Диссертация (1154712), страница 17
Текст из файла (страница 17)
Biomed. Mater. Res.-2002.- 63(6).-Р. 765–771.113.Klinge U., Klosterhalfen B. Modified classification of surgical meshes forhernia repair based on the analyses of 1,000 explanted meshes //Hernia.2012.- 16(3).-Р.251–258.114.Klinge U., Klosterhalfen B., Birkenhauer V., Junge K., Conze J., SchumpelickV. Impact of polymer pore size on the interface scar formation in a rat model// J. Surg. Res.-2002.-103 (2).-Р.208-214.115.Klinge U., Klosterhalfen B., Conze J. et al. Modified mesh for hernia repairthat is adapted to the physiology of the abdominal wall // Eur J Surg.
- 1998.164 (12).- Р.951-960.116.Klinge U., Klosterhalfen B., Ottinger A.P., Junge K., Schumpelick V. PVDFas a new polymer for the construction of surgical meshes // Biomaterials.2002.- 23(16).-Р. 3487–3493.117.Klosterhalfen B., Klinge U. Retrieval study at 623 human mesh explants madeof polypropylene impact of mesh class and indication forms removal on tissuereaction // J Biomed Mater ResB Appl Biomater.-2013.-101.-Р.
1393-1399.118.Klosterhalfen В., Junge К., Klinge U. The lightweight and large porous meshconcept for hernia repair // Exp. Rev. Med. Dev.-2005.-2 (1).-Р.103- 117.107119.Koch A., Bringman S., Myrelid P., Smeds S., Kald A. Randomized clinicaltrial of groin hernia repair with titanium-coated lightweight mesh comparedwith standard polypropylene mesh// Br J Surg.-2008.- 95(10).-Р.1226–1231.120.Köckerling F., Schug-Pass C.
What do we know about titanizedpolypropylene meshes? An evidence-based review of the literature //Hernia.2014.-18.- Р.445-457.121.Krishnan A., Cha P., Liu Y.H. et al. Interfacial energetics of blood plasmaand serum adsorption to a hydrophobic self-assembled monolayer surface //Biomaterials.- 2006.-27 (17).-Р.3187-3194.122.Kyriakides T.R., Bornstein P. Matricellular proteins as modulators of woundhealing and the foreign body response // Thromb Haemost.-2003.-90(6).Р.986–92.123.Lambris J.D., Ekdahl K.N., Ricklin D., Nilsson B. Immune Responses toBiosurfaces .- Switzerland.-Springer.-2015.-p.93124.Lauwers P., Bracke B., Hubens G., Vaneerdeweg W.
Unusual complicationsof preperitoneal mesh implantation in the treatment of inguinal hernia // ActaChir. Belg. – 2003. – Vol. 103. – P. 513–516.125.Le N.T., Xue M., Castelnoble L.A., Jackson C.J. The dual personalities ofmatrix metalloproteinases in inflammation // Front Biosci.-2007.-12.-Р.1475–1487.126.LeBlanc K.A., Booth W.V., Whitaker J.M., et al. In vivo study of meshesimplanted over the inguinal ring and external iliac vessels in un castrated pigs// Surg Endosc.-1998.-12.-Р.247–251.127.Leischmajer R., Perlish J.S., Burgeson R.E., Shaikh-Bahai F.,Timpl R. TypeI and type III collagen interactions during fibrillogenesis // Ann N Y AcadSci. -1990.-580.-Р.161–175.128.Luijendijk R.W., Hop M.P., van den Tol M.P.
A comparison of suture repairwith mesh repair for incisional hernia// Engl. J. Med. - 2000. - Vol. 343, №6.- P. 392-400.129.Luttikhuizen D.T., Harmsen M.C., Van Luyn M.J. Cellular and molecular108dynamics in the foreign body reaction // Tissue Eng.- 2006.-12(7).-Р.1955–1970.130.Ma P.X. Biomimetic materials for tissue engineering //AdvDrug Deliv Rev.2008.-60.- Р.184–198.131.Maarek J.M., Guidoin R., Aubin M., Prud’homme R.E. Molecular weightcharacterization of virgin and explanted polyester arterial prostheses // JBiomed Mater Res.-1984.-18.-Р.881–894.132.Maciel L.C., Glina S., Palma P.C., et al. Histopathological alterations of thevas deferens in rats exposed to polypropylene mesh //BJU Int.- 2007.-100.Р.187–90.133.Marmon L.M., Vinocur C.D., Standiford S.B., Wagner C.W., Dunn J.M.,Weintraub W.H.
