NT21_Setup Manual (V068-E1-1) (986757), страница 34
Текст из файла (страница 34)
9Input:Pressure-sensitive type7 vertically)9 mmOperating force: 1 N minimumLife expectancy: One million operations minimumExternal Interface SpecificationsItemSerial communicationExpansion interfaceSerial ports A and BSpecificationConforms to EIA RS-232CD-SUB 9-pin connector (female)+5 V output at pin No.
6 (Total output 150 mA max. from ports A and B)Dedicated connectorNote When using the +5 V output of pin No. 6, check that the total current required by the devices connected toports A and B is less than 150 mA. The NT21 supplies +5 V "5% (150 mA max.) to pin 6 of these ports.188Appendix ASpecificationsProgramming EnvironmentItemSpecificationProgramming SystemProgramming Support SoftwareProgramming DeviceProgramming Support Software: NT-series Support Tool for Windows (Ver. 5), by OMRONSpecial FeaturesItemSpecificationsBuzzerThree kinds of buzzer sound (continuous, short intermittent, and long intermittent)Sounds:On reception of a command from the host, display of a screen with abuzzer setting, or display of an error screen such as for a receive error.Stops:On reception of a command from the host, or display of a screen withno buzzer setting.Setting:Set “ON” for “Buzzer Sound” in the memory switch menu, or set“ERROR ON” for the buzzer to sound only when an error occurs.The buzzer sounds three times in response to prohibited input.Touch switch input soundTouch switchesInput sound: Sounding for 0.2 secondsSetting:Set “ON” for “Key Press Sound” in the memory switch menu.Maintenance function- Memory switch setting- Self-test functions, such as for the memory and external interface- Setting condition confirmation function- Communication check function- Initialization of internal memory data- Display of display/alarm history data- Registered data test display functionBattery backup (optional)- Backup of numeral/character string memory table data in the NT21- Backup of display/alarm history data- Backup of recipe dataBattery life:5 years (at 25_C)When voltage becomes low: RUN Indicator lights in orange or redThe communication flag to the PC (BAT LOW) isturned ON (1).Resume function(Operates only when theoptional battery is installed.)Retains the contents of the numeral and character string memory tables (i.e., theyare not initialized) when the NT21 is turned ON or the operation mode is changed.Setting:Set “ON” for “Resume Function” in the memory switch menu.Calendar and clock function- Displays the date and time read from the PC.- Display the date and time with the “Calendar Check” operation.Programming Console functionExecutes functions equivalent to those of a C200H-PRO27-E Programming Consolefor CPM1, CPM1A, CPM2A, CPM2C, CQM1 (-EV1 only), CQM1H,C200HX/HG/HE(-Z)E, and SRM1 (C02-V2 only) PCs.Executes functions as a Programming Console for CS/CJ-series PC.Mathematical functionTransmissionfunctionsUp to 256 calculation expressions can be registered along with the screen data.
Thecalculation function reads the required data from the numeral memory table or hostwords, executes the registered calculations, and writes the results.Arithmetic operators, logic operators, bit operators, and comparative operators canbe used.System programtransmissionDownloads the system program from the system installer.Downloads/Upload the system program with a Memory Unit.Screen datatransmission- Function for downloading screen data to and uploading screen data from theNT Support Tool- Function for transmitting screen data to and from the Memory Unit.History datauploadingFunction for uploading display/alarm history data from PT.189Appendix ASpecificationsCommunications SpecificationsSpecifications for Host Link CommunicationsItemSpecificationCommunications standardEIA RS-232CCommunications settingsStart-stop synchronizationBaud rate:Data length:Stop bits:Parity:Connector9-pin D-SUB connectors (female) (serial ports A and B)Number of Units connected1:1Transmission distanceMax.
15 m*9,600 or 19,200 bps7 bits2 bitsEvenCommunications protocolC-series SYSWAY (1:N)* When using an NT-AL001 or NS-AL002 Link Adapter, the specifications are as follows:• RS-232C cable: Max. 2 m (Not required with the NS-AL002)• RS-422A cable: Total length 500 m max.Specifications for 1:1 NT Link CommunicationsItemSpecificationCommunications standardEIA RS-232CConnector9-pin D-SUB connectors (female) (serial ports A and B)Number of Units connected1:1Transmission distanceMax. 15 m** When using an NT-AL001 or NS-AL002 Link Adapter, the specifications are as follows:• RS-232C cable: Max. 2 m (Not required with the NS-AL002)• RS-422A cable: Total length 500 m max.Specifications for 1:N NT Link CommunicationsItemSpecificationCommunications standardEIA RS-232CConnector9-pin D-SUB connectors (female) (serial ports A and B)Number of Units connected1:1 to 8Transmission distanceMax.
