. . . . . . . . . . . . . . . NoNoNoReset . . . . . . . . . . . . . . NoNoNoAlternate . . . . . . . . . . . NoNoNoMomentary . . . . . . . . . NoNoNoMomentaryNoNoNoYESOverlapping of a notification and other kind of touch switch:SetReset AlternateMomentaryScreen switch .
. . . . . . NoNoNoYESControl code input . . . NoNoNoYESPopup keyboard . . . . . NoNoNoNoCharacter string input NoNoNoYESCopy setting . . . . . . . . NoNoNoYESCursor movement . . . NoNoNoYESScreen print . . . . . . . . NoNoNoYESOverlapping of two other kinds of touch switches:Neither function operates.Overlapping of two notification touch switches:SetReset AlternateSet . . . . . . .
. . . . . . . . . YESYESYESReset . . . . . . . . . . . . . . YESYESYESAlternate . . . . . . . . . . . YESYESYESMomentary . . . . . . . . . YESYESYESMomentaryYESYESYESYESOverlapping of a notification and other kind of touch switch:SetReset AlternateMomentaryScreen switch . . . .
. . . YESYESYESYESControl code input . . . YESYESYESYESPopup keyboard . . . . . YESYESYESQualifiedCharacter string input YESYESYESYESCopy setting . . . . . . . . YESYESYESYESCursor movement . . . YESYESYESYESScreen print . . . . . . . . YESYESYESYESOverlapping of two other kinds of touch switches:Neither function operates.449Appendix BCompatibility with Screen Data of Other PT ModelsItemNT30/NT30C, NT620S/NT620C/NT625CNT31/NT31C, NT631/NT631CPop-upwindowfunctiontouchswitchOnly Keyboard screen can be controlled.Window display position can not be changed.Local window1 or local window2 can be controlled.Window display position can be changed.Windowmove function touchswitchNot availableAvailableSystemprogramformemorylinkMemory link onlyShared with OMRON/Memory link (-V1 and later versions)Screendata formemorylinkOMRON screen data (data area allocation only, no allocation check)Memory link screen data (Allocation check is possible.)DeviceMonitorfunctionNot availableCan be used to switch the PC’s operating mode, display/changecontents of PC words, and display the error log.Mathematical functionNot availableCan be used to automatically execute up to 256 formulas registeredin mathematical table.(Operands (results) are automatically read from (written to) numeralmemory table entries or PC words.)Highspeed 1:NNT LinkNot available (Only the standard 1:N NT Link is supported.)Available (Both the standard and high-speed 1:N NT Link aresupported.)RecipefunctionNoneNormal screen: 1 max.; Multiple screens: 8 max.; Window screens:Not possibleAccessibleCS/CJ-series dataareasCIO areaTIM area (timer PVs)CNT area (counter PVs)DM areaEM area (current bank only)CIO areaHR areaWR area (work areas)TK area (task flags)TIM area (timer PVs)TU area (timer completion flags)CNT area (counter PVs)CU area (counter completion flags)DM areaEM area (current bank, banks 0 to C)Apart from the above, due to difference between PT models, it may be necessary to modify screen data and programs at the host.
For details, refer to the NT-series Support Tool Version 4 for Windows Operation Manual(V061-E1-j).450Appendix BCompatibility with Screen Data of Other PT ModelsDifferences between NT31/NT31C and NT631/NT631C Modelswithout the -V1 Suffix and PT Models with -V1ItemDrawingorder ofobjectsNT31/NT31C and NT631/NT631C (without -V1)DisplayDisplayObject TypesTopImage/library lampAlarm list/history frameTemporary inputString inputThumbwheelNumeral inputTrend graphBroken line graphAnalogue meterBar graphNumeral displayString displayFixed displayLampTouch switchImage/library dataScreen backgroundBottomBit15Word1413121110987Bit6543210Numeral/character string memory table entry No.(BCD or hexadecimal 4 digits)Word mWord m+1PT status notify bits00Word15Word141301211109876543210Numeral/character string memory table entry No.(BCD or hexadecimal 4 digits)Word mPT status notify bitsWindowcontrol areaObject TypesTopImage/library lampAlarm list/history frameTemporary inputString inputThumbwheelNumeral inputTrend graphBroken line graphBar graphNumeral displayString displayFixed displayLampTouch switchImage/library dataScreen backgroundBottomPT statusnotify areaNT31/NT31C and NT631/NT631C (with V1)Word m+1PT status notify bits000PT status notify bitsNotified Information1 (ON)Run0 (OFF)StopWord1 (ON)PT operation status0 (OFF)PT operation status14Not used14Not used13BatteryLowNormal13BatteryLowNormal12Screen switch strobeONOFF12Screen switch strobeONOFF11Numeral setting strobeONOFF11Numeral setting strobeONOFF10Character string setting strobeONOFF10Character string setting strobeONAlways 09Not usedAlways 0Always 015Notified Information15RunStopAlways 0OFF9Not usedAlways 08Not used8Not used7Printer operating statusPrintingStopped7Printer operating statusPrintingStopped6Backlight statusOFFLit/flashing6Backlight statusOFFLit/flashing5Global window open statusOpenClose4Local window 1 open statusOpenClose3Local window 2 open statusOpenCloseAlways 0NoneBitWordWord k1514131211109876543210Global windowScreen No.
