Диссертация (1145462), страница 23
Текст из файла (страница 23)
2007. V. 72. P. 774-779.26. Pioggia G., Di Francesco F., Ferro M., Sorrentino F., Salvo P., Ahluwalia A.Characterization of a carbon nanotube polymer composite sensor for an impedimetricelectronic tongue // Microchim. Acta. 2008. V. 163. P. 57-62.27. Cabral, F.P.A., Bergamo, B.B., Dantas, C.A.R., Riul, A., Giacometti, J.A.Impedance e-tongue instrument for rapid liquid assessment // Rev. Scientific Instrum.2009. V. 80 (2).
P. 026107.28. Pioggia G. , Di Francesco F. , Marchetti A. , Ferro M. , Ahluwalia A. A compositesensor array impedentiometric electronic tongue: Part I. Characterization.// Biosens.Bioelectron. 2007. V. 22. P. 2618-2623.29. Pioggia G., Di Francesco F. , Marchetti A. , Ferro M. , Leardi R. , Ahluwalia A. Acomposite sensor array impedentiometric electronic tongue: Part II. Discrimination ofbasic tastes.// Biosens. Bioelectron. 2007.
V. 22. P. 2624-2628.30. Riul Jr A. , Malmegrim R. R. , Fonseca F. J. ,Mattoso L. H. C. An artificial tastesensor based on conducting polymers.// Biosens. Bioelectron. 2003. V. 18 (11). P. 13651369.15831. Riul Jr A. , De Sousa H. C. , Malmegrim R. R. , Dos Santos Jr D. S. , Carvalho A. C.P. L. F. , Fonseca F. J. , Oliveira Jr O.
N. , Mattoso L. H. C. Wine classification by tastesensors made from ultra-thin films and using neural networks.// Sens. Actuat. B. 2004.V. 98. P. 77-82.32. Olivati C. A. , Riul Jr A. , Balogh D. T. , Oliveira Jr O. N. , Ferreira M. Detection ofphenolic compounds using impedance spectroscopy measurements. // Bioproc. Biosyst.Engineer. 2009. V. 32(1).
P. 41-46.33. Cabral F. P. A. , Bergamo B. B. , Dantas C. A. R. , Riul A. , Giacometti J. A.Impedance e-tongue instrument for rapid liquid assessment.// Rev. Scient. Instrum.2009. V. 80.P. 026107.34. Lange U., Roznyatovskaya N. V. , Mirsky V. M. Conducting polymers in chemicalsensors and arrays.// Anal. Chim. Acta. 2008. V. 614. P. 1–26.35. Cortina-Puig M. , Muñoz-Berbel X.
, Alonso-Lomillo M. A., Muñoz-Pascual F. J. ,del Valle M. EIS multianalyte sensing with an automated SIA system—An electronictongue employing the impedimetric signal.// Talanta. 2007. V. 72. P. 774-779.36. Tahara Y., Toko K. Electronic Tongues–A Review // IEEE Sensors Journal. 2013.V.13(8). P.
3001-3011.37. http://www.alpha-mos.com/analytical-instruments/astree-electronic-tongue.php38. Johnson R.D., Bachas L.G. Ionophore-based ion-selective potentiometric andoptical sensors // Anal. Bioanal. Chem. 2003. V. 376. P. 328–341.39. Bobacka J., Ivaska A., Lewenstam A. Potentiometric Ion Sensors // Chem.
Rev.2008. V. 108. P. 329-351.40. Rydberg J., Cox M., Musikas C., Choppin G.R., Solvent Extraction Principles andPractices Second Edition.- New York: Marcel Dekker Inc, 2004. - 480 pages.41. Ross J. W. Calcium-Selective Electrode with Liquid Ion Exchanger.// Science NewSeries. 1967. V. 156. P. 1378-1379.42.
Eyal E., Rechnitz G. A. Mechanistic studies on the valinomycin-based potassiumelectrode.// Anal. Chem. 1971. V. 43. P. 1090-1093.43. James H. J., Carmack G. P., Freiser H. Role of Solvent Extraction Parameters inLiquid Membrane Ion Selective Electrodes.// Anal. Chem. 1972. V. 44. P. 853-855.15944. Eisenman G., Ion Selective Electrodes. Special Publications 314.- Washington DC:National Bureau of Standards, 1969.45. Cha G. S., Liu D., Meyerhoff M. E., Cantor H.
C., Midgley A. R., Goldberg H. D.,Brown R. B. Electrochemical performance, biocompatibility, and adhesion of newpolymer matrixes for solid-state ion sensors.// Anal. Chem.1991. V. 63. P. 1666–1672.46. Malinowska E., Oklejas V., Hower R.W., Brown R.B., Meyerhoff M.E. Enhancedelectrochemical performance of solid-state ion sensors based on silicone rubbermembranes.// Sens. Actuat. B. 1996.
V. 33. P. 161- 167.47. Singh A.K., Bhattacharjee G. Polystyrene membranes for ion-selective electrodes.//Electroanal. 1997. V. 9. P. 1005–1008.48. Simon M. A., Kusy R. P. The molecular, physical and mechanical properties of PVCplasticized membranes.// Polymer. 1993. V. 34. P. 5106-5110.49. Stefanac Z., Simon W. In-vitro-verhalten von Makrotetroliden in Membranen alsGrundlage fur hochselelctive Kationenspezifische Electrodensysteme.// Chimia.
