For usage of expressions (1) - (7) it is made table of calculated-informational data (table 2).
Table of calculated-informational data. Table 2
№ | Parameters and features | System components diagnoses | Sq | I | |||||||
D1 | D2 | D3 | D4 | D5 | D6 | ||||||
1 | X1 | 0.25 | 0 | 0 | 0 | 0 | 0 | 0,25 | 0.81 | ||
2 | X1 | 0 | 0.31 | 0 | 0 | 0 | 0 | 0,31 | 0.88 | ||
3 | X1 | 0.25 | 0.31 | 0 | 0 | 0 | 0 | 0.56 | 0.98 | ||
4 | X2 | 0.25 | 0 | 0 | 0 | 0 | 0 | 0.25 | 0.81 | ||
5 | X2 | 0 | 0 | 0 | 0 | 0.13 | 0 | 0.13 | 0.55 | ||
6 | X2 | 0.25 | 0 | 0 | 0 | 0.13 | 0 | 0.38 | 0.95 | ||
7 | X3 | 0 | 0 | 0. 19 | 0 | 0 | 0 | 0. 19 | 0.69 | ||
8 | X3 | 0 | 0 | 0 | 0.06 | 0 | 0 | 0.06 | 0.32 | ||
9 | X3 | 0 | 0 | 0. 19 | 0.06 | 0 | 0 | 0.25 | 0.81 | ||
10 | X4 | 0 | 0 | 0 | 0 | 0 | 0.06 | 0.06 | 0.32 | ||
11 | X5 | 0 | 0 | 0 | 0 | 0.13 | 0 | 0.13 | 0.55 |
Algorithm for checking of aggregate state. Table 3
№ row | Sq | I | ||||||||
D1 | D2 | D3 | D4 | D5 | D6 | |||||
1 | 0.25 | 0 | 0 | 0 | 0 | 0 | 0,25 | 0.81 | ||
2 | 0 | 0.31 | 0 | 0 | 0 | 0 | 0,31 | 0.88 | ||
3 | 0.25 | 0.31 | 0 | 0 | 0 | 0 | 0.56 | 0.98 | ||
4 | 0.25 | 0 | 0 | 0 | 0 | 0 | 0.25 | 0.81 | ||
5 | 0 | 0 | 0 | 0 | 0.13 | 0 | 0.13 | 0.55 | ||
6 | 0.25 | 0 | 0 | 0 | 0.13 | 0 | 0.38 | 0.95 | ||
7 | 0 | 0 | 0. 19 | 0 | 0 | 0 | 0. 19 | 0.69 | ||
8 | 0 | 0 | 0 | 0.06 | 0 | 0 | 0.06 | 0.32 | ||
9 | 0 | 0 | 0. 19 | 0.06 | 0 | 0 | 0.25 | 0.81 | ||
10 | 0 | 0 | 0 | 0 | 0 | 0.06 | 0.06 | 0.32 | ||
11 | 0 | 0 | 0 | 0 | 0.13 | 0 | 0.13 | 0.55 |
# | D1 | D2 | Sq | I |
1 | 0.44 | 0.44 | 0.98 | |
2 | 0.55 | 0.55 | 0.99 | |
4 | 0.44 | 0.44 | 0.98 | |
5 | 1.00 | 0 | ||
6 | 0.44 | 0.44 | 0.98 | |
7 | 1.00 | 0 | ||
8 | 1.00 | 0 | ||
9 | 1.00 | 0 | ||
10 | 1.00 | 0 | ||
11 | 1.00 | 0 |
# | D3 | D4 | D5 | D6 | Sq | I |
1 | 1.00 | 0 | ||||
2 | 1.00 | 0 | ||||
4 | 1.00 | 0 | ||||
5 | 0.29 | 0.29 | 0.86 | |||
6 | 0.29 | 0.29 | 0.86 | |||
7 | 0.43 | 0.43 | 0.98 | |||
8 | 0.13 | 0.13 | 0.56 | |||
9 | 0.43 | 0.13 | 0.56 | 0.99 | ||
10 | 0.13 | 0.13 | 0.56 | |||
11 | 0.29 | 0.29 | 0.86 |
# | D5 | D6 | Sq | I |
1 | 1.00 | 0 | ||
2 | 1.00 | 0 | ||
4 | 1.00 | 0 | ||
5 | 0.65 | 0.65 | 0.93 | |
6 | 0.65 | 0.65 | 0.93 | |
7 | 1.00 | 0 | ||
8 | 1.00 | 0 | ||
10 | 0.29 | 0.29 | 0.86 | |
11 | 0.65 | 0.65 | 0.93 | |
# | D3 | D4 | Sq | I |
1 | 1.00 | 0 | ||
2 | 1.00 | 0 | ||
4 | 1.00 | 0 | ||
5 | 1.00 | 0 | ||
6 | 1.00 | 0 | ||
7 | 0.76 | 0.76 | 0.79 | |
8 | 0.23 | 0.23 | 0.76 | |
10 | 1.00 | 0 | ||
11 | 1.00 | 0 |
Description of obtained algorithm
So, using this algorithm of malfunctions discovering we can compose an order of system checking, namely, steps of inspection (diagnostics). These steps are:
1. Check internal cavity of air-to-air heat exchanger
2. Check correctness of tubes installation
3. Check fittings of air-cycle machine
4. Inspect noise suppression device housing for cracks
5. Inspect places of pipeline and other aggregates mounting
6. Check correctness of installation
List of abbreviations:
1. ACS - air conditioning system
2. AAHE - air-to-air heat exchanger
3. ACM - air-cycle machine
4. NSD - noise suppression device.