Evaluation of absorbable polyglycolic acid mesh as a woundsupport // J. Pediatr. Surg.- 1985 .-20(6).-Р.737–742134.Mary C., Marois Y., King M.W. et al. Comparison of the in vivo behavior ofpolyvinylidene fluoride and polypropylene sutures used in vascular surgery //ASAIO J.-1998.- 44 (3).-Р.199-206.135.Morais J.M., Papadimitrakopoulos F., Burgess D.J.
Biomaterials/tissueinteractions: possible solutions to overcome foreign body response // AAPSJ.- 2010.-12(2).-Р.188–96.136.Mühl T., Binnebösel M., Klinge U., Goedderz T. New objective measurementto characterize the porosity of textile implants // J Biomed Mater Res B ApplBiomater.- 2008.-84.-Р.176-183.137.Muno D., Kominami E., Mizuochi T. Generation of both MHC class I- andclass II-restricted antigenic peptides from exogenously added ovalbumin inmurine phagosomes // FEBS Lett.-2000.- 478 (1–2).-Р.178–182.138.Namdari S., Melnic C., Huffman G.R.
Foreign body reaction to acellulardermal matrix allograftin biologic glenoid resurfacing // Clin Orthop RelatRes.-2013.-471(8).-Р.2455–2458.139.Novitsky Y.W., Cristiano J.A., Harrell A.G., Newcomb W., Norton J.H.,Kercher K.W., Heniford B.T. Immunohistochemical analysis of host reaction109to heavyweight-, reduced-weight-, and expanded polytetrafluoroethylene(ePTFE)-basedmeshesaftershort-andlong-termintraabdominalimplantations // SurgEndosc.-2008.- 22.-Р.1070-1076.140.O’Dwyer P.J., Kingsnorth A.N., Molloy R.G., Small P.K., Lammers B.,Horeyseck G. Randomized clinical trial assessing impact of a lightweight orheavyweight mesh on chronic pain after inguinal hernia repair // Br. J. Surg2005.- 92(2).-Р.166–170.141.Ott V., Groebli Y., Schneider R. Late intestinal fistula formation afterincisional hernia using intraperitoneal mesh // Hernia.-2005.-9 (1).- Р.103104.142.Parker D.M.
et al. Porcine dermal collagen (Permacol) for abdominal wallreconstruction // Currative Surgery. –2006.–Vol. 63. –P.255-258.143.Pascual G., Rodrıguez M., Sotomayor S., Perez-Kohler B., Bellon J.M. (2012)Inflammatory reaction and neotissue maturation in the early host tissueincorporation of polypropylene prostheses // Hernia.-2012.-16(6).-Р. 697–707.144.Peiper C., Junge K., Klinge U., et al. Is there a risk of infertility after inguinalmesh repair? Experimental studies in the pig and the rabbit // Hernia.- 2006.10.-Р.7–12.145.Peiper C., Junge K., Klinge U., et al.
The influence of inguinal mesh repair onthe spermatic cord: a pilot study in the rabbit // J Invest Surg.- 2005.-18.Р.273–278.146.Pereira-Lucena C.G., Artigiani-Neto A., Lopes-Filho G.J., Frazao C.V.G.,Goldenberg A., Matos D., Linhares M.M. Experimental study comparingmeshes made of polypropylene, poly- propylene, polyglactin andpolypropylene titanium: in fammatory cytokines, histological changes andmorphometric analysis of collagen // Hernia.-2010.-14.-Р299–304.147.Pruett S.B. Stress and the immune system // Pathophysiology.- 2003.- 9 (3).Р.133–153.110148.Ratner B.D.
A pore way to heal and regenerate: 21st century thinking onbiocompatibility // Regen Biomater.-2016.- Jun.-3(2).-Р.107-110.149.Read R.C. Milestones in the history of hernia surgery: Prosthetic repair //Hernia.-2004.-8.-Р.8–14.150.Rennert R.C., Rustad K., Levi K., et al. A histological and mechanicalanalysis of the cardiac lead-tissue interface: Implications for lead extraction //Acta Biomater.-2014.-10.-Р.2200–2208.151.Ridgway P.F., Shah J., Darzi A.W. Male genital tract injuries aftercontemporary inguinal hernia repair // BJU Int.-2002.-90.-Р.272– 276.152.Riepe G., Loos J., Imig H.