1966.V. 20. P. 436-451.50. Umezawa Y., Buhlmann P., Umezawa K., Tohda K., Amemiya S. Potentiometricselectivity coefficients of ion-selective electrodes, part I. Inorganic Cations (TechnicalReport).// Pure Appl. Chem. 2000. V. 72. P. 1851-2082.51. Buhlmann P., Pretsch E., Bakker E. Carrier-Based Ion-Selective Electrodes andBulk Optodes. 2. Ionophores for Potentiometric and Optical Sensors.// Chem. Rev.1998. V. 98. P.
1593-1687.52. Ammann D., Marl W.E., Anker P., Meier P.C., Pretsch E., Simon W. Neutral carrierbased ion-selective electrodes.// Ion-Sel. Electrode Rev. 1983. V. 5. P. 3-92.53. Huser M., Gehrig P.M., Morf W.E., Simon W., Lindner E., Jeney J., Toth K.Membrane technology and dynamic response of ion-selective liquid-membraneelectrodes.// Anal.
Chem. 1991. V. 63. P. 1380-1386.54. Schaller U., Bakker E., Spichiger E., Pretsch E. Ionic additives for ion-selectiveelectrodes based on electrically charged carriers.// Anal. Chem. 1994. V. 66. P. 391-398.55. Morf W. E., The Principles of Ion Selective Electrodes and of Membrane Transport.- Budapest: Akademiai Kiado, 1981. - 432 pages.16056. Koryta J., Ion-Selective Electrodes. – London: Cambridge University Press, 1975. –270 Pages.57. Freiser H., Ion-Selective Electrodes in Analytical Chemistry.
– New York: PlenumPress, 1978. – 141 Pages.58. Bakker E., Buhlmann P., Pretsch E. Carrier-Based Ion-Selective Electrodes andBulk Optodes. 1. General Characteristics.// Chem. Rev. 1997. V. 97. P. 3083-3132.59. Bobacka J., Ivaska A., Lewenstam A. Potentiometric Ion Sensors.// Chem. Rev.2008.
V. 108. P. 329-351.60. Bakker E. Determination of Unbiased Selectivity Coefficients of Neutral CarrierBased Cation-Selective Electrodes.// Anal. Chem. 1997. V. 69. P. 1061-1075.61. Bakker E., Pretsch E. Potentiometric sensors for trace-level analysis // Trends Anal.Chem. 2005. V. 24. P. 199-207.62. Власов Ю.Г., Ермоленко Ю.Е., Колодников В.В., Кадмийселективныеэлектроды на основе смеси сульфидов кадмия и серебра // Журнал Aналит.Xимии.
1981. Т. 36. С. 889-892.63. Власов Ю.Г., Бычков Е.А., Сфаров А.Д., Антонов П.П., Милошова М.С.,Кадмий-селективные халькогенидные стеклянные электроды // Журнал Aналит.Xимии. 1985. Т.40. С. 1438-1446.64. Mourzina Yu. G. , Schöning M. J., Schubert J. ,Zander W. , Legin A. V.
, Vlasov Yu.G., Lüth H. Copper, cadmium and thallium thin film sensors based on chalcogenideglasses. // Anal. Chim. Acta. 2001. V. 433 (1). P. 103-110.65. Guessous A., Sarradin J., Papet P., Elkacemi K. , Belcadi S. ,Pradel A. , Ribes M.Chemical microsensors based on chalcogenide glasses for the detection of cadmiumions in solution. // Sens. Actuat. B. 1998. V.
53 (1-2). P. 13-18.66. Gupta V. K., Kumar P. Cadmium(II)-selective sensors based on Dibenzo-24-Crown8 in PVC matrix.// Anal. Chim. Acta. 1999. V. 389. P. 205–212.67. Gupta V.K. , Chandra S., Mangla R. Dicyclohexano-18-crown-6 as active materialin PVC matrix membrane for the fabrication of cadmium selective potentiometricsensor. // Electrochim. Acta.
2002. V. 47. P. 1579–1586.16168. Gupta V.K.,Jain A.K. , Kumar P. PVC-based membranes of dicyclohexano-24crown-8 as Cd(II) selective sensor. // Electrochim. Acta. 2006. V. 52. P. 736–741.69. Shamsipur M. , Mashhadizadeh M. H. Cadmium ion-selective electrode based ontetrathia-12-crown-4. // Talanta.
2001. V. 53 (5). P. 1065-1071.70. Panwar A., Baniwal S., Sharma C. L., Singh A. K. A polystyrene based membraneelectrode for cadmium(II) ions. // Fresenius J. Anal. Chem. 2000. V. 368. P. 768–772.71. Rezaei B., Meghdadi S., Fazel Zarandi R. A fast response cadmium-selectivepolymeric membrane electrode based on N, N-(4-methyl-1, 2-phenylene) diquinoline-2carboxamide as a new neutral carrier. // J. Haz. Mater. 2008. V 153.
P. 179–186.72. Abbastabar-Ahangar H. , Shirzadmehr A. ,Marjani K. , Khoshsafar H. , Chaloosi M., Mohammadi L. Ion-selective carbon paste electrode based on new tripodal ligand fordetermination of cadmium (II). // J. Incl. Phen. Macrocyc. Chem. 2009. V. 63. P. 287–293.73.Gupta V.K. , Singh A.K. , Gupta B.Schiff bases as cadmium(II) selectiveionophores in polymeric membrane electrodes. // Anal. Chim. Acta. 2007. V. 583. P.340–348.74. Gupta V.K., Jian A.K., Ludwig R., Maheshwari G.