– C. 1279–1284.[62] Hamed H.A. Effective design and implementation of GSS-PLL undervoltage dip and phase interruption/ H.A. Hamed, A.F. Abdou, E. Bayoumi, E.E. ELKholy // IET Power Electronics. – 2018. – № 6 (11). – C. 1018–1028.[63] Hau E. Wind Turbines 3-th ed. / E. Hau – Berlin,2013. – 879 c.[64] Heydt G.T. Applications of the windowed FFT to electric power qualityassessment/ G.T.
Heydt, P.S. Fjeld, C.C. Liu, D. Pierce, L. Tu, G. Hensley // IEEETransactions on Power Delivery. – 1999. – № 4 (14). – C. 1411–1416.[65] Jamma M. Voltage oriented control of three-phase PWM rectifier usingspace vector modulation and input output feedback linearization theory/ M. Jamma,M. Barara, M. Akherraz, B.A. Enache // 2016 8th International Conference onElectronics, Computers and Artificial Intelligence (ECAI).
– 2016. – (30). – C. 1–8.[66] Kadu A.D. Application of STATCOM for harmonic mitigation and powerfactor improvement using direct current control technique / A.D. Kadu, P. Debre,R. Juneja, N. Pande // 2017 Second International Conference on Electrical, Computerand Communication Technologies (ICECCT), 2017. – С.1–4.[67] Karbouj H. A Novel Wind Farm Control Strategy to Mitigate Voltage DipInduced Frequency Excursion/ H. Karbouj, Z.H. Rather // IEEE Transactions onSustainable Energy.
– 2018. – C.1–9.[68] Katic V.A. Novel voltage dip detection algorithm using harmonics in thedip’s transient stage / V.A. Katic, A.M. Stanisavljevic // IECON 2017 - 43rd AnnualConference of the IEEE Industrial Electronics Society, 2017. – С.351–356.[69] Kimbark E.W. Direct Current Transmission 1-th ed. / E.W. Kimbark –Portland,1971. – 508 c.[70] Kolar J.W. The Essence of Three-Phase PFC Rectifier Systems—Part I/J.W. Kolar, T.
Friedli // IEEE Transactions on Power Electronics. – 2013. – № 1 (28). –C. 176–198.[71] Li Y. A resonant modular multilevel DC-DC converter with zero currentswitching for MVDC application / Y. Li, X. Lyu, D. Cao // 2017 IEEE Applied PowerElectronics Conference and Exposition (APEC), 2017. – С.164–169.123[72] Liu Y. Impedance Source Power Electronic Converters 1-th ed./ Y. Liu,H. Abu-Rub, B. Ge, F. Blaabjerg, O. Ellabban, P.C. Loh – Chichester,2016.
– 404 c.[73] Ma L. Voltage Dip Evaluation Index Based on Voltage Dip Matrix/ L. Ma,Q. Zhou // 2017 4th International Conference on Information Science and ControlEngineering (ICISCE). – 2017. – C. 1327–1330.[74] Mohan N. Power electronics 3-th ed./ N. Mohan, T.M. Undeland,W.P. Robbins, K. Murphy – Hoboken,2003. – 792 c.[75] Monteiro L.F.C. Compensation algorithms based on the p-q and CPCtheories for switching compensators in micro-grids / L.F.C. Monteiro, J.L.
Afonso,J.G. Pinto, E.H. Watanabe, M. Aredes, H. Akagi// 2009 Brazilian Power ElectronicsConference, COBEP2009, 2009. – С.32–40.[76] Ngom I. An Improved Control for DC-Link Fluctuation during Voltage Dipbased on DFIG / I. Ngom, S. Member, A. Badara// 2018 9th International RenewableEnergy Congress (IREC), 2018. – С.1–6.[77] Park R.H.