et al. Long-term in vivo alterations of polyestervascular grafts in humans // Eur J Vasc Endovasc Surg.-1997.-13 (6).-Р. 540548.153.Robinson T.N., Clarke J.H., Schoen J., Walsh M.D. Major mesh relatedcomplications following hernia repair // Surg Endosc.-2005.-19.-Р.1556–1560.154.Rosch R., Junge K., Schachtrupp A., et al. Mesh implants in hernia repair.Inflammatory cell response in a rat model // Eur Surg Res.-2003.-35(3).Р.161-166.155.Rosch R., Lynen-Jansen P., Junge K.
et al. Biomaterial-dependent MMP-2expression in fibroblasts from patients with recurrent incisional hernias //Hernia. – 2006. – 10 (2). – P. 125-130.156.Safferling K., Sutterlin T., Westphal K., Ernst C., Breuhahn K., James M., etal. Wound healing revised: a novel reepithelialization mechanism revealed byin vitro and in silico models // J Cell Biol.-2013.-203(4).-Р. 691–709.157.Scheidbach H., Tamme C., Tannapfel A., et al.
In vivostudies comparing thebiocompatibility of various polypropylene meshes and their handlingpropertiesduring endoscopic total extraperitoneal (TEP) patchplasty: anexperimental study in pigs // Surg Endosc.-2004.-18.-Р.211–220.158.Scheidbach H., Tannapfel A., Schmidt U., Lippert H, Köckerling F. Influenceof titanium coating on the biocompatibility of a heavyweight polypropylene111mesh: an animal experimental model // Eur Surg Res.-2004.-36(5).-Р.313–317.159.Schlosser M., Wilhelm L., Urban G., Ziegler B., Ziegler M., Zippel R.Immunogenicity of polymeric implants: long-term antibody response againstpolyester (Dacron) following the implantation of vascular prostheses intoLEW.1A rats // J Biomed Mater Res.-2002.-61(3).-Р.450-457.160.Schlosser M., Ziegler B., Abel P., Fischer U., Ziegler M.
Implantation of nontoxic materials from glucose sensors: Evidence for specific antibodiesdetected by ELISA // Horm Metab Res.-1994.-26.-Р.534–537.161.Schmidt S., Haase G., Csomor E., Lutticken R., Peltroche-Llacsahuanga H.Inhibitor of complement, compstatin, prevents polymer-mediated Mac-1 upregulation of human neutrophils independent of biomaterial type tested // JBiomed Mater Res A.-2003.-66(3).-Р.491–499.162.Schopf S., von Ahnen T., von Ahnen M. et al.
(2011) Chronic pain afterlaparoscopic transabdominal preperitoneal hernia repair: a randomizedcomparison of light and extralight titanized polypropylene mesh // World JSurg.-2011.-35(2).-Р.302–310.163.Schug-Pass C., Tamme C., Tannapfel A., Köckerling F.A. Lightweightpolypropylene mesh (TiMesh) for laparoscopic intraperitoneal repair ofabdominal wall hernias: comparison of biocompatibility with the DualMeshin an experimental study using the porcine model // Surg Endosc.- 2006.20(3).-Р.
402-409.164.Schumpelick V., Klinge V. Prosthetic implants for hernia repair // Br. J. Surg.– 2003. – Vol. 90. – P. 1457- 1458.165.Schumpelick V., Nhyus L.M. Meshes: Benefits and Risks.-Berlin.- Springer.2004.-Р.198–206.166.Seker D., Kulacoglu H. Long-term complications of mesh repairs forabdominal-wall hernias // J Long Term Eff Med Implants.-2011.-21 (3).-Р.205-218.112167.Shankaran V., Weber D.J., Reed R.L., Luchette F.A. A review of availableprosthetics for ventral hernia repair // AnnSurg.-2011.-253.-Р.16–26.168.Shin D., Lipshultz L.I., Goldstein M., et al. Herniorrhaphy withpolypropylene mesh causing inguinal vasal obstruction: a preventable causeof obstructive azoospermia // Ann Surg.-2005.-241.-Р.553– 558.169.Smart N.J., Marshall M., Daniels I.R.
Biological meshes: A review of theiruse in abdominal wall hernia repairs // Surg J R Coll Surg E.-2012.-10.-Р.159–171.170.Stadelmann W.K., Digenis A.G.,Tobin G.R. Physiology and healingdynamics of chronic cutaneous wounds //Аmer. J. Surg. – 1998. – Vol. 176,N 2. – P.