Диссертация (1024691), страница 41
Текст из файла (страница 41)
Magnetoencephalography. In: Encyclopedia ofNeuroscience. 2004. Adelman G., Smith B., editors Elsevier, 1st, 2nd and 3rd editions.1816 c.7. Sternickel K., Braginski A.I. Biomagnetism using SQUIDs: status and perspectives// Supercond. Sci. Technol. 2006. V. 19. P. 160–171.8. Cohen D., Kaufman L.A. Magnetic determination of the relationship between theS-T segment shift and the injury current produced by coronary artery occlusion //Circulation Res. 1975. V. 36.
P. 414–424.9. Wikswo, J.P., Jr., Barach J.P. Possible sources of new information in themagnetocardiogram // J. Theoretical. Biol. 1982. V. 95. P. 721–729.10. Wikswo J. P., Jr. Theoretical aspects of ECG-MCG relationship // inBiomagnetism, An Interdisciplinary Approach, S. J. Williamson, G.-L. Romani, L.Kaufman and I. Modena, Eds., New York: Plenum Press.
1983. P. 311–326.11. Complementary nature of electrocardiographic and magnetocardiographic data inpatients with ischemic heart disease / J. Lant [et al.]. J. Electrocardiography. 1990.V.23. P. 315–322.27912. Magnetic field and body surface potential mapping of patients with venticulartachycardia in Biomagnetism: Clinical Aspects / G. Stroink [et al.]. M.
Hoke, S.N. Erne,Y.C. Okada, and G.L. Romani, Eds. Amsterdam: Elsevier. 1992. P. 471–475.13.FeniciR.,BrisindaD.,MeloniA.M.Clinicalapplicationsofmagnetocardiography // Expert Rev. Mol. Diagn. 2005. V. 5, No 3. P. 291–313.14. Microtesla MRI with dynamic nuclear polarization / V.S. Zotev [et al.]. Journal ofMagnetic Resonance.
2010. No. 207. P. 78–88.15. Co-registration of interleaved MEG and ULF MRI using a 7 channel low-TcSQUID system / P.E. Magnelind [et al.]. IEEE Trans. on Appl. Supercond. 2011. V. 21,No. 3. P. 456–460.16. Flynn E.R. and Bryant H.C. A biomagnetic system for in vivo cancer imaging //Phys.
Med. Biol. 2005. V. 50. P. 1273–1293.17. Subfemtotesla multichannel atomic magnetometer / I.K. Kominis [et al.]. Nature.2003. No. 422. P. 596–599.18. Кнеппо П., Титомир Л.И. Биомагнитные измерения. М.: Энергоатомиздат.1989. 286 с.19. Clarke J.
SQUID Handbook. J. Clarke and A. I. Braginski (ed). V. I. Berlin:Wiley-VCH. 2004. 395 c. / J. Clarke and A. I. Braginski (ed). V. II. Weinheim: WileyVCH. 2006. 634 c.20. Weinstock H. SQUID Sensors: Fundamentals, Fabrication and Applications. H.Weinstock (ed). Dordrecht: Kluwer-Academic. 1995. 400 c.21. Зудбинов Ю.И. Азбука ЭКГ.
Издание 3. Ростов-на-Дону: «Феникс».2003. 160 с.22. Дощицин В.Л. Практическая электрокардиография. 2-е изд., перераб. и доп.М.: Медицина. 1987. 336 с.23. Дехтярь Г.Я. Электрокардиографическая диагностика. 2-е изд., перераб. идоп. М.: Медицина. 1972. 416 с.24.ЗенковЛ.Р.Клиническаяэлектроэнцефалографияэпилептологии). 3-е изд. М.: МЕДпресс-информ. 2004. 368 с.(сэлементами28025. Хорнак, Дж. П. Основы МРТ // cis.rit.edu: сервер Rochester Institute ofTechnology. 1996-99.
URL http://www.cis.rit.edu/htbooks/mri/inside-r.htm (датаобращения 02.17.2009).26. Lauterbur P.C. All science is interdisciplinary — from magnetic moments tomolecules to men // Les Prix Nobel. The Nobel Prizes 2003. Nobel Foundation. 2004. Р.245–251.27. Mansfield P. Snap-shot MRI // Les Prix Nobel. The Nobel Prizes 2003. NobelFoundation. 2004.
Р. 266–283.28. Fagaly, R. Custom-Made Systems of Tristan Technologies, Inc. // 2005.неопубликовано.29. Seki Y., Kandori A. and Suzuki D. Open type magnetocardiograph withcylindrical magnetic shield // Appl. Phys. Lett. 2005. V. 86. P. 243902.30.VrbaJ.,RobinsonS.E.SQUIDsensorarrayconfigurationsformagnetoencephalography applications // J. Supercond. Sci. Technol. 2002. V. 15. R.51–89.31. Lima E., Irimia A.
and Wikswo J.P. The magnetic inverse problem // The SQUIDHandbook (ed. by J. Clarke and A. I. Braginski (Berlin: Wiley-VCH). 2006. V. II. P.139–267.32. Comon P. Independent component analysis, a new concept // Signal Process.1994. V. 36, No 3. P. 287–314.33. Cardoso, J-F. Blind signal separation: statistical principles // Proc. of the IEEE.1998. V. 86, No.
10. P. 2009–2025.34. Independent component analysis: fetal signal reconstruction from MCGrecordings / S. Comani [et al.]. Comput. Methods Programs Biomed. 2004. V. 75, No.2. P. 163–177.35. Taulu S., Kajola M. and Simola Ju. Suppression of interference and artefacts bythe signal space separation method // J. Brain Topography. 2004. V. 16, No. 4. P.
269–275.36. Burrus C.S., Copinath R.A. and Guo H. Wavelets and Wavelet Transforms, aPrimer // Englewood Cliffs. NJ.: Prentice-Hall. 1998. 267 c.28137. Nonlinear noise reduction using reference data / K. Sternickel [et al.]. Phys. Rev.E. 2001. V. 63, No. 2. P. 036209.38. Schmidt, R.O. Multiple emitter location and signal parameter-estimation // IEEETrans. Antennas Propag.
1986. V. 34, No. 3. P. 276–280.39. Mosher J.C., Lewis P.S. and Leahy R.M. Multiple dipole modeling andlocalization from spatio-temporal MEG data // IEEE Trans. Biomed. Eng. 1992. V. 39,No. 6. P. 541–557.40. Vrba J., Nenonen J. and Trahms L. Biomagnetism. In The SQUID Handbook vol.II, ed J. Clarke and A. I. Braginski (Berlin: Wiley-VCH). 2006. Р. 269–389.41. Dössel O. Inverse problem of electro- and magnetocardiography: review andrecent progress // ijbem.org: сервер International Journal of Bioelectromagnetism.2000.URLhttp:www.ijbem.org/volume2/number2/doessel.(датаобращения17.10.2014).42.
Modeling the anatomy of the human heart using the cryosection images of theVisible Female dataset / F.B. Sachse [et al.]. Proc. of the 3rd Users Conf. of theNational Library of Medicine's Visible Human Project. (Bethesda, USA, 2000). 2000.43. Hamalainen M.S. and Ilmoniemi R.J. Interpreting magnetic fields of the brain minimum norm estimates // Med. Biol. Eng. Comput. 1994.
V. 32. P. 35–42.44. Gorodnitsky I.F., George S.G. and Rao B.D. Neuromagnetic source imaging withfocus — a recursive weighted minimum norm algorithm // Encephalogr. Clin.Neurophys. 1995. V. 95. P. 231–251.45. Non-fluoroscopic localisation of an amagnetic stimulation catheter bymultichannel magnetocardiography / R. Fenici [et al.]. Pacing Clin. Electrophysiol.1999. V. 22, № 8.
P. 1210–1220.46. High resolution magnetic images of planar wave fronts reveal bidomainproperties of cardiac tissue / J.R. Holzer [et al.]. Biophys. Jour. 2004. V. 87. P. 4326–4332.47. Vrba J. Multichannel SQUID biomagnetic systems // Applications ofSuperconductivity ed. H.Weinstock (Dordrecht: Kluwer-Academic).
2000. P. 61–138.28248. Vrba J. and Robinson S. E. Signal processing in magnetoencephalography //Methods. 2001. V. 25, No. 2. P. 249–271.49. BabySQUID: A mobile, high-resolution multichannel magnetoencephalographysystem for neonatal brain assessment / Y. Okada [et al.]. Rev. of Scient. Instr. 2006. V.77. P. 024301–1–9.50.
Preissl H. Lowery C.L. and Eswaran H. Fetal magnetoencephalography: currentprogress and trends // Exp. Neurol. 2004. V. 190. P. S 28–36.51. Magnetocardiography predicts coronary artery disease in patients with acute chestpain / J-W. Park [et al.]. Ann. Noninv. Electrocardiol.
2005. V. 10. P. 312–323.52. Resting Magnetocardiography Accurately Detects Myocardial Ischemia in ChestPain Patients Even When 12 Lead ECG is Normal / K. Tolstrup [et al.]. Circulation.2004. V. 110. P. III–743.53. Macfarlane P.W. Comprehensive Electrocardiology. Theory and Practice inHealth and Disease. P.W. Macfarlane, T.D.W. Lawrie (eds.) (Vols 1-3) New York:Pergamon Press.
1989. 1785 c.54. Magnetocardiography and 32-lead potential mapping: repolarization in normalsubjects during pharmacologically induced stress / K. Brockmeier [et al.]. J. Cardiovasc.Electrophysiol. 1997. V. 8, No. 6. P. 615–626.55. Physical aspects of cardiac magnetic fields and electric potentials / O. Kosch [etal.].
Biomag 2000: Proc. of 12th Int. Conf. on Biomagnetism, ed. J. Nenonen, R.J.Ilmoniemi and T. Katila (Espoo, Finland: Helsinki University of Technology). 2001. P.553–556.56. MCG to ECG source differences: measurements and a two-dimensional computermodel study / R. Weber Dos Santos [et al.]. J. Electrocardiol. 2004. V.
37. P. 123–127.57. Use of Machine Learning for Classification of Magnetocardiograms, / M.Embrechts [et al.]. Proc. IEEE Conference on System, Man and Cybernetics,Washington DC. 2003. P. 1400–1405.58. Embrechts M. Szymanski B. and Sternickel K. Introduction to Scientific DataMining: Direct Kernel Methods & Applications // Computationally Intelligent Hybrid283Systems: The Fusion of Soft Computing and Hard Computing, Wiley New York. 2005.P.
317–365.59. Drung D. The PTB 83 SQUID system biomagnetic applications in a clinic // IEEETrans. Appl. Supercond. 1995. V. 5. P. 2112–2117.60. Nenonen J. Montonen J., Koskmen R. Surface gradient analysis of atrialactivation from magnetocardiographic maps // Int. J. Bioelecfromagnetism. 2003. V. 5,No. 1. P 98–99.61. 67 channel biomagnetometer designed for cardiology and other applications /P.Van Leeuwen [et al.]. Recent Advances in Biomagnetism. Yoshimoto T., Kotani M.,Kuriki S., Karibe H., Nakasato N.