Диссертация (1150338), страница 16
Текст из файла (страница 16)
Layer by layer assembly of glucose oxidase and thioureaonto glassy carbon electrode: Fabrication of glucose biosensor // Electrochimica Acta. ‒2011. ‒ T. 56, № 17. ‒ C. 6097-6105.78. Sun Y., Yan F., Yang W., Sun C. Multilayered construction of glucose oxidase andsilica nanoparticles on Au electrodes based on layer-by-layer covalent attachment //Biomaterials. ‒ 2006.
‒ T. 27, № 21. ‒ C. 4042-9.79. Chen X., Yan X., Khor K. A., Tay B. K. Multilayer assembly of positively chargedpolyelectrolyte and negatively charged glucose oxidase on a 3D Nafion network fordetecting glucose // Biosens Bioelectron.
‒ 2007. ‒ T. 22, № 12. ‒ C. 3256-60.80. Gonzalez-Macia L., Smyth M. R., Killard A. J. Evaluation of a silver-basedelectrocatalyst for the determination of hydrogen peroxide formed via enzymaticoxidation // Talanta. ‒ 2012. ‒ T. 99. ‒ C. 989-96.81.
Wu B. Y., Hou S. H., Yin F., Li J., Zhao Z. X., Huang J. D., Chen Q. Amperometricglucose biosensor based on layer-by-layer assembly of multilayer films composed ofchitosan, gold nanoparticles and glucose oxidase modified Pt electrode // BiosensBioelectron. ‒ 2007. ‒ T. 22, № 6. ‒ C. 838-44.82. Zhai Y., Zhai S., Chen G., Zhang K., Yue Q., Wang L., Liu J., Jia J.
Effects ofmorphology of nanostructured ZnO on direct electrochemistry and biosensing propertiesof glucose oxidase // Journal of Electroanalytical Chemistry. ‒ 2011. ‒ T. 656, № 1-2. ‒C. 198-205.83. Zhang W., Huang Y., Dai H., Wang X., Fan C., Li G. Tuning the redox andenzymatic activity of glucose oxidase in layered organic films and its application inglucose biosensors // Anal Biochem.
‒ 2004. ‒ T. 329, № 1. ‒ C. 85-90.84. Zhao H., Ju H. Multilayer membranes for glucose biosensing via layer-by-layerassembly of multiwall carbon nanotubes and glucose oxidase // Anal Biochem. ‒ 2006.‒ T. 350, № 1. ‒ C. 138-44.85. Liu S., Ju H. Reagentless glucose biosensor based on direct electron transfer ofglucose oxidase immobilized on colloidal gold modified carbon paste electrode //Biosensors and Bioelectronics. ‒ 2003. ‒ T. 19, № 3.
‒ C. 177-183.12886. Ivnitski D., Branch B., Atanassov P., Apblett C. Glucose oxidase anode for biofuelcell based on direct electron transfer // Electrochemistry Communications. ‒ 2006. ‒ T.8, № 8. ‒ C. 1204-1210.87. Si P., Kannan P., Guo L., Son H., Kim D.-H. Highly stable and sensitive glucosebiosensor based on covalently assembled high density Au nanostructures // Biosensorsand Bioelectronics. ‒ 2011. ‒ T. 26, № 9. ‒ C. 3845-3851.88.
Lu Y., Yang M., Qu F., Shen G., Yu R. Enzyme-functionalized gold nanowires forthe fabrication of biosensors // Bioelectrochemistry. ‒ 2007. ‒ T. 71, № 2. ‒ C. 211-216.89. Wu B.-Y., Hou S.-H., Yin F., Li J., Zhao Z.-X., Huang J.-D., Chen Q.Amperometric glucose biosensor based on layer-by-layer assembly of multilayer filmscomposed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode //Biosensors and Bioelectronics. ‒ 2007.
‒ T. 22, № 6. ‒ C. 838-844.90. Ozoemena K. I., Nyokong T. Comparative electrochemistry and electrocatalyticactivities of cobalt, iron and manganese phthalocyanine complexes axially co-ordinatedto mercaptopyridine self-assembled monolayer at gold electrodes // ElectrochimicaActa. ‒ 2006. ‒ T. 51, № 13.
‒ C. 2669-2677.91. Sampath S., Lev O. Inert Metal-Modified, Composite Ceramic−Carbon,Amperometric Biosensors: Renewable, Controlled Reactive Layer // AnalyticalChemistry. ‒ 1996. ‒ T. 68, № 13. ‒ C. 2015-2021.92. Lynn M. Inorganic support intermediates: covalent coupling of enzymes oninorganic supports // Immobilized enzymes, antigens, antibodies and peptides. ‒ 1975. ‒C. 1-48.93. Schröper F., Brüggemann D., Mourzina Y., Wolfrum B., Offenhäusser A., Mayer D.Analyzing the electroactive surface of gold nanopillars by electrochemical methods forelectrode miniaturization // Electrochimica Acta.
‒ 2008. ‒ T. 53, № 21. ‒ C. 62656272.94. Kisner A., Lenk S., Mayer D., Mourzina Y., Offenhäusser A. Determination of theStability Constant of the Intermediate Complex during the Synthesis of AuNanoparticles Using Aurous Halide // The Journal of Physical Chemistry C. ‒ 2009. ‒T. 113, № 47. ‒ C. 20143-20147.12995. Halder A., Ravishankar N. Gold Nanostructures from Cube-Shaped CrystallineIntermediates // The Journal of Physical Chemistry B. ‒ 2006. ‒ T.
