(Move toadvanced function setting level is displayed.)H'00000001 (1): Move to initial setting/communicationssetting level is allowed. (Move toadvanced function setting level is not displayed.)H'00000002 (2): Move to initial setting/communicationssetting level is prohibited.C10002Setup change protectionH'00000000 (0): OFF (Changing of setup on Controllerdisplay is allowed.)H'00000001 (1): ON (Changing of setup on Controller display is prohibited.)C10003Set pointSP lower limit to SP upper limitC10004Alarm value 1H'FFFFF831 to H'0000270F (−1999 to 9999)C10005Upper-limit alarm 1H'FFFFF831 to H'0000270F (−1999 to 9999)C10006Lower-limit alarm 1H'FFFFF831 to H'0000270F (−1999 to 9999)C10007Alarm value 2H'FFFFF831 to H'0000270F (−1999 to 9999)C10008Upper-limit alarm 2H'FFFFF831 to H'0000270F (−1999 to 9999)C10009Lower-limit alarm 2H'FFFFF831 to H'0000270F (−1999 to 9999)C1000AAlarm value 3(See note 2.)H'FFFFF831 to H'0000270F (−1999 to 9999)C1000BUpper-limit alarmvalue 3 (See note 2.)H'FFFFF831 to H'0000270F (−1999 to 9999)C1000CLower-limit alarmvalue 3 (See note 2.)H'FFFFF831 to H'0000270F (−1999 to 9999)ProtectOperating3-3Com DataC1LevelSECTION 3 Communications Data for CompoWay/F and SYSWAYCom DataVariabletypeAddressParameter nameSetting (monitor) valueC1000DHeater burnout 1detectionH'00000000 to H'000001F4 (0.0 to 50.0)C1000ESet point 0SP lower limit to SP upper limitC1000FSet point 1SP lower limit to SP upper limitC10010Set point 2SP lower limit to SP upper limitC10011Set point 3SP lower limit to SP upper limitC10012Temperature inputshift valueH'FFFFF831 to H'0000270F (−199.9 to 999.9)C10013Upper-limit temperature input shift valueH'FFFFF831 to H'0000270F (−199.9 to 999.9)C10014Lower-limit temperature input shift valueH'FFFFF831 to H'0000270F (−199.9 to 999.9)C10015Proportional bandH'00000001 to H'0000270F (0.1 to 999.9)C10016Integral timeH'00000000 to H'00000F9F (0 to 3999)C10017Derivative timeH’00000000 to H’00000F9F (0 to 3999) (Range when RT is“OFF”)H’00000000 to H’0000270F (0.0 to 999.9) (Range whenRT is “ON”)C10018Cooling coefficientH'00000001 to H'0000270F (0.01 to 99.99)3-4LevelAdjustment3.1 Variable Area (Setting Range) ListVariabletypeAddressParameter nameSetting (monitor) value0019Dead bandH'FFFFF831 to H'0000270F(−199.9 to 999.9 for TC/Pt multi-input models)(−19.9 to 99.99 for Analog input models)C1001AManual reset valueH'00000000 to H'000003E8 (0.0 to 100.0)C1001BHysteresis (heating)H'00000001 to H'0000270F(0.1 to 999.9 for TC/Pt multi-input models)(0.01 to 99.99 for Analog input models)C1001CHysteresis (cooling)H'00000001 to H'0000270F(0.1 to 999.9 for TC/Pt multi-input models)(0.01 to 99.99 for Analog input models)C1001DHeater burnout 2detectionH'00000000 to H'000001F4 (0.0 to 50.0)C1001EHS alarm 1H'00000000 to H'000001F4 (0.0 to 50.0)C1001FHS alarm 2H'00000000 to H'000001F4 (0.0 to 50.0)C10020Soak timeH'00000001 to H'0000270F (1 to 9999)C10021Wait bandH'00000000 (0): OFFH'00000001 to H'0000270F(0.1 to 999.9 for TC/Pt multi-input models)(0.01 to 99.99 for Analog input models)C10022MV at stopStandard: H'FFFFFFCE to H'0000041A (−5.0 to 105.0)Heating and cooling: H'FFFFFBE6 to H'0000041A(−105.0 to 105.0)C10023MV at PV errorStandard: H'FFFFFFCE to H'0000041A (−5.0 to 105.0)Heating and cooling: H'FFFFFBE6 to H'0000041A(−105.0 to 105.0)AdjustmentCom DataC1LevelNote: The alarm function can also be used in Controllers without alarm output terminals.
