unitmspuspruoff, ons, mOFFMNoneNoneStandby sequenceresetAlarm 1 close inalarmrestOFF, ONS: EU/secondM: EU/minuteCondition A, condition Ba, bCondition A Noneal1nN-O: Open in alarmN-C: Close in alarmn-o, n-cN-ONoneAlarm 1 hysteresisalh1Multi-input: 0.1 to 999.90.2Analog input: 0.01 to 99.990.02°C or °F(See note6.)%FSN-ONone0.2°C or °F(See note6.)0.02N-O%FSNoneAlarm 2 close inalarmAlarm 2 hysteresisal2nAlarm 3 close inalarmal3nAnalog input: 0.01 to 99.99N-O: Open in alarmN-C: Close in alarmAlarm 3 hysteresisalh3Multi-input: 0.1 to 999.90.2Analog input: 0.01 to 99.990.02°C or °F(See note6.)%FSONOFFNoneNonealh2HB ON/OFFhbuHeater burnout latch hblN-O: Open in alarmN-C: Close in alarmMulti-input: 0.1 to 999.9OFF, ONOFF, ONn-o, n-cn-o, n-coff, onoff, onHeater burnout hysteresishbh0.1 to 50.00.1AST stable rangeαst-balfa0.1 to 999.90.00 to 1.0015.00.65°C or °FNoneInput digital filterinfAdditional PV display pvad0.0 to 999.9OFF, ON0.0OFFSecondNoneoff, onMV displayAutomatic displayreturn timeo-dpretOFF, ONOFF or 1 to 99off, onoff, 1 to99OFFOFFNoneSecondAlarm 1 latchAlarm 2 latcha1lta2ltOFF, ONOFF, ONoff, onoff, onOFFOFFNoneNoneAlarm 3 latcha3ltMove to protect level prlttimeInput error outputseroOFF, ON1 to 30off, onOFF3NoneSecondOFF, ONoff, onOFFNoneCold junction compensation methodcjcOFF, ONoff, onONNoneMB command logicswitchingrlrvOFF, ONoff, onOFFNone214Set valueAppendix AParametersPV change colorCharactersSetting (monitor) valuecolrOrange, Red, GreenDisplayorg, red,grnRed to Green: When ALM1 is r-glit,Green to Red: When ALM1 is g-rlitRed to Green to Redr-g.rWithin PV stable band:GreenOutside stable band: RedGreen to Orange to Redg-o.rWithin PV stable band:GreenOutside stable band: Green,RedOrange to Green to Redo-g.rWithin PV stable band:GreenOutside stable band: Green,RedDefaultREDUnitNonePV stable bandpv-bMulti-input: 0.1 to 999.95.0Analog input: 0.01 to 99.995.00°C or °F(See note6.)%FSAlarm 1 ON delaya1on0SecondAlarm 2 ON delaya2on0SecondAlarm 3 ON delaya3on0SecondAlarm 1 OFF delaya1of0SecondAlarm 2 OFF delaya2of0 to 999 (0: ON delay disabled)0 to 999 (0: ON delay disabled)0 to 999 (0: ON delay disabled)0 to 999 (0: OFF delay disabled)0 to 999 (0: OFF delay disabled)0SecondAlarm 3 OFF delaya3of0 to 999 (0: OFF delay disabled)0SecondInput shift typeistpINS1: Temperature input 1point shiftINS2: Temperature input 2point shiftOFF, ONins1, ins2 INS1Noneoff, onOFFNoneOFF, ONoff, onOFFNoneMV at stop and error mvstadditionAuto/manual selectamadadditionRTHS alarm userthsuOFF, ONOFF, ONoff, onoff, onOFFONNoneNoneHS alarm latchHS alarm hysteresishslhshOFF, ON0.1 to 50.0off, onOFF0.1NoneALBA detection timelba0 to 9999 (0: LBA function disabled)0SecondLBA levellbalMulti-input: 0.1 to 999.98.0°C or °F(See note6.)LBA bandlbabAnalog input: 0.01 to 99.99Multi-input: 0.0 to 999.910.003.0%FS°C or °F(See note6.)Analog input: 0.00 to 99.990.20%FSSet value215Appendix AParametersControl output 1assignmentControl output 2assignmentAlarm 1 assignmentAlarm 2 assignmentAlarm 3 assignment(E5AN/E5EN only)Character selectSoak time unit216CharactersSetting (monitor) valueout1When control output 1 is apulse output (See note 2.):NONE: No assignmentO:Control output (heating)C-O: Control output (cooling)ALM1: Alarm 1ALM2: Alarm 2ALM3: Alarm 3P.END: Program end output(See note 4.)When control output 1 is a linear output (See note 2.):NONE: No assignmentO:Control output (heating)C-O: Control output (cooling)out2alm1alm2alm3cselt-uDisplayODefaultUnitNoneNONENoneALM1NoneALM2NoneALM3NoneONMNoneNonenoneoc-oalm1alm2alm3p.endnoneoc-oNONE: No assignmentO:Control output (heating)C-O: Control output (cooling)ALM1: Alarm 1ALM2: Alarm 2ALM3: Alarm 3P.END: Program end output(See note 4.)NONE: No assignmentO:Control output (heating)C-O: Control output (cooling)ALM1: Alarm 1ALM2: Alarm 2ALM3: Alarm 3P.END: Program end output(See note 4.)noneoNONE: No assignmentO:Control output (heating)C-O: Control output (cooling)ALM1: Alarm 1ALM2: Alarm 2ALM3: Alarm 3P.END: Program end output(See note 4.)NONE: No assignmentO:Control output (heating)C-O: Control output (cooling)ALM1: Alarm 1ALM2: Alarm 2ALM3: Alarm 3P.END: Program end output(See note 4.)noneoOFF, ONM: Minutes; H: Hoursoff, onm, hc-oalm1alm2alm3p.endnoneoc-oalm1alm2alm3p.endc-oalm1alm2alm3p.endnoneoc-oalm1alm2alm3p.endSet valueAppendix AParametersAlarm SP selectionCharactersSetting (monitor) valuealspSP-M: Ramp set pointSP:Set pointMove to calibrationlevelcmovDisplaysp-m, sp−1999 to 9,999DefaultSP-MUnitNone0NoneSet valueProtect LevelParametersCharactersMove to protect level pmovOperation/adjustoaptment protectSetting (monitor) valueDisplayDefaultUnit−1999 to 9,9990 to 300NoneNone1NoneInitial setting/communications protecticpt0 to 2Setting change protectwtptOFF, ONoff, onOFFNoneParameter maskpmskenablePassword to move to prlpprotect levelOFF, ONoff, onONNone0NoneDefaultCompoWay/F(SYSWAY)UnitNone−1999 to 9,999Set valueCommunications Setting LevelParametersProtocol settingCharactersSetting (monitor) valuepselCompoWay/F (SYSWAY),Modbus (See note 3.)Displaycwf, modCommunicationsUnit No.Communicationsbaud rateu-no0 to 991Nonebps1.2, 2.4, 4.8, 9.6, 19.2, or 38.4 1.2, 2.4,4.8, 9.6,19.2, 38.49.6kbpsCommunicationsdata lengthlen7, 87BitCommunicationsstop bitsCommunicationsparitySend data wait timesbit1, 22BitprtyNone, Even, OddEvenNonesdwt0 to 9920msnone,even, oddSet value217Appendix ANote(1)Transfer outputtypeSetting (monitor) rangeSet pointSP lower limit to SP upper limitDefault (transfer outputupper/lower limits) (Seenote 1.1.)SP upper limit/lower limitSet point during SPrampPVSP lower limit to SP upper limitSP upper limit/lower limitEUTemperature: Sensor settingrange lower limit to sensor setting range upper limitSensor setting range upper/lower limitEUScaling upper/lower limitEU100.0/0.0%100.0/0.0%Analog: Scaling lower limit toscaling upper limitMV monitor (heating) Standard: −5.0 to 105.0Heating/cooling: 0.0 to 105.0MV monitor (cooling) 0.0 to 105.0UnitEU(1.1) Initialized when the transfer output type is changed.Initialized if the input type, temperature unit, scaling upper/lower limit, or SP upper/lower limit is changed when the transfer output type is SP, ramp SP, or PV.(When initialized by the initializing settings, it is initialized to 100.0/0.0.)(2) The setting range depends on whether control output 1 is a linear output or pulse output.(3) When setting CWF, either CompoWay/F or SYSWAY can be used as the communications protocol.(CompoWay/F and SYSWAY are automatically identified by the command frames.)(4) P.END (program end output) can be set when the program pattern is not set to 0 (OFF).(5) PRST (program start) can be set when the program pattern is not set to 0 (OFF).(6) Set “none” as the unit for Controllers with Analog Inputs.218Appendix ASensor Input Setting Range, Indication Range, Control RangeControllers withThermocouple/ResistanceThermometer MultiinputsInput typeSpecifications Set valueResistance ther- Pt1000mometer1Input temperature range−200 to 850 (°C)/−300 to1,500 (°F)−199.9 to 500.0 (°C)/−199.9to 900.0 (°F)0.0 to 100.0 (°C)/0.0 to 210.0(°F)Input indication range−220 to 870 (°C)/−340 to1,540 (°F)−199.9 to 520.0 (°C)/−199.9to 940.0 (°F)−20.0 to 120.0 (°C)/−40.0 to250.0 (°F)3−199.9 to 500.0 (°C)/−199.9to 900.0 (°F)−199.9 to 520.0 (°C)/−199.9to 