Speed(for host link only)FunctionSets the baud rate for communications with the host.Setting Options9,600 bps/19,200 bpsPagePage127Communication Condition Settings for the 1:1 NT Link MethodNo further communication conditions need to be set.Communication Conditions Settings for the 1:N NT Link MethodSetting ItemFunctionSetting OptionsUnit No.(for 1:N NT Link only)Set the unit number of the NT21.0 to 7Comm. SpeedSets the baud rate for communications with the host.Standard orhigh-speedPagePage1299125SectionSetting Conditions for Communications with Host by Using Memory Switches6-7Setting the Conditions for Communications with the Memory Link MethodSetting ItemPossible Combinationsof CommunicationMethod SettingsFunctionSetting OptionsData bitsSet the data bits length.7, 8 bitsStop bitsSet the stop bits length.1, 2 bitsParitySet the parity.None, even,oddComm.
SpeedSet the baud rate for communica- 1200, 2400,tions with the host.4800, 9600,19200, 38400bpsFlow controlSet the flow control and its method.None, RS/CS,XON/XOFFResponseSet whether the response is carried out for normal process ofcommunication command or not.Yes, NoPagePageg132The combinations of communication methods that can be set with the NT21 areindicated in the table below.
Combinations other than these listed below cannotbe set.NoneHost Link1:1 NT Link1:N NT LinkBar-codereaderMemoryLinkNoneffffffHost Linkff1:1 NT Linkff1:N NT Link(Standard orhigh-speed)ffMemory LinkffPort APort Bf: Possible combination: Impossible combinationCombinations other than those indicated above cannot be set.Reference: When using serial port B for communication with the host, and serial port A for thetransmission of screen data from the NT Support Tool, set the settings of serialport A to None.126Setting Conditions for Communications with Host by Using Memory SwitchesSection6-76-7-2 Setting the Host Link MethodSet the communication conditions for the host link method at serial port A or serial port B by following the menu operations from the Maintenance Mode Menu asshown below.Select Memory Switch.Display the fourth memory switch screen bypressing the [↓] (next screen) or [↑] (previous screen) touch switch.Press the touch switch corresponding to theport at which the host link method is to be set(Comm.
A Method or Comm. B Method) todisplay the setting option Host Link.The communications method setting on theright will change each time that the touchswitch is pressed.127Setting Conditions for Communications with Host by Using Memory SwitchesSection6-7Press the Set touch switch to the right of theport at which the setting has been made.In this example, serial port A is used.Press the Comm. Speed touch switch to display the baud rate to be set.The setting option changes each time thetouch switch is pressed.In this example, serial port A is used.Press Quit.The baud rate is set.• To quit the baud rate setting screen without setting the baud rate, press theAbort touch switch. The NT21 returns to the memory switch setting screen(4/4) and the previous baud rate remains in effect.On completion of baud rate setting, the NT21 returns to the memory switch setting screen (4/4).To set other memory switches, select the relevant screen using the [ ] (nextscreen) or [ ] (previous screen) touch switch, then make the setting.• To confirm the settings and quit the memory switch setting screen, press theQuit touch switch.
The settings made last will be set and the NT21 will return tothe MAINTENANCE MODE MENU screen.If the combination of settings for serial port A and serial port B is not allowed, anerror message (indicating that the protocol settings are incorrect) will be displayed when the Quit touch switch is pressed. In this case, correct the settingsto a combination that is allowed.• To quit the memory switch setting screen without confirming the settings, pressthe Abort touch switch. The NT21 will return to the MAINTENANCE MODEMENU screen with the previous settings still in effect.128Setting Conditions for Communications with Host by Using Memory SwitchesSection6-76-7-3 Setting the 1:1 NT Link MethodSet the communication conditions for the 1:1 NT Link method at serial port A orserial port B by following the menu operations from the Maintenance ModeMenu as shown below.Select Memory Switch.Display the fourth memory switch screen bypressing the [↓] (next screen) or [↑] (previousscreen) touch switch.Press the touch switch corresponding to theport at which the 1:1 NT Link method is to beset (Comm.
A Method or Comm. B Method) todisplay the setting option NT Link (1:1).The communications method setting on theright will change each time that the touchswitch is pressed.To set other memory switches, select the relevant screen using the [ ] (nextscreen) or [ ] (previous screen) touch switch, then make the setting.• To confirm the settings and quit the memory switch setting screen, press theQuit touch switch. The settings made last will be set and the NT21 will return tothe MAINTENANCE MODE MENU screen.If the combination of settings for serial port A and serial port B is not allowed, anerror message (indicating that the protocol settings are incorrect) will be displayed when the Quit touch switch is pressed.
