Interactive Catalog Replaces Catalog PagesHoneywell Sensing and Control has replacedthe PDF product catalog with the newInteractive Catalog. The Interactive Catalog isa power search tool that makes it easier to findproduct information. It includes moreinstallation, application, and technicalinformation than ever before.Sensing and ControlHoneywell Inc.11 West Spring StreetFreeport, Illinois 61032Click this icon to try the newInteractive Catalog.Temperature SensorsPlatinum RTDsHEL-700FEATURES1 Linear resistance vs temperature1 Accurate and Interchangeable1 Excellent stability1 Small for fast response1 Wide temperature range1 3-packaging optionsHEL-700 Thin Film Platinum RTDs (Resistance Temperature Detectors) provideexcellent linearity, accuracy, stability andinterchangeability.
Resistance changeslinearly with temperature. Laser trimmingprovides ±0.3°C interchangeability at25°C.TYPICAL APPLICATIONS1 HVAC - room, duct and refrigerantequipment1 Electronic assemblies - thermal management, temperature compensation1 Process control - temperature regulation1000V, 375 alpha provides 10X greatersensitivity and signal-to-noise.
Both1000V and 100V provide interchangeabilities of ±0.6°C or better from -100°C to100C, and ±3.0°C at 500°C.MOUNTING DIMENSIONS (for reference only)HEL-700 Ribbon LeadORDER GUIDEHEL-700Thin Film Platinum RTD-U-T1000V, 0.00375 V/V/°C100V, 0.00385 V/V/°C DIN Standard-0-1±0.2% Resistance Trim (Standard)±0.1% Resistance Trim (Optional)-ARadial Ribbon Lead-BRadial Chip-CSMT Axial Flip Chip (1000VONLY)Fig. 1: Linear Output VoltageHEL-700 Radial ChipHoneywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada85TemperatureFig. 2: Adjustable Point (Comparator) InterfaceHEL-700 SMT (Axial) Flip ChipTemperature SensorsPlatinum RTDsHEL-700FUNCTIONAL BEHAVIORRT J R0(1+AT+BT2−100CT3+CT4)RT J Resistance (V) at temperature T (°C)R0 J Resistance (V) at 0°CT J Temperature in °CAJa+ adBJ −adCT<0 J − a b10010021004CONSTANTSAlpha, a (°C-1)0.00375±0.0000290.003850±0.000010Delta, d (°C)1.605 ± 0.0091.4999 ± 0.007Beta, b (°C)0.160.10863A (°C )3.81×103.908×10B (°C-2)−6.02×10-7−5.775×10-7C (°C-4)−6.0×10-12−4.183×10-12-1-3ACCURACY VS TEMPERATUREHEL-700 platinum RTDs are available in two base resistance trimtolerances: ±0.2% or ±0.1%.
The corresponding resistanceinterchangeability and temperature accuracy for these tolerances are:ToleranceStandard ±0.2%Optional ±0.1%Temperature(°C)±DR*(V)±DT(°C)±DR*(V)±DT(°C)−2006.81.65.11.2-3Both b J 0 and C J 0 for T>0°CRESISTANCE VS TEMPERATURE CURVE−1002.90.82.40.602.00.51.00.31002.90.82.20.62005.61.64.31.23008.22.46.21.840011.03.28.32.550012.54.09.63.060015.14.810.43.3*1000V RTD. Divide DR by 10 for 100V RTD.CAUTIONPRODUCT DAMAGEThe inherent design of this component causes it to be sensitiveto electrostatic discharge (ESD). To prevent ESD-induceddamage and/or degradation, take normal ESD precautionswhen handling this product.SPECIFICATIONSSensor TypeThin film platinum RTD;R0 J 1000 V @ 0°C; alpha J 0.00375 V/V/°CR0 J 100 V @ 0°C; alpha J 0.00385 V/V/°CTemperature Range−200 to +540°C (−300 to +1000°F)Temperature Accuracy±0.5°C or 0.8% of temperature, °C (R0 ±0.2% trim), whichever is greater±0.3°C or 0.6% of temperature, °C (R0 ±0.1% trim), whichever is greater (optional)Base Resistance andInterchangeability, R0 ± DR01000 ± 2 V (±0.2%) @ 0°C1000 ± 1 V (±0.1%) @ 0°C (optional)Linearity±0.1% of full scale for temperatures spanning −40° to +125°C±2.0% of full scale for temperatures spanning −200° to +540°CTime Constant<0.15 seconds in water @ 3 ft./sec.<1 second on metal surfaces: <4 seconds in air @ 10 ft./sec.Operating Current2 mA max.
For self-heating errors of 1°C1 mA recommendedStabilityBetter than 0.25°C/year: 0.05°C/5 years for occupied environmentsSelf-Heating0.3 mW/°CInsulation Resistance>50 MV @ 50 VDC @ 25°CCase Material99% alumina support, vapor deposited alumina passified resistance portion, refractory glasspassified overallLead Material – RibbonPlatinum ribbon, 0.002 × 0.010 × 0.16 in. long nominalLead Pull Strength – Ribbon200 grams nominal pulling up from surface86Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 CanadaTemperature SensorsPlatinum RTDsHEL-700 SeriesFEATURES1 Linear resistance vs temperature1 Accurate and Interchangeable1 Excellent stability1 Teflon or fiberglass lead wires1 Wide temperature range1 Ceramic case materialTYPICAL APPLICATIONS1 HVAC – room, duct and refrigerantequipment1 Instrument and probe assemblies –temperature compensation1 Process control – temperatureregulationORDER GUIDEHEL-70528 ga.