Abridgment of two-reaction theory of synchronous machinesgeneralized method of analysis — Part I// Journal of the A.I.E.E. – 1929. – № 3 (48). –C. 716–727.[78] Perez E. Voltage Event Detection and Characterization Methods: AComparative Study / E. Perez, J. Barros// 2006 IEEE/PES Transmission & DistributionConference and Exposition: Latin America, 2006. – С.1–6.[79] Proakis J. Digital Signal Processing 4-th ed. / J. Proakis – New Jersey,2000.– 1084 c.[80] Qazi S.H.
Review on active filters and its performance with grid connectedfixed and variable speed wind turbine generator / S.H. Qazi, M.W. Mustafa// Renewableand Sustainable Energy Reviews. – 2016. – (57). – C. 420–438.[81] Quang N.P. Vector Control of Three-Phase AC Machines/ N.P. Quang,J. A Dittrich // – Berlin, Heidelberg,2008.
– 346 c.[82] Redondo R.C. Instantaneous active and reactive powers in electrical networktheory: A review of some properties/ R.C. Redondo, N.R. Melchor, M. Redondo,F.R. Quintela // International Journal of Electrical Power and Energy Systems. – 2013. –№ 1 (53). – C.
548–552.[83] Rong C. Analysis of STATCOM for Voltage Dip Mitigation: Master thesis,2004. – 116с.[84] Sadigh A.K. Fast and precise voltage sag detection method for dynamicvoltage restorer ( DVR ) application/K.M. Smedley// Electric Power Systems Research.– 2016. – (130). – C. 192–207.[85] Sanjuan S.L. Voltage Oriented Control of Three ‐ Phase Boost PWMConverters: Master thesis, 2010. – 105с.[86] Santoso S. Power quality assessment via wavelet transform analysis/ S.Santoso, E.J.
Powers, W.M. Grady, P. Hofmann// IEEE Transactions on PowerDelivery. – 1996. – № 2 (11). – C.924–930.[87] Shi Y. Isolated Modular Multilevel DC-DC Converter with DC Fault CurrentControl Capability Based on Current-Fed Dual Active Bridge for MVDC Application/Y. Shi, H. Li // IEEE Transactions on Power Electronics. – 2017. – № MVDC (8993).
–124C.1–17.[88] Shonin O.B. The digital algorithm for fast detecting and identifying theasymmetry of voltages in three- phase electric grids of mechanical engineeringfacilities/ O.B. Shonin, S.B. Kryltcov, N.G. Novozhilov // MEACS2016, 2017. – С.1–6.[89] Taylor P. Mitigation of Voltage Dips and Swells in Grid-connected WindEnergy Conversion Systems Mitigation of Voltage Dips and Swells in Grid- connectedWind Energy Conversion Systems/P.
Taylor, M.N. Eskander, S.I. Amer // IETE Journalof Research. – 2014. – № 6 (57). – C. 515–524.[90] Thorborg K. A Three-Phase Inverter with Reactive Power Control // IEEETransactions on Industry Applications. – 1973. – № 4 (IA-9). – C. 473–481.[91] Torres R.A. Ride-through capability improvement of 30kW DFIG-basedwind turbine under unsymmetrical voltage dip / R.A. Torres, E.F. Cota, V.F. Mendes //2017 Brazilian Power Electronics Conference (COBEP), 2017. – С.1–6.[92] Tsengenes G. A three-level space vector modulated grid connected inverterwith control scheme based on instantaneous power theory/ G.
Tsengenes,T. Nathenas,G. Adamidis // Simulation Modelling Practice and Theory. – 2012. – (25). – C.134–147.[93] Uhlmann E. Power Transmission by Direct Current 1-th ed. / E. Uhlmann –Berlin,1975. – 389 c.[94] Varma D.K. Voltage Oriented Controller based Statcom in Grid Connectedwind Energy system Under Unbalaced and Distorted Conditions // Smart Structures andSystems (ICSSS), 2014 International Conference, 2014. – С.55–58.[95] Vas P. Sensorless Vector and Direct Torque Control / P. Vas – Oxford,1998.–729 c.[96] Wang Y.