In this case,confirm alarm occurrences via the status data.3-5Com DataSECTION 3 Communications Data for CompoWay/F and SYSWAYVariabletypeAddressC10024Manual manipulatedvariableStandard: H'FFFFFFCE to H'0000041A (−5.0 to 105.0)Heating and cooling: H'FFFFFBE6 to H'0000041A (−105.0to 105.0)ManualControlC10025SP ramp set valueH'00000000 (0): OFFH'00000001 to H'0000270F (1 to 9999)AdjustmentC10026MV upper limitStandard: MV lower limit + 0.1 to H’0000041A (MV lowerlimit + 0.1 to 105.0)Heating and cooling: H'00000000 to H'0000041A (0.0 to105.0)C10027MV lower limitStandard: H’FFFFFFCE to MV upper limit − 0.1 (−5.0 to MVupper limit − 0.1)Heating and cooling: H'FFFFFBE6 to H'00000000 (−105.0to 0.0)C10028Move protect levelH'FFFFF831 to H'0000270F (−1999 to 9999)C10029Password to move toprotect levelH'FFFFF831 to H'0000270F (−1999 to 9999)(Can only be set.
The monitor value is always H’00000000.)C1002AParameter maskenableH'00000000 (0): OFFH'00000001 (1): ONC30000Input type (TC/Ptmulti-input models)(See note.)H'00000000 (0):H'00000001 (1):H'00000002 (2):H'00000003 (3):H'00000004 (4):Parameter nameSetting (monitor) valueH'00000005 (5):H'00000006 (6):H'00000007 (7):H'00000008 (8):H'00000009 (9):H'0000000A (10):H'0000000B (11):H'0000000C (12):H'0000000D (13):H'0000000E (14):H'0000000F (15):H'00000010 (16):H'00000011 (17):H'00000012 (18):H'00000013 (19):Pt (−200 to 850°C/−300 to 1500°F)Pt (−199.9 to 500.0°C/−199.9 to 900.0°F)Pt (0.0 to 100.0°C/0.0 to 210.0°F)JPt (−199.9 to 500.0°C/−199.9 to 900.0°F)JPt (0.0 to 100.0°C/0.0 to 210.0°F)K (−200 to 1300°C/−300 to 2300°F)K (−20.0 to 500.0°C/0.0 to 900.0°F)J (−100 to 850°C/−100 to 1500°F)J (−20.0 to 400.0°C/0.0 to 750.0°F)T (−200 to 400°C/−300 to 700°F)T (−199.9 to 400.0°C/−199.9 to 700.0°F)E (0 to 600°C/0 to 1100°F)L (−100 to 850°C/−100 to 1500°F)U (−200 to 400°C/−300 to 700°F)U (−199.9 to 400.0°C/−199.9 to 700.0°F)N (−200 to 1300°C/−300 to 2300°F)R (0 to 1700°C/0 to 3000°F)S (0 to 1700°C/0 to 3000°F)B (100 to 1800°C/300 to 3200°F)Infrared temperature sensor(K 140°F/60°C)H'00000014 (20): Infrared temperature sensor(K 240°F/120°C)H'00000015 (21): Infrared temperature sensor(K 280°F/140°C)H'00000016 (22): Infrared temperature sensor(K 440°F/220°C)H'00000017 (23): 0 to 50 mV3-6LevelProtectInitial setting3.1 Variable Area (Setting Range) ListVariabletypeAddressC30000Input type (analoginput models) (Seenote.)H'00000000 (0): 4 to 20 mAH'00000001 (1): 0 to 20 mAH'00000002 (2): 1 to 5 VH'00000003 (3): 0 to 5 VH'00000004 (4): 0 to 10 VC30001Scaling upper limitScaling lower limit + 1 to H’0000270F (scaling lower limit + 1to 9,999)C30002Scaling lower limitH’FFFFF831 to Scaling upper limit − 1 (−1999 to Scalingupper limit − 1)C30003Decimal point position (TC/Pt multi-inputmodels)H'00000000 to 00000001 (0 to 1)Decimal point position (analog inputmodels)H'00000000 to 00000003 (0 to 3)Parameter nameSetting (monitor) value0004Temperature unitH'00000000 (0): °CH'00000001 (1): °FC30005SP upper limitThe range of values (without decimal point) is as follows:Temperature: SP lower limit + 1 to Input range upper limitAnalog: SP lower limit + 1 to