940.0 (°F)40.0 to 100.0 (°C)/0.0 to 210.0 −20.0 to 120.0 (°C)/−40.0 to(°F)250.0 (°F)5−200 to 1,300 (°C)/−300 to2,300 (°F)−20.0 to 500.0 (°C)/0.0 to900.0 (°F)−100 to 850 (°C)/−100 to1,500 (°F)−20.0 to 400.0 (°C)/0.0 to750.0 (°F)2JPt100ThermocoupleK6J789−200 to 400 (°C)/−300 to 700 −220 to 420 (°C)/−340 to 740(°F)(°F)10−199.9 to 400.0 (°C)/−199.9to 700.0 (°F)E11L12U13−20 to 620 (°C)/−40 to 1,140(°F)−100 to 850 (°C)/−100 to−120 to 870 (°C)/−140 to1,500 (°F)1,540 (°F)−200 to 400 (°C)/−300 to 700 −220 to 420 (°C)/−340 to 740(°F)(°F)−199.9 to 400.0 (°C)/−199.9 −199.9 to 420.0 (°C)/−199.9to 700.0 (°F)to 740.0 (°F)−200 to 1,300 (°C)/−300 to−220 to 1,320 (°C)/−340 to2,300 (°F)2,340 (°F)T14ES1B InfraredTemperatureSensorAnalog input−220 to 1,320 (°C)/−340 to2,340 (°F)−40.0 to 520.0 (°C)/−40.0 to940.0 (°F)−120 to 870 (°C)/−140 to1,540 (°F)−40.0 to 420.0 (°C)/−40.0 to790.0 (°F)−199.9 to 420.0 (°C)/−199.9to 740.0 (°F)0 to 600 (°C)/0 to 1,100 (°F)N15R160 to 1,700 (°C)/0 to 3,000(°F)−20 to 1,720 (°C)/−40 to3,040 (°F)S170 to 1,700 (°C)/0 to 3,000(°F)−20 to 1,720 (°C)/−40 to3,040 (°F)B1810 to 70°C19100 to 1,800 (°C)/300 to3,200 (°F)0 to 90 (°C)/0 to 190 (°F)60 to 120°C200 to 120 (°C)/0 to 240 (°F)115 to 165°C210 to 165 (°C)/0 to 320 (°F)0 to 1,820 (°C)/0 to 3,240(°F)−20 to 130 (°C)/−40 to 270(°F)−20 to 160 (°C)/−40 to 320(°F)−20 to 205 (°C)/−40 to 400(°F)140 to 260°C220 to 260 (°C)/0 to 500 (°F)−20 to 300 (°C)/−40 to 580(°F)0 to 50 mV23Any of the following ranges,by scaling:−1,999 to 9,999−199.9 to 999.9−5% to 105% of settingrange.
The display shows 1999 to 9999 (numeric rangewith decimal point omitted).219Appendix AControllers withAnalogInputsInput typeCurrent inputSpecifications Set value04 to 20 mAVoltage input0 to 20 mA1 to 5 V120 to 5 V0 to 10 V34Input temperature rangeAny of the following ranges,by scaling:−1,999 to 9,999−199.9 to 999.9−19.99 to 99.99−1.999 to 9.999Input indication range−5% to 105% of settingrange. The display shows−1999 to 9999 (numericrange with decimal pointomitted).• The default is 5 (°C/°F) for Controllers with Thermocouple/Resistance Thermometer Multi-Inputs and 0 forControllers with Analog Inputs.• The applicable standards for each of the above input ranges are as follows:K, J, T, E, N, R, S, B: JIS C1602-1995, IEC 584-1L:Fe-CuNi, DIN 43710-1985U:Cu-CuNi, DIN 43710-1985JPt100:JIS C 1604-1989, JIS C 1606-1989Pt100:JIS C 1604-1997, IEC 751Control Range• Resistance thermometer and thermocouple inputTemperature lower limit − 20°C to temperature upper limit + 20°C, or temperature lower limit − 40°C totemperature upper limit + 40°C• ES1B input:Same as input indication range• Analog input−5% to +105% of scaling range220Appendix ASetting Levels DiagramThis diagram shows all of the setting levels.
To move to the advanced function setting level and calibrationlevel, you must enter passwords. Some parameters are not displayed depending on the protect level settingand the conditions of use.Control stops when you move from the operation level to the initial setting level.Power ONStarted in manual mode.Started in automatic mode.Press the O Keyfor at least 1 s.Operation LevelCManualmode(Seenote3.)Press theO Key less than 1 s.a-mPress the O Key forat least 1 s; displaywill flash.Press the Ol Key forat least 3 s while a-mis displayed.Manual ControlLevelPress theO Keyfor atleast 1 s.Press the O +M keys; displaywill flash.Adjustment LevelPress the O+ M Keys forat least 1 s.Press the O Key for atleast 1 s; display will flash.Press the O Key for at100least 3 s.C25(Seenote 1.)Initial Setting LevelCControl stops.Communications SetPress the ting Level25100Press the O +M Keys for atleast 3 s.