110, № 13. ‒ C.6595-6600.96. Halder A., Ravishankar N. Ultrafine Single-Crystalline Gold Nanowire Arrays byOriented Attachment // Advanced Materials. ‒ 2007. ‒ T. 19, № 14. ‒ C. 1854-1858.97. Love J. C., Estroff L. A., Kriebel J. K., Nuzzo R. G., Whitesides G. M. SelfAssembled Monolayers of Thiolates on Metals as a Form of Nanotechnology //Chemical Reviews. ‒ 2005. ‒ T. 105, № 4. ‒ C.
1103-1170.98. Dhara K., Ramachandran T., Nair B. G., Babu T. G. S. Au nanoparticles decoratedreduced graphene oxide for the fabrication of disposable nonenzymatic hydrogenperoxide sensor // Journal of Electroanalytical Chemistry. ‒ 2016. ‒ T. 764. ‒ C. 64-70.99. Mei H., Wu W. Q., Yu B. B., Wu H. M., Wang S.
F., Xia Q. H. Nonenzymaticelectrochemical sensor based on Fe@Pt core-shell nanoparticles for hydrogen peroxide,glucose and formaldehyde // Sensors and Actuators B-Chemical. ‒ 2016. ‒ T. 223. ‒ C.68-75.100. Wu Q., Sheng Q. L., Zheng J. B. Nonenzymatic sensing of glucose using a glassycarbon electrode modified with halloysite nanotubes heavily loaded with palladiumnanoparticles // Journal of Electroanalytical Chemistry. ‒ 2016.
‒ T. 762. ‒ C. 51-58.101. Chen S. H., Yuan R., Chai Y. Q., Hu F. X. Electrochemical sensing of hydrogenperoxide using metal nanoparticles: a review // Microchimica Acta. ‒ 2013. ‒ T. 180, №1-2. ‒ C. 15-32.102. Chen X. M., Wu G. H., Cai Z. X., Oyama M., Chen X. Advances in enzyme-freeelectrochemical sensors for hydrogen peroxide, glucose, and uric acid // MicrochimicaActa.
‒ 2014. ‒ T. 181, № 7-8. ‒ C. 689-705.103. Moozarm Nia P., Lorestani F., Meng W. P., Alias Y. A novel non-enzymaticH2O2 sensor based on polypyrrole nanofibers–silver nanoparticles decorated reducedgraphene oxide nano composites // Applied Surface Science. ‒ 2015. ‒ T. 332.
‒ C. 648656.104. Anwar N., McCormac T., Compain J. D., Mialane P., Dolbecq A., Laffir F.Surfaceimmobilisationofthesandwichtype130Na14[Fe4(Ox)4(H2O)2(SbW9O33)2]·60H2O polyoxometalate // Electrochimica Acta.‒ 2012. ‒ T. 59. ‒ C.
1-7.105. Kong X., Zhao J., Han J., Zhang D., Wei M., Duan X. Fabrication of Naphtholgreen B/layered double hydroxide nanosheets ultrathin film and its application inelectrocatalysis // Electrochimica Acta. ‒ 2011. ‒ T. 56, № 3. ‒ C. 1123-1129.106. Shao M., Han J., Shi W., Wei M., Duan X. Layer-by-layer assembly ofporphyrin/layered double hydroxide ultrathin film and its electrocatalytic behavior forH2O2 // Electrochemistry Communications.
‒ 2010. ‒ T. 12, № 8. ‒ C. 1077-1080.107. Sun Y., Bai Y., Yang W., Sun C. Controlled multilayer films of sulfonate-cappedgold nanoparticles/thionine used for construction of a reagentless bienzymatic glucosebiosensor // Electrochimica Acta. ‒ 2007. ‒ T. 52, № 25. ‒ C. 7352-7361.108. Baioni A. P., Vidotti M., Fiorito P. A., Córdoba de Torresi S. I. Copperhexacyanoferrate nanoparticles modified electrodes: A versatile tool for biosensors //Journal of Electroanalytical Chemistry.
‒ 2008. ‒ T. 622, № 2. ‒ C. 219-224.109. Miao Y., Wang H., Shao Y., Tang Z., Wang J., Lin Y. Layer-by-layer assembledhybrid film of carbon nanotubes/iron oxide nanocrystals for reagentless electrochemicaldetection of H2O2 // Sensors and Actuators B: Chemical. ‒ 2009. ‒ T. 138, № 1.
‒ C.182-188.110. Koodlur L. S. Layer-by-layer self assembly of a water-soluble phthalocyanine ongold. Application to the electrochemical determination of hydrogen peroxide //Bioelectrochemistry. ‒ 2013. ‒ T. 91. ‒ C. 21-7.111. Pillay J., Ozoemena K. I. Layer-by-layer self-assembled nanostructuredphthalocyaninatoiron(II)/SWCNT-poly(m-aminobenzenesulfonic acid) hybrid systemon gold surface: Electron transfer dynamics and amplification of H2O2 response //Electrochimica Acta. ‒ 2009.
‒ T. 54, № 22. ‒ C. 5053-5059.112. Dontsova E. A., Zeifman Y. S., Budashov I. A., Eremenko A. V., Kalnov S. L.,Kurochkin I. N. Screen-printed carbon electrode for choline based on MnO2nanoparticles and choline oxidase/polyelectrolyte layers // Sensors and Actuators B:Chemical. ‒ 2011.
‒ T. 159, № 1. ‒ C. 261-270.131113. Hornok V., Dekany I. Synthesis and stabilization of Prussian blue nanoparticlesand application for sensors // J Colloid Interface Sci. ‒ 2007. ‒ T. 309, № 1. ‒ C. 17682.114. Miao X., Hu N. pH-tunable bioelectrocatalysis based on layer-by-layer filmsassembled with TiO2 nanoparticles and poly(allylamine hydrochloride) // Journal ofElectroanalytical Chemistry. ‒ 2011.