15 m** NT-AL001 or NS-AL002 Link Adapters are required to connect two or more PTs. When using Link Adapters, thespecifications are as follows:• RS-232C cable:Max. 2 m (Not required with the NS-AL002)• RS-422A/485 cable: Total length 500 m max.190Appendix ASpecificationsSpecifications for High-speed 1:N NT Link CommunicationsItemSpecificationCommunications standardEIA RS-232CConnector9-pin D-SUB connectors (female) (serial ports A and B)Number of Units connected1:1 to 8Transmission distanceMax. 15 m** NT-AL001 or NS-AL002 Link Adapters are required to connect two or more PTs.
When using Link Adapters, thespecifications are as follows:• RS-232C cable:Max. 2 m (Not required with the NS-AL002)• RS-422A/485 cable: Total length 500 m max.Specifications for Memory Link CommunicationsItemSpecificationCommunications standardEIA RS-232CCommunications settingsStart-stop synchronizationBaud rate:Data length:Stop bits:Parity:Flow control:Response:Connector9-pin D-SUB connectors (female) (serial ports A and B)Number of Units connected1:1Transmission distanceMax. 15 m*1,200, 2,400, 4,800, 9,600, 19,200, or 38,400 bps7, 8 bits1, 2 bitsNone, even, oddNone, RS/CS, XON/XOFFPresence/absenceCommunications protocolMemory link* When using NT-AL001 or NS-AL002 Link Adapter, specifications are as follows:• RS-232C: Max.
2 m (Not required with the NS-AL002)• RS-422A: Max. total length 500 mSpecifications for Bar Code Reader CommunicationsItemSpecificationCommunications standardEIA RS-232CCommunications settingsStart-stop synchronizationBaud rate:Data length:Stop bits:Parity:Flow control:Connector9-pin D-SUB connector (female) (serial port A)Number of Units connected1:1Transmission distanceMax. 15 mCommunications protocolNon-protocol modeData format[STX]4,800, 9,600, or 19,200 bps7, 8 bits1, 2 bitsNone, even, oddRS/CSData (0 to 40 bytes)[ETX]191Appendix BExternal Dimensions and MountingDimensionsPTs53.5 (2.11)178 (7.01)100 (3.94)122 (4.80)110 (4.33)Mounting panelMounting fixture15.5(0.61)4.5(0.18)142 (5.59)190 (7.48)Units: mm (inch)193Appendix BExternal Dimensions and Mounting Dimensions28 (1.10)51.1 (2.01)28 (1.10)Cable Connection Dimensions39.5 (1.56)45(1.77)19.5(0.77)58.3 (2.30)72.6 (2.86)52.5 (2.07)19.5(0.77)28 (1.10)28 (1.10)Units: mm (inch)39.5(1.56)52.5 (2.07)43.6 (1.72)72.6 (2.86)Units: mm (inch)194Appendix CTransporting and Storing the NT21• When transporting the NT21, use the packaging intended for it.• When storing the NT21, observe the following conditions.Storage ambient temperature: –20 to 70_CStorage ambient humidity:0 to 40_C:85%40 to 50_C:55%50 to 70_C:23%195Appendix DMaking the CableThe procedure for making up the cable is described below.Also refer to this procedure for making a connecting cable for use with RS-422A/485 type connections.Cable PreparationThe preparation of the cable differs according to whether or not the shielding wire is to be connected to the FG.Cable with Shield Connected to FG1, 2, 3...1.
Cut the cable to the required length.2. Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage theshielding underneath.3. Cut back the shielding wire with scissors.4. Use wire strippers to strip the insulation from each wire.5. Fold back the shielding wire.6. Wrap aluminum foil tape around the folded-back shielding wire.(1)(2)40 (1.57) (RS-232C)25 (0.98) (RS-422A)(3)10(0.39)(4)5(0.19)(5)(6)Units: mm (inch)Aluminum foil tapeCable with Shield Not Connected to FG1, 2, 3...1. Cut the cable to the required length.2. Remove the external vinyl insulation from the cable with a razor blade. Take care not to damage theshielding underneath.3.
Cut back the shielding wire with scissors.4. Use wire strippers to strip the insulation from each wire.197Appendix DMaking the Cable5. Wrap vinyl tape over the cut off end of the shielding wire.(1)(2)40 (1.57) (RS-232C)25 (0.98) (RS-422A)(3)(4)5(0.19)(5)Units: mm (inch)Vinyl tapeSoldering1, 2, 3...1. Slide heat-shrink tube over each wire.2. Pre-solder each wire and connector terminal.3. Solder each wire to each connector terminal.1 mmSoldering ironHeat-shrink tube(F, 1.5 mm dia., ȏ = 10 mm)4.