TFE Teflon, 2-wire only28 ga. Fiberglass, 2-wire onlyHEL-71128 ga. TFE Teflon (2-wire 1000V, 3-wire 100V)HEL-71228 ga. Fiberglass (2-wire 1000V, 3-wire 100V)HEL-71624 ga. TFE Teflon (2-wire 1000V, 3-wire 100V)HEL-71724 ga. Fiberglass (2-wire 1000V, 3-wire 100V)-UThe 1000V, 375 alpha version, provides10X greater sensitivity and signal-tonoise. Optional NIST calibrations improve accuracy to ±0.03°C at 0°C.Fig.
1: Wheatstone Bridge 2-Wire InterfaceHEL-707-THEL-700 Series elements are fully assembled, ready to use directly or in probeassemblies without the need for fragilesplices to extension leads.1000V, 0.00375 V/V/°C100V, 0.00385 V/V/°C DIN Standard-0±0.2% Resistance Trim (Standard)-1±0.1% Resistance Trim (Optional)-12Fig. 2: Linear Output VoltageLead wire length, 12 inches-00No NIST calibration-C1NIST @ 0°C-C2NIST @ 0 & 100°C-C3NIST @ 0, 100 & 260°CFig. 3: Adjustable Point (Comparator) InterfaceCAUTIONPRODUCT DAMAGEThe inherent design of this component causes it to be sensitiveto electrostatic discharge (ESD).
To prevent ESD-induceddamage and/or degradation, take normal ESD precautionswhen handling this product.Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada87TemperatureMOUNTING DIMENSIONS (for reference only)Temperature SensorsPlatinum RTDsHEL-700 SeriesFUNCTIONAL BEHAVIORRT J R0(1+AT+BT2−100CT3+CT4)RT J Resistance (V) at temperature T (°C)R0 J Resistance (V) at 0°CT J Temperature in °CAJa+adBJ−adCT<0 J − a b10010021004ACCURACY VS TEMPERATUREStandard ±0.2%Optional ±0.1%Temperature(°C)Tolerance±DR*(V)±DT(°C)±DR*(V)±DT(°C)−2006.81.65.11.2CONSTANTS−1002.90.82.40.602.00.51.00.31002.90.82.20.65.61.64.31.2Alpha, a (°C )0.00375±0.0000290.003850±0.0000102003008.22.46.21.8Delta, d (°C)1.605 ± 0.0091.4999 ± 0.00740011.03.28.32.5Beta, b (°C)0.160.1086350012.54.09.63.0A (°C )3.81×103.908×1060015.14.810.43.3B (°C-2)−6.02×10-7−5.775×10-7C (°C-4)−6.0×10-12−4.183×10-12-1-1-3-3Both b J 0 and C J 0 for T>0°CRESISTANCE VS TEMPERATURE CURVE*1000V RTD.
Divide D by 10 for 100V RTD.NIST CALIBRATIONNIST traceable calibration provides resistance readings at 1, 2 or3 standard temperature points to yield a resistance versus temperature curve with 10x better accuracy.Calibration1 Point2 Point3 PointT (°C)±DT (°C)±DT (°C)±DT (°C)-2000.9——-1000.50.270.1500.030.030.031000.40.110.072000.80.20.083001.20.336.24001.60.58.35002.00.89.66002.61.210.4SPECIFICATIONSSensor TypeThin film platinum RTD;R0 J 1000 V @ 0°C; alpha J 0.00375 V/V/°CR0 J 100 V @ 0°C; alpha J 0.00385 V/V/°CTemperature RangeTFE Teflon: −200° to +260°C (−320° to +500°F)Fiberglass: −75° to +540°C (−100° to +1000°F)Temperature Accuracy±0.5°C or 0.8% of temperature, °C (R0 ±0.2% trim), whichever is greater±0.3°C or 0.6% of temperature, °C (R0 ±0.1% trim), whichever is greater (optional)Base Resistance andInterchangeability, R0 ± DR01000 ± 2 V (±0.2%) @ 0°C1000 ± 1 V (±0.1%) @ 0°C (optional)Linearity±0.1% of full scale for temperatures spanning −40° to +125°C±2.0% of full scale for temperatures spanning −75° to +540°CTime Constant<0.5 sec.
0.85 inch O.D. in water at 3 ft/sec; <1.0 sec, 0.85 inch O.D. in still waterOperating Current2 mA maximum for self heating errors of <1°C; 1 mA recommendedStability<0.25°C/year; 0.05°C per 5 years in occupied environmentsSelf Heating<15 mW/°C for 0.85 O.D. typicalInsulation Resistance>50 MV at 50 VDC at 25°CConstructionAlumina case; Epoxy potting (Teflon leads); Ceramic potting (fiberglass leads)Lead MaterialNickel coated stranded copper, Teflon or Fiberglass insulated88Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada.
Характеристики
Тип файла PDF
PDF-формат наиболее широко используется для просмотра любого типа файлов на любом устройстве. В него можно сохранить документ, таблицы, презентацию, текст, чертежи, вычисления, графики и всё остальное, что можно показать на экране любого устройства. Именно его лучше всего использовать для печати.
Например, если Вам нужно распечатать чертёж из автокада, Вы сохраните чертёж на флешку, но будет ли автокад в пункте печати? А если будет, то нужная версия с нужными библиотеками? Именно для этого и нужен формат PDF - в нём точно будет показано верно вне зависимости от того, в какой программе создали PDF-файл и есть ли нужная программа для его просмотра.