Scaling upper limitC30006SP lower limitThe range of values (without decimal point) is as follows:Temperature: Input range lower limit to SP upper limit − 1Analog: Scaling lower limit to SP upper limit − 1C30007PID/OnOffH'00000000 (0): ON/OFFH'00000001 (1): 2 degrees of freedom PID controlC30008Standard or heatingand coolingH'00000000 (0): StandardH'00000001 (1): Heating and coolingC30009STH'00000000 (0): OFFH'00000001 (1): ONInitial settingCom DataC3LevelNote:The input type can be selected to match the connected sensor.There are two input type specifications: Thermocouple/Resistance thermometer input and Analoginput.3-7Com DataSECTION 3 Communications Data for CompoWay/F and SYSWAYVariabletypeAddressC3000AControl period (heat)H'00000000 (0): 0.5H'00000001 to H'00000063 (1 to 99)C3000BControl period (cool)H'00000000 (0): 0.5H'00000001 to H'00000063 (1 to 99)C3000CDirect/reverse operationH'00000000 (0): Reverse operationH'00000001 (1): Direct operationC3000DAlarm 1 typeH'00000000 (0):H'00000001 (1):H'00000002 (2):H'00000003 (3):H'00000004 (4):H'00000005 (5):C3000EAlarm 2 typeH'00000000 (0):H'00000001 (1):H'00000002 (2):H'00000003 (3):H'00000004 (4):H'00000005 (5):C3000FAlarm 3 type(See note 2.)Same settings as the alarm 2 type3-8Parameter nameSetting (monitor) valueAlarm function OFFUpper and lower-limit alarmUpper-limit alarmLower-limit alarmUpper and lower-limit range alarmUpper and lower-limit alarm with standbysequenceH'00000006 (6): Upper-limit alarm with standby sequenceH'00000007 (7): Lower-limit alarm with standby sequenceH'00000008 (8): Absolute-value upper-limit alarmH'00000009 (9): Absolute-value lower-limit alarmH'0000000A (10): Absolute-value upper-limit alarm withstandby sequenceH'0000000B (11): Absolute-value lower-limit alarm withstandby sequenceH'0000000C (12): LBA (Loop Burnout Alarm)Alarm function OFFUpper and lower-limit alarmUpper-limit alarmLower-limit alarmUpper and lower-limit range alarmUpper and lower-limit alarm with standbysequenceH'00000006 (6): Upper-limit alarm with standby sequenceH'00000007 (7): Lower-limit alarm with standby sequenceH'00000008 (8): Absolute-value upper-limit alarmH'00000009 (9): Absolute-value lower-limit alarmH'0000000A (10): Absolute-value upper-limit alarm withstandby sequenceH'0000000B (11): Absolute-value lower-limit alarm withstandby sequenceLevelInitial setting3.1 Variable Area (Setting Range) ListVariabletypeAddressC30010Communications unitnumber (See note 3.)H'00000000 to H'00000063 (0 to 99)C30011Communications baudrate(See note 3.)H'00000000 (0): 1.2H'00000001 (1): 2.4H'00000002 (2): 4.8H'00000003 (3): 9.6H'00000004 (4): 19.2H'00000005 (5): 38.4C30012Communications datalength(See note 3.)H'00000007 (7): 7H'00000008 (8): 8C30013Communications stopbits (See note 3.)H'00000001 (1): 1H'00000002 (2): 2C30014Communications parity (See note 3.)H'00000000 (0): NoneH'00000001 (1): EvenH'00000002 (2): OddParameter nameSetting (monitor) valueLevelCommunicationssettingconfirm alarm occurrences via the status data.3-9Com DataNote: The alarm function can also be used in Controllers without alarm output terminals.