In this case, correct the settingsto a combination that is allowed.• To quit the memory switch setting screen without confirming the settings, pressthe Abort touch switch. The NT21 will return to the MAINTENANCE MODEMENU screen with the previous settings still in effect.6-7-4 Setting the 1:N NT Link Method (Standard/High-speed)Set the communication conditions for the 1:N NT Link method at serial port A orserial port B by following the menu operations from the Maintenance ModeMenu as shown below.129Setting Conditions for Communications with Host by Using Memory SwitchesSection6-7The baud rate determines whether the 1:N NT Link is standard or high-speed.Standard:Standard 1:N NT LinkHigh-speed:High-speed 1:N NT LinkSelect Memory Switch.Display the fourth memory switch screen bypressing the [↓] (next screen) or [↑] (previousscreen) touch switch.Press the touch switch corresponding to theport at which the 1:N NT Link method (standard or high-speed) is to be set (Comm.
AMethod or Comm. B Method) to display theNT Link (1:N) setting option.The communications method setting on theright will change each time that the touchswitch is pressed. In this example, serial portA is used.130Setting Conditions for Communications with Host by Using Memory SwitchesSection6-7Press the Set touch switch to the right of theport at which the setting has been made.In this example, serial port A is used.Press the Unit No. touch switch to displaythe unit number to be set. Press the Comm.Speed touch switch to display the baud rate,standard or 115.2-kbps high-speed.
(TheComm. Speed setting determines whichmethod of 1:N NT Link is used.)The communications setting on the right willchange each time that the touch switch ispressed. In this example, serial port A isused for a standard 1:N NT Link.Press Quit.The unit number and baud rate are set.• To quit the unit number/baud rate setting screen without confirming the unitnumber/baud rate settings, press the Abort touch switch. The NT21 will returnto the memory switch setting screen (4/4) with the previous settings still in effect.Reference: Unit numbers are numbers assigned to each PT when multiple PTs are connected to one host, so that the host can identify the individual PTs. The unit numbers that can be set differ according to the host model, as follows.S C200HE(-ZE):Unit numbers 0 to 3 (maximum of 4 PTs per host port)S C200HG(-ZE), C200HX(-ZE), CS1G/H(-H), CJ1G, CQM1H:Unit numbers 0 to 7 (maximum of 8 PTs per host port)When making the settings, make sure there is no duplication of unit numbersamong PTs.On completion of unit number/baud rate setting the NT21 returns to the memoryswitch setting screen (4/4).To set other memory switches, select the relevant screen using the [ ] (nextscreen) or [ ] (previous screen) touch switch, then make the setting.• To confirm the settings and quit the memory switch setting screen, press theQuit touch switch.
The settings made last will be set and the NT21 will return tothe MAINTENANCE MODE MENU screen.If the combination of settings for serial port A and serial port B is not allowed, an131Setting Conditions for Communications with Host by Using Memory SwitchesSection6-7error message (indicating that the protocol settings are incorrect) will be displayed when the Quit touch switch is pressed.
In this case, correct the settingsto a combination that is allowed.• To quit the memory switch setting screen without confirming the settings, pressthe Abort touch switch. The NT21 will return to the MAINTENANCE MODEMENU screen with the previous settings still in effect.6-7-5 Setting the Memory Link MethodSet the communication conditions for the host link method at serial port A or serial port B by following the menu operations from the Maintenance Mode Menu asshown below. Check the communication settings of the host to be used.Select Memory Switch.Display the fourth memory switch screen bypressing the [↓] (next screen) or [↑] (previousscreen) touch switch.Press the touch switch corresponding to theport at which the memory link method is to beset (Comm. A Method or Comm. B Method) todisplay the setting option Memory Link.The communications setting on the right willchange each time that the touch switch ispressed.In this example, serial port A is used.Press the Set touch switch to the right of theport at which the setting has been made.In this example, serial port A is used.132SectionStarting Operation6-8Display the data bits to be set (7 bits or 8 bits)by pressing the Data Bit Length touch switch.Display the stop bits to be set (1 bit or 2 bits)by pressing the Stop Bit Length touch switch.Display the parity to be set (None, even, odd)by pressing the Parity Bit touch switch.Display the baud rate to be set (1200, 2400,4800, 9600, 19200, 38400 bps.) by pressingthe Comm.
Speed touch switch.Display the condition of the flow control to beset (None, RS/CS, XON/XOFF) by pressingFlow Control touch switch.Display presence or absence of the responseby pressing the Response touch switch.The setting option changes each time thetouch switch is pressed.In this example, serial port A is used.Press the Quit touch switch.• To quit the baud rate setting screen without setting the baud rate, press theAbort touch switch.
The NT21 returns to the memory switch setting screen(4/4) and the previous baud rate remains in effect.On completion of baud rate setting, the NT21 returns to the memory switch setting screen (4/4).To set other memory switches, select the relevant screen using the [ ] (nextscreen) or [ ] (previous screen) touch switch, then make the setting.• To confirm the settings and quit the memory switch setting screen, press theQuit touch switch.