(4-digit BCD or hexadecimal)Word k+1Global windowX coordinate (4-digit BCD or hexadecimal)Word k+2Global windowY coordinate (4-digit BCD or hexadecimal)Word k+3Local window1Screen No. (4-digit BCD or hexadecimal)Word k+4Local window1X coordinate (4-digit BCD or hexadecimal)Word k+5Local window1Y coordinate (4-digit BCD or hexadecimal)Word k+6Local window2Screen No. (4-digit BCD or hexadecimal)Word k+7Local window2X coordinate (4-digit BCD or hexadecimal)Word k+8Local window2Y coordinate (4-digit BCD or hexadecimal)451Appendix BCompatibility with Screen Data of Other PT ModelsItemWindowNT31/NT31C and NT631/NT631C (without -V1)S Only 1 window can be displayedS Display elements that can be registered on a windowNT31/NT31C and NT631/NT631C (with V1)S Up to 3 screens can be displayed (1 global window, 2 localwindows)Fixed displayS Display elements that can be registered on a windowTouch switch (Notify bit, cursor move and print screen functions arenot available)All the display elements other than thumbwheel type numeral input(However, only 1 numeral/character string input (temporary inputfield) can be displayed)Numeral/character string input (only 1 of these)Pop-upwindowfunctiontouch switchOnly Keyboard screen can be controlled.Window position can not be changed.Local window1 or local window2 can be controlled.Window position can be changed.Windowmovefunctiontouch switchNot availableAvailableAnaloguemeterNot availableAvailableHighdefinitionfont displayNot availableCharacters of 2 2 or larger scale is displayed in high-definitionfont* (excluding marks)Connectionto MitsubishiPCsNot possiblePossibleMemory linkNot possiblePossibleInstallationof systemprogramusingMemory UnitNot possible (screen data only)PossibleProgramming Console functionscreen forCS/CJ-series PCsNot possiblePossible* Usable only when ISO 8859/1 font type is selected at the Support Tool.452Appendix BCompatibility with Screen Data of Other PT ModelsDifferences between -V1 and -V2 NT31/NT31C andNT631/NT631C PTsItemForeground/backgroundrelationshipsin screendrawingNT31/NT31C and NT631/NT631C (V1 versions)DisplayForegroundBackgroundElement TypeImage/library lampsAlarm list/history framesTemporary inputCharacter string inputThumbwheel type inputNumeral inputTrend graphsBroken line graphsAnalogue meterFrames of bar graphsNumeral displaysCharacter string displaysFixed displaysLamp displaysTouch switchesImage/library dataScreen backgroundNT31/NT31C and NT631/NT631C (V2 versions)DisplayForegroundBackgroundNo displayNormal, window, and overlapping screensSystem Initializing screenDisplay history (occurrence order) screenDisplay history (frequency order) screenScreen for Programming Console functionReturn to the previous screen0:1 to 3999 :9000:9001:9002:9020:9021 to 9023:9030:9999:Element TypeImage/library lampsRecipeAlarm list/history framesTemporary inputCharacter string inputThumbwheel type inputNumeral inputTrend graphsBroken line graphsAnalogue meterFrames of bar graphsNumeral displaysCharacter string displaysFixed displaysLamp displaysTouch switchesImage/library dataScreen backgroundScreen display0:1 to 3999 :9000:9001:9002:9020:9999:No displayNormal, window, and overlapping screensSystem Initializing screenDisplay history (occurrence order) screenDisplay history (frequency order) screenScreen for programming console functionDevice Monitor function screensBrightness and contrast adjustment screenReturn to the previous screenInterlockfunctionNot availableThe interlock function can be set for individual touch switches,numeral inputs, thumbwheel inputs, character string inputs, andrecipe objects to enable/disable operation according to the status ofthe interlock bit allocated in the host.Labels(Guide characters)Fixed character strings only (1 line only)Four kinds of character strings are available:Fixed character strings (Multiple lines are possible.)ON/OFF switching character strings (Multiple lines are possible.)Numeral displays (Displays numeral memory table entries.)Character string displays (Displays character string memory tableentries.)Device Monitor functionNot availableCan be used to switch the PC’s operating mode, display/changecontents of PC words, and display the error log.Mathematical functionNot availableCan be used to automatically execute up to 256 formulas registeredin mathematical table.(Operands (results) are automatically read from (written to) numeralmemory table entries or PC words.)High-speed1:N NT LinkNot available (Only the standard 1:N NT Link is supported.)Available (Both the standard and high-speed 1:N NT Link aresupported.)Recipe functionNot availableCan be used to read/write several words of data specified usingtabular elements on the PT to/from the host.AccessibleCS/CJ-series dataareas• CIO area• CIO area• TIM area (timer PVs)• HR area• CNT area (counter PVs)• WR area (work areas)• DM area• TK area (task flags)• EM area (current bank only)• TIM area (timer PVs)• TU area (timer completion flags)• CNT area (counter PVs)• CU area (counter completion flags)• DM area• EM area (current bank and banks 0 to C)NT30/620compatiblemodeNot availableAvailable (Refer to Appendix C for details.)453Compatibility with Screen Data of Other PT ModelsAppendix BRelationship between System Program and HardwareHere, relationship between system program and hardware is described.NT21 System ProgramsThe system program indicated below is installed in the NT21 in the default state.