Single-Event Characteristics for Voltage Dips in Three-PhaseSystems/ Y. Wang, A. Bagheri, M.H.J. Bollen, X.Y. Xiao // IEEE Transactions onPower Delivery. – 2017. – № 2 (32). – C.832–840.[97] Watanabe E.H. Instantaneous p-q Power Theory for Control ofCompensators in Micro-Grids/E.H. Watanabe, M. Aredes, J.L. Afonso, J.G. Pinto,L.F.C. Monteiro, H. Akagi // 2010 International School on Nonsinusoidal Currents andCompensation. – 2010. – C.17–26.[98] Weldemariam L. Regulation and classification of voltage dips /L.
Weldemariam, V. Cuk, S. Cobben, J. Van Waes 2017. – С.832–836.[99] Weldemariam L.E. Experimental investigation on the sensitivity of anindustrial process to voltage dips/ L.E. Weldemariam, H.J. Gartner, V. Cuk,J.F.G. Cobben, W.L. Kling // 2015 IEEE Eindhoven PowerTech, PowerTech 2015. –2015.[100] Weldemariam L.E. Weighting factors for estimating the economic impactof voltage dips /L.E. Weldemariam, V.
Cuk, J.F.G. Cobben // 2016 IEEE InternationalConference on Power System Technology (POWERCON), 2016. – С.1–6.[101] Zarif M. Step-by-step design and tuning of VOC control loops for gridconnected rectifiers/M. Zarif, M. Monfared // International Journal of Electrical Power& Energy Systems. – 2015. – (64). – C. 708–713.[102] Zhang Y. Direct power control of PWM rectifier under unbalanced networkusing extended power theory /Y.
Zhang, J. Liu, J. Gao // 2017 IEEE Energy Conversion125Congress and Exposition (ECCE), 2017. – С.4617–4621.[103] Zyl A. Van Voltage Sag Ride-Through for Adjustable Speed Drives withActive Rectifiers /A. Zyl, R. Spee, A. Faveluke, S. Bhowmik // IEEE IndustryApplications Society Annual Meeting, 1997. – С.486–492.126ПРИЛОЖЕНИЕ 1Диаграммы напряжений, подаваемых на вход экспериментальной установкиВ ходе эксперимента напряжения фиксировались при различном уровненесимметрии, для этого напряжение в одной из фаз снижалось с помощьюлабораторного автотрансформатора. Всего было рассмотрено шесть различныхрежимов работы системы: нормальное напряжение (все действующие значенияфазных напряжений равны 25 В), при снижении напряжения на 20% (напряжениеодной из фаз равно 20 В), а также при снижении напряжения на 40%, 60%, 80% и96%.Рисунок 1 – Напряжения трехфазной сети при работе в симметричном режимеРисунок 2 – Напряжения трехфазной сети при однофазном провале напряженияглубиной 20%Рисунок 3 – Напряжения трехфазной сети приоднофазном провале напряжения глубиной 40%Рисунок 4 – Напряжения трехфазной сети приоднофазном провале напряжения глубиной 60%Рисунок 5 – Напряжения трехфазной сети приоднофазном провале напряжения глубиной 80%Рисунок 6 – Напряжения трехфазной сети приоднофазном провале напряжения глубиной 96%128ПРИЛОЖЕНИЕ 2Зависимости ошибки определения параметров напряжений трехфазнойсети от количества сделанных измеренийРисунок 7 – Зависимости, полученная при нормальном напряженииРисунок 8 – Зависимости при понижении напряжения в одной фазе на 20%Рисунок 9 – Зависимости при понижении напряжения вРисунок 11 – Зависимости при понижении напряжения водной фазе на 40%одной фазе на 80%Рисунок 10 – Зависимости при понижении напряжения вРисунок 12 – Зависимости при понижении напряжения водной фазе на 60%одной фазе на 96%130ПРИЛОЖЕНИЕ 3Сравнение результатов работы итерационного алгоритма, работающегопо критерию минимума ошибки определения частоты, сдействительными напряжениями трехфазной сетиАлгоритмопределенияпараметровпрямойиобратнойпоследовательности напряжений трехфазной сети по критерию допустимойошибки определения частоты был опробован на всех имеющихся